PRE ACTION DELUGE AGENT RELEASING CONTROL UNIT SERIES to UL 864 9th edition configurable to operate with a Deluge Sprinkler a Pre action Sprinkler System and an Agent System Six Class B Style B Input Circuits Circuits One to Four can be configured as Non Alarm Non Latching Supervisory Latching or Agent Release Water Flow depending on Mode of Operation selected Circuits Five Six can be configured as Manual Input Abort Input or Abort Manual Release Input depending on the Mode of Operation Circuits can be converted to Class Style the ICAC 306 Converter Module Class Style Output Circuits which can configured for Silenceable Signal Non Silenceable Silenceable Strobe Non Silenceable or Releasing Circuit Circuits 3 4 Only Output Circuits can be converted to Class Style the OCAC 304 Converter Module Amp Power Supply smoke power 22.3 VDC 300ma max Supervised Power 22.3 VDC 500ma max Aux Power Unregulated 24 VDC 1.7 Amp max R e l a y c o n t a c t s f o r C o m m o n A l a r m N o n Auxiliary Alarm Disconnectable Supervisory can be converted to common if no Supervisory input and Common Trouble Cross Zone option Counting Zones option Output signals can be configured for Steady fixed or tone changes as input operation changes Release Timer 0 to 60 Seconds 5 second increments Manual Release Delay 0 to 30 Seconds 5 second Soak Timer 0 to 15 Minutes 21 Intervals Abort Release Timer Standard UL Type Delay IRL Delay NYC Type Delay Local Jurisdiction Delay Special Releasing Power Supply and Release Activation preventing false dumps Configurable to perform two hazard areas Simple panel programming through 14 Pre Configured of Operations NUMBER FR 320 is a dual releasing control unit that is field for use on Deluge Sprinkler Systems Pre action Systems and Agent Release Systems FR 320 is equipped with six Class Style input and four Class Style output circuits rated 1.7 maximum Total of 5 Amps Optional Class A converter are available for both input and output circuits In both internal and external relays are supported by FR 320 The relays can be configured for both single and hazard applications FR 320 is field configurable for three releasing type Deluge Pre Action Sprinklers and Agent Releasing mode of operation is easily configured by selecting one of pre configured modes of operation The simple configuration is done via the front panel using the CFG 300 tool thus eliminating the need for a laptop or programming FR 320 comes complete with a red FR 320 R door black durable CAT 30 lock and key and space to mount to 12 AH batteries TO BE USED FOR INSTALLATION PURPOSES INFORMATION IS FOR MARKETING PURPOSES ONLY AND INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY Modules Input Circuit Class Converter Module ICAC 306 converts six Class Style input circuits on FR 320 to Class Style circuits The ICAC 306 is with wire leads to connect to the FR 320 main board Output Circuit Class Converter Module OCAC 304 converts four Class Style output on the FR 320 to Class Style circuits The is equipped with wire leads to connect to the main board Relay Circuit Adder Module RM 306 provides six configurable relay circuits rated VDC 1 amp resistive The RM 306 can be configured single or dual hazard applications Smart Relay Module SRM 312 provides the same features as the RM 306 The SRM 312 provides twelve configurable relay rated 28 VDC 1 amp resistive The SRM 312 with a red enclosure and is mounted remotely from the on an RS 485 connection Annunciators Remote LED Annunciator RAM 216R provides16 points respectively of LED and features bi coloured LEDs which are for either Alarm red or Supervisory amber LED annunciators have indicators for A C On Common and Signal Silence and control switches for System Signal Silence Lamp Test and Buzzer Silence The is equipped with a keyswitch which allows for and disabling of the Common Control functions and available in a red finish and mount in a 4 gang electrical box Main Remote LED Annunciator RAM 1032TZDS Main Remote LED Annunciator common annunciator functions and 32 points of annunciation The RAM 1032TZDS has indicators for On Common Trouble and Signal Silence and controls System Reset Lamp Test Fire Drill Buzzer Silence and Silence The RAM 1032TZDS occupies the one display in the BB 1001D BB 1001DR BB 1001DB and enclosures Releasing Control Unit c w red door and black backbox minus built in trim ring 26 x 14.5 x 4.2 Information Control Unit Annunciators and Modules Modules Multiplex Annunciator with 16 Bi Colored LEDs Red Remote LED Annunciator c w 32 Bi Colored LEDs Relay Module Red enclosure enclosure for one RAM 1032TZDS module white door enclosure for one RAM 1032TZDS module red door enclosure for one RAM 1032TZDS module black door enclosure for one RAM 1032TZDS module stainless finish door Input Circuit Class Converter Module Output Circuit Class Converter Module Relay Circuit Adder Module Relay Circuit Adder Module Tool Required for programming End Of Line Module Red Plate Interchange Way Vaughan ON L4K 5W3 905 660 4655 Fax 905 660 4113 Witmer Industrial Estates Niagara Falls NY 14305 Free 888 660 4655 Fax Toll Free 888 660 4113 INFORMATION IS FOR MARKETING PURPOSES ONLY AND INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY complete and accurate technical information relating to performance installation testing certification refer to technical literature This document contains intellectual property of The information is subject to change by Mircom without notice Mircom does not or warrant correctness or completeness All rights reserved All other trademarks registered trademarks are properties of their respective owners 5664 4

Related Files