INTELLIGENT FIRE CONTROL UNIT AGENT RELEASE CONTROL UNIT FX 3500 SERIES Features One onboard SLC DCL communication circuit supports up 318 addressable devices Expandable to three SLC DCL communication that supports up to 954 addressable Reliable and industry proven dedicated power supply Six dedicated hazard zone LED indicators Convenient USB Programming port Built in UDACT DACT for remote monitoring Enhanced tactile response for operator x 20 character Liquid Crystal Display LCD Easy to read numerical keypad Ampere Amp Power Supply to satisfy releasing load requirements Four Class A B Notification Appliance Circuits rated at 1.5Amp each SLC is capable of NFPA 72 Style 4 Style 6 or 7 wiring ULC DCL A DCL B Resettable auxiliary power supply Four easy to read status queues with selector and LEDs for Alarm Supervisory and Building Safety Formerly Monitor visual indications Supports up to seven remote annunciators Accessible multifunction RS 232 port for RS 485 Interface for remote LCD LED Serial Communication interface and other devices Optional City Tie Polarity Reversal module for station monitoring with two optional RAX 1048TZDS modules FX 3500 is a series of powerful Intelligent Fire Alarm Control Units which include Control Units RCUs These panels are UL 9 and ULC S527 2011 listed for fire control and service FX 3500 is recommended for both new and retrofit infrastructure suppression special applications Small in enclosure size yet powerful to deliver complex programming requirements FX 3500 is fully expandable FX 3500 provides up to three addressable Signal Circuits UL or ULC Communication DCLs and connects up to 954 addressable Capable of releasing up to six discrete hazard zones the FX 3500 offers exceptional for complex installations configuration options by onsite laptop or when by the Engineer of Record by remote PC via the FX 3500 can be operational with minimal up time versatility makes the FX 3500 Series the choice for dependable fire detection signaling protection in industrial commercial and institutional Typically these environments require agent suppression solutions easily managed by the Intelligent Addressable Release Control Unit reserves the right to make changes at any time without notice in prices colours materials components equipment specifications and models and also to discontinue models TO BE USED FOR INSTALLATION PURPOSES Dept 6165 NUMBER Features The FX 3500 supports both flush and surface applications x 14.5 x 4.2 cm x 36 cm x 11 cm Dimensions Modular display placement options Fits up to 2 18 Ampere Hour batteries Durable CAT 30 lock and key Removable enclosure door Easy access to all modules for serviceability and Operational Features alarm response within three seconds of in Advanced Protocol mode when using devices only Releasing capability for up to 6 Zones Supports Pre Action Agent Release and AP is a completely digital protocol AP is an Interrupt base protocol LED Control Applications Supports up to 3 SLC loops and 954 points Supports CLIP and AP System Sensor Built in strobe synchronization support for Potter Amseco System Sensor and Wheelock protocols Grouped inputs and outputs NACs can be configured as Silenceable or for both signals and strobes Group bypass with built in false alarm technology Zone Counting Built in Drift Compensation for AP protocol Positive Alarm Sequence Configurable Signal Silence Inhibit Auto Signal Two Stage Operation and One Man Test Relay contacts for Common Alarm Auxiliary Disconnectable Common Supervisory Common Trouble Two event history logs comprised of a 400 alarm log for alarm related events and a event general log for all other events Features Compatible with INX 10A Addressable NAC Expander Panel Supports Acclimate smoke detection sensors can be configured as Alarm Input Priority Alarm Verified Alarm Non Latching Supervisory Monitor Trouble Input Supervisory Features and Benefits Cross zoned or Counting Zone Smoke programming to enable release by counting active zone detection circuits or cross zoned detection circuits includes for single double triple and 2 different counting zones The FX 3500 Series RCUs are fully expandable meet the demanding requirements for critical facilities both inside the value asset areas and also in the office TO BE USED FOR INSTALLATION PURPOSES 5690 2 of 6 Adder Modules Annunciators Programmable LED Annunciator Module RAX 1048TZDS Programmable LED Annunciator provides FX 3500 with 48 Programmable Alarm Supervisory LEDs 48 Trouble LEDs which can be configured as Red Supervisory Amber Trouble Amber or Monitor The RAX 1048TZDS mounts in the FX 3500 enclosure Dual Loop Controller Module ALC 636 Dual Analog Loop Controller Module provides two Signaling Line Circuits SLC to the FX 3500 consisting 159 intelligent sensors and 159 intelligent modules per loop ALC 636 mounts in the FX 3500 enclosure Polarity Reversal City Tie Module h e P R 3 0 0 p r o v i d e s o u t p u t s f o r c i t y b o x a n d reversal applications As a city tie module the provides an interface between the control panel circuits and a master box As a polarity reversal module PR 300 provides an interface between the control panel and reverse polarity receiver Remote LCD Annunciator RAM 3500 LCD provides remote annunciation through a line by 20 character LCD display It is a direct mimic of the panel display so that the LCD LEDs and switches are an duplicate of the main display The RAM 3500 LCD provides switches for System Reset Signal Silence Fire Drill and four Status Queues with selector switches and for Alarm Supervisory Trouble and Monitor along with a keypad to access the menu functions The RAM 3500 mounts in separately orderable single unit enclosures or in enclosures that support up to two optional RAX 1048TZDS LED annunciators All remote enclosures are equipped a CAT 30 Lock and key Remote LCD Annunciator RAX LCD LITE LCD Annunciator The RAX LCD LITE display the main Fire Alarm Panel display at a remote It is equipped with a large 4 line x 20 character back lit LCD display uses a simple menu complete with a directional keypad and switches for Menu Cancel and Info There are five types of enclosure the BB 1001 BB 1002 BB 1003 BB 1008 and which can take 1,2,3,8,12 chassis respectively TO BE USED FOR INSTALLATION PURPOSES 5690 3 of 6 Series Fire Alarm Control Panel signal processor based design fully configurable from front panel with password protection ratings line voltage 120VAC 60Hz 240VAC 50Hz 10A slow blow fuse on secondary of transformer Battery loops Circuits supply 1 supply 2 supply relays supply rating 29VAC 10A maximum secondary of transformer 120VAC 60Hz 3.1Amp maximum primary of transformer 240VAC 50Hz 1.57Amp maximum primary of transformer Total load not to exceed 10A at 24VDC 24VDC Gel Cell Sealed lead acid 10AH to 42AH capability 10AH to 42AH current 3A maximum

Related Files