Mircom CAT-5666 BPS-802 Remote Power Supply (English)

File Preview
File Preview
Click below to download for free

File Data

Name mircom-cat-5666-bps-802-remote-power-supply-english-6098472153.pdf
Type PDF
Size 778.55 KB
Downloads

Text Preview

REMOTE POWER SUPPLY input 115VAC 60 Hz 1.45 amp 2 Class A or two 2 Class B FACP inputs selectable 24VDC or 12VDC voltage regulated limited outputs 2 NC dry contact trigger inputs or 12VDC rated 8 amp max total alarm amp max current per output 1 Amp auxiliary output with built in and reset capability 2 outputs may be paralleled for more power an indicating circuit supervised indicating circuit outputs to Four 4 Class B or Two 2 Class A or One 1 A and Two 2 Class BThermal and short circuit with auto reset charger for sealed lead acid or gel type switchover to stand by battery when AC Fails voltage drop when switching over to battery backup battery protection fail supervision form contact 1 amp Factory set for 1 minute with optional 18 delay setting eld selectable presence and low battery supervision form contact 1 amp 28VDC and output status LED indicators wire horn strobe Sync mode allows audible cation appliances horns to be silenced while noti cation appliances strobes continue to Code 3 Steady Mode Input to Output Mode maintains synchronization of cation appliances circuit sync protocols include Mircom Amseco System Sensor Faraday and Wheelock Time with 12 or 24VDC re panels and electronically regulated output loop supervision steered to input 1 or input 2 trouble input and output fault detection includes power supply red enclosure cam lock frame transformer and battery leads BPS 802 is an extremely cost effective 8 amp regulated remote power supply battery charger may be connected to any 12 or 24 volt Fire Alarm Panel FACP Primary applications include cation Appliance Circuit NAC such as strobes and expansion support to meet ADA requirements also provides auxiliary power to support system The unit delivers regulated and ltered or 12 volt power to Class B or Class A NAC loop a separate 1.0A auxiliary output with reset four 4 wire smoke detectors is available The 8 rated supply current can be divided between the 4 outputs for powering NAC devices Each output rated at 2.5 amp max and can be independently for Steady Temporal Code 3 or Strobe All outputs may be programmed for to Output Follower Mode output will follow input March Time Input March Time Output An individual of 4 amp is achieved by paralleling 2 outputs BPS 802 in non alarm condition independent loop for Class A and or Class B FACP NAC circuits provided In the event of a loop trouble the FACP will noti ed via the steered input input 1 or input 2 In there are common trouble output terminals C N O which are used to indicate general loop trouble A common trouble input is provided for NC normally closed devices to report trouble the FACP Two 2 FACP signaling outputs can be and directed to control supervision and power to any combination of the four 4 outputs unit also features Output trouble memory to identify trouble some sporatic problems reserves the right to make changes at any time without notice in prices colours materials components equipment speci cations and models and also to discontinue models TO BE USED FOR INSTALLATION PURPOSES 95E 13 NUMBER Supply Speci cations Input Current Resistor end of line Speci cations Batteries two 2 12VDC batteries in series Battery Battery Dimensions x 12 x 4.5 1.45 amp 60Hz 24VDC Maximum 2.5 amp per output of 8 amp in Alarm Condition 12VDC operation use a 12VDC 12AH battery 24VDC operation use two 2 12VDC 12AH or two 2 12VDC 7AH batteries connected in series 2200 ohm Time Output Total Amp Minutes Output Current Hours Hours Hours Hours Hours Hours Hours amp 15 Minutes amp 5 Minutes amp 5 Minutes amp 15 Minutes amp 5 Minutes amp 15 Minutes amp 15 Minutes amp amp Information Amp Remote Power Supply TO BE USED FOR INSTALLATION PURPOSES by Interchange Way Ontario L4K 5W3 905 660 4655 905 660 4113 Witmer Industrial Estates Falls NY 14305 Free 888 660 4655 Toll Free 888 660 4113 page http www mircom com Email mail mircom com 5666 2

Related Files