Mircom CAT-5635 BPS-1100 Signal Booster Power Supply (English)

File Preview
File Preview
Click below to download for free

Text Preview

SIGNAL BOOSTER POWER SUPPLY Four 4 Class A B Style Z Y Indicating Circuits individual trouble indicators 1.7 Amps per circuit Each Indicating Circuit can be configured as Temporal Code California Code or Time Alert Four supervised programmable contact inputs Circuits may be individually by a DIP switch Auxiliary relay contacts for Booster Ground and Common Trouble Each relay Form C 28 VDC 1 Amp Easy configuration via push buttons and DIP on the front panel Extensive Transient Protection Supports supervised and non supervised suite Amp maximum unregulated output circuits can be expanded up to with two SGM 1004A Regulated auxiliary 24VDC Output 1.7 Amp Space for 6 to 17 AH battery indicating circuits on the BPS 1100 can be for Alarm Silenceable Evacuation 2nd Silenceable or Strobe Non Silenceable and to the programmable contact inputs indicating circuits can be configured for the audible signal rates Steady Temporal California Code or March Time Alert BPS 1100 is enclosed in a beige colour cabinet comes with a durable CAT 30 lock and key BPS 1100 contains its own battery charger of charging up to 17 AH batteries The provides space to mount up to 17 AH Gel batteries BPS 1100 Signal Booster Power Supply is to extend the power capabilities of existing circuits and to provide power for other devices The BPS 1100 may be connected any ULC Listed Fire Alarm Control Panel to provide circuit expansion BPS 1100 consists of four indicating circuits can be expanded up to twelve with the addition two SGM 1004A Four Indicating Circuit Module indicating circuit is rated at 1.7 Amp maximum a total output capacity of 11 Amps The outputs be configured as four Class A B Style Z Y BPS 1100 will also support additional relay with the addition of the RM 1008A Eight Relay Module The RM 1008A is normally used for multiple BPS 1100 units BPS 1100 provides four supervised contact inputs trouble and local detection output contacts and support for and non supervised suite isolators reserves the right to make changes at any time without notice in prices colours materials components equipment specifications and models and also to discontinue models TO BE USED FOR INSTALLATION PURPOSES NUMBER Consumption 200 mA Alarm 350 mA Dimensions x 14 x 4 Space to two 17 AH batteries Relays resistive loads Ground Form C 1 Amp 28 VDC Trouble Form C 1 Amp 28 VDC Line Voltage 60Hz 240V 50Hz Amps 1Amp primary Supply Ratings Amps max secondary Indicating Circuits unfiltered 11 Amps max Gel Cell Sealed Lead Acid Capability AH batteries Information Booster Power Supply Modules Class A B Style Z Y Indicating Circuit Module Rated at 1.7 Amps per circuit Relay Circuit Module Form C relays rated for 28 VDC 1 Amp max per circuit TO BE USED FOR INSTALLATION PURPOSES by Interchange Way Ontario L4K 5W3 905 660 4655 905 660 4113 Witmer Industrial Estates Falls NY 14305 Free 888 660 4655 Toll Free 888 660 4113 page http www mircom com Email mail mircom com 5635 4

Related Files