Mircom CAT-5667 BPS-1002 Remote Power Supply (English)

File Preview
File Preview
Click below to download for free

File Data

Name mircom-cat-5667-bps-1002-remote-power-supply-english-3807415269.pdf
Type PDF
Size 781.04 KB
Downloads

Text Preview

REMOTE POWER SUPPLY input 115VAC 60 Hz 4.4 amp 2 Class A or two 2 Class B FACP inputs selectable 24VDC or 12VDC voltage regulated limited outputs 2 NC dry contact trigger inputs 10 amp max total alarm current amp max current per output 1 Amp auxiliary output with built in and reset capability 2 outputs may be paralleled for more power an indicating circuit supervised indicating circuit outputs to Four 4 Class B or Two 2 Class A or One 1 A and Two 2 Class BThermal and short circuit with auto reset charger for sealed lead acid or gel type switchover to stand by battery when AC Fails voltage drop when switching over to battery backup battery protection fail supervision form contact 1 amp Factory set for 1 minute with optional 18 delay setting eld selectable presence and low battery supervision form contact 1 amp 28VDC and output status LED indicators wire horn strobe Sync mode allows audible cation appliances horns to be silenced while noti cation appliances strobes continue to Code 3 Steady Mode Input to Output Mode maintains synchronization of cation appliances circuit sync protocols include Mircom Amseco System Sensor Faraday and Wheelock Time with 12 or 24VDC re panels and electronically regulated output loop supervision steered to input 1 or input 2 trouble input and output fault detection includes power supply red enclosure cam lock frame transformer and battery leads BPS 1002 is an extremely cost effective 10 voltage regulated remote power supply battery It may be connected to any 12 or 24 volt Fire Control Panel FACP Primary applications Noti cation Appliance Circuit NAC such as and horns expansion support to meet ADA It also provides auxiliary power to support accessories The unit delivers regulated and ltered 24 volt power to Class B or Class A NAC loop a separate 1.0A auxiliary output with reset four 4 wire smoke detectors is available The 10 max alarm current can be divided between the 4 outputs for powering NAC devices Each output rated at 2.5 amp max and can be independently for Steady Temporal Code 3 or Strobe All outputs may be programmed for to Output Follower Mode output will follow input March Time Input March Time Output An individual of 4 amp is achieved by paralleling 2 outputs BPS 1002 non alarm condition provides loop supervision for Class A and or Class FACP NAC circuits In the event of a loop trouble the will be noti ed via the steered input input 1 or 2 In addition there are common trouble output N C C N O which are used to indicate loop system trouble A common trouble input provided for optional NC normally closed devices report trouble to the FACP Two 2 FACP signaling can be employed and directed to control and power delivery to any combination of four 4 outputs The unit also features Output memory indication to help identify trouble some problems reserves the right to make changes at any time without notice in prices colours materials components equipment speci cations and models and also to discontinue models TO BE USED FOR INSTALLATION PURPOSES NUMBER Supply Speci cations Input Current Resistor end of line Speci cations Batteries two 2 12VDC batteries in series Battery Battery Dimensions x 12 x 4.5 4.4 amp 60Hz Maximum 2.5 amp per output of 10 amp in Alarm Condition 12VDC operation use a 12VDC 12AH battery 24VDC operation use two 2 12VDC 12AH or two 2 12VDC 7AH batteries connected in series 2200 ohm Time Output Total Amp Minutes Output Current Hours Hours Hours Hours Hours amp 15 Minutes amp 5 Minutes amp 5 Minutes amp 15 Minutes amp 15 Minutes amp amp Information Amp Remote Power Supply TO BE USED FOR INSTALLATION PURPOSES by Interchange Way Ontario L4K 5W3 905 660 4655 905 660 4113 Witmer Industrial Estates Falls NY 14305 Free 888 660 4655 Toll Free 888 660 4113 page http www mircom com Email mail mircom com 5667 2

Related Files