Mircom CAT-5622 -DM-1008A - Eight Initiating Circuit Module
File Preview
Click below to download for free
Click below to download for free
File Data
Name | mircom-cat-5622-dm-1008a-eight-initiating-circuit-module-2856739401.pdf |
---|---|
Type | |
Size | 819.74 KB |
Downloads |
Text Preview
EIGHT INITIATING CIRCUIT MODULE Class B Style B or 4 Class A Style Initiating Circuits which can be con gured Alarm Supervisory Water ow or Trouble Alarm Supervisory and Trouble provided for individual annunciation of zone labels for zone identi cation as Supervisory Circuit for and Non Latching circuits are power limited for use with limited cable terminal blocks for ease of wiring servicing transient protection on all circuits DM 1008A consists of a PC board which at the bottom of the chassis The PC board connected via cables to the board on the main Space is provided on the dress panel the application of slide in labels for initiating description Labels are provided with each Removable terminal blocks are provided for connection of eld wiring and servicing DM 1008A Module provides the FA 1000 or Series Fire Alarm Control panels with to 8 Class B Style B or 4 Class A Style D Circuits which can be con gured for Alarm Water ow or Trouble circuits DM 1008A provides up to eight zones of Class Style B or four Class A Style D Initiating circuits of the circuits can be con gured as either Supervisory Water ow or Trouble zones circuit can handle both powered devices such smoke detectors and non powered devices such heat detectors pull stations water ow devices switches etc reserves the right to make changes at any time without notice in prices colours materials components equipment speci cations and models and also to discontinue models TO BE USED FOR INSTALLATION PURPOSES NUMBER Wiring Diagram B D B D B D INITIATING CIRCUIT 1 ZONE POWER LIMITED INITIATING CIRCUIT 2 OR WATERFLOW ZONE POWER LIMITED B D INITIATING CIRCUIT 2 ZONE SEE STYLE D NOTE POWER LIMITED B B D AVAIL FA 1012K CIRCUITS TO 8 ARE NOT AVAIL FA 1012K D NOTE INITIATING CIRCUITS IN A SERIES 1000 BE ALL EITHER STYLE B OR D STYLE D IS SELECTED THE OF CIRCUITS IS CUT IN HALF SEE APPENDIX FOR COMPATIBLE DEVICES DETECTOR DETECTOR OR NO STATION 1 2W ELR LISTED S5434 MP 300 MANUFACTURED MIRCOM POWER LIMITED CIRCUITS MUST USE TYPE FPL FPLR FPLP POWER LIMITED CABLE CIRCUITS ARE FULLY SUPERVISED AND RATED 22 VDC 3 mA STANDBY 5 mV RIPPLE 50 mA MAX THEY MAY BE CONFIGURED AS REQUIRED THE THRESHOLD IS 21 mA MAXIMUM LOOP IS 100 OHMS 50 OHMS PER SIDE Speci cations Voltage 22 VDC Current 80 mA Standby Current 3 mA of Line Resistor 3.9K ohm W TO BE USED FOR INSTALLATION PURPOSES by Interchange Way Ontario L4K 5W3 905 660 4655 905 660 4113 Witmer Industrial Estates Falls NY 14305 Free 888 660 4655 Toll Free 888 660 4113 page http www mircom com Email mail mircom com 5622 5