Mircom CAT-5810 QX-MINI (English)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | mircom-cat-5810-qx-mini-english-0451897623.pdf |
---|---|
Type | |
Size | 1.41 MB |
Downloads |
Text Preview
EMERGENCY COMMUNICATION SYSTEM Up to 60 watts per enclosure 2 X 30W amplifiers and up 360 watts per system 2 X 2.5A regulated 24V output for horns and strobes NAC System expandable to 12 X 2.5A Class A or Class B Speaker and NAC wiring Field selectable 25V or 70.7V audio output Comes with standard digital messages for fire evacuation weather and all clear Select from up to 14 digital messages at the panel Custom message upload using the software configurator Stores up to 12 minutes of audio messages Master microphone input with push to talk PTT Supports up to 6 remote microphones and or LOCs Use as a separate audio system or as part of a fire alarm Two inputs for activation by conventional fire alarm using relays Two strobe inputs for synchronization and activation Signalling Line Circuit SLC input for activation and with Mircom compatible Fire Alarm Control Battery backup up to 75AH charge capacity Dedicated Trouble AC Fail and Alarm relay outputs Audio system supports up to 6 panels in total one Master with 5 Booster Panels 12 expandable up to 36 Programmable Switches Auxiliary 24V supply up to 0.2A ULC UL CSFM Amplifier Module Audio amplifier Splitter 24 Zone Selector Modules Booster Panel Remote Microphone LOC QX mini is an emergency and fire alarm audio system to provide notification for small to medium The QX mini supplies 30W for audio output and for Notification Appliance Circuits NAC The optional 30 Amplifier Module increases audio output to 60W can be sent using stored digital message the master microphone or remote microphones QX mini comes with standard notifications and can store to messages for a total of 12 minutes of digital message Up to six remote microphones and or LOCs can connected to the QX mini QX mini operates either as a stand alone audio system or part of a fire alarm system Conventional fire alarm systems the with relays Mircom compatible Fire Alarm Control can control the QX mini using Signalling Line Circuit Booster Panels provide support for a distributed These Booster Panels act as true slaves to the master respect to Outputs All Inputs Microphones and User are disabled on Booster Panels and they cannot programmed through the configuration software Up to five Panels can be connected to a QX mini TO BE USED FOR INSTALLATION PURPOSES INFORMATION IS FOR MARKETING PURPOSES ONLY AND INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY NUMBER Amplifier with QAS 2X8 Audio Amplifier Splitter there are 2 amplifiers installed one of them can be configured as a backup If the main amplifier fails the backup amplifier over Amplifier with QAS 2X8 Audio Amplifier Splitter Amplifier with QAS 2X8 Audio Amplifier Splitter EOL EOL Class A or B B shown or QAS 2X8 or EOL if this output is not used Class A or B B shown or QAS 2X8 or EOL if this output is not used EOL EOL Class A or B B shown or Class A or B EOL if this B shown or is not used EOL if this is not used EOL EOL A A A A 1 A A 1 2 A A 2 A A 1 A A 1 A A 2 A A 2 1 B A A 1 2 B A A 2 B A A B A A 1 2 B A A 1 B A A 2 1 B A A B A A 1 to 8 Audio Outputs with 2 different audio messages per Panel QAS 2X8 Audio Amplifier Splitter connecting 2 amplifiers to the audio zone splitter in an application where each amplifier plays a different audio message example one amplifier can provide an alarm signal to a zone and the other amplifier can provide an alert signal to the other to 8 Audio Outputs with 2 different audio messages per Panel with QAS 2X8 Audio Amplifier Splitter This configuration provides 8 outputs The 8 outputs can select from 1 amplifier 2 or they can be off to 8 Audio Outputs with 2 different audio messages per Panel with QAS 2X8 Audio Amplifier Splitter EOL EOL A A A A 1 A A 1 2 A A 2 1 2 B A A 2 B A A 1 03 DAQ B A A B A A 03 DAQ EOL A A 1 A A 1 EOL A A 2 A A 2 1 2 B A A 1 B A A 2 03 DAQ B A A B A A 03 DAQ 1 2 1 2 1 2 1 2 1 2 1 2 TO BE USED FOR INSTALLATION PURPOSES INFORMATION IS FOR MARKETING PURPOSES ONLY AND INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY 5810 2 of 3 X 30W Circuits X 2.5A Circuits X 30W Circuits X 2.5A Circuits X 30W Circuits X 2.5A Circuits or Relays Alarm Panel Panel Panel Panel Sync Sync Microphone audio system with a FACP a QX MINI Master Panel two Booster Panels and two Remote Microphones x 14.5 x 4.2 Line Voltage 60Hz 240V 50Hz 3.1 Amps 1.57 Amp audio 60W max and 2 X 2.5A NAC 5A max Gel Cell Sealed Lead Acid Capability to 75AH charge capacity Consumption 215mA 220mA Power Fault Fault Active Select 4 Select 8 Call listed Fire Alarm Control Panels Active Active Ready Reset Test Silence Information Panel Microphone Main Display Main Board 1 x 30W Amplifier Deadfront Red Door Backbox Back Plate Panel Outer Red Door Main Board acting in slave mode 1 x 30W Amplifier Backbox Back Plate Transformer Microphone Backbox Red Door Microphone RMIC PCB Operating Console Main Display Microphone RMIC PCB Deadfront Backbox Red Door Watt Amplifier Module Zone Controller amplifier Splitter Interchange Way Ontario L4K 5W3 905 660 4655 905 660 4113 Witmer Industrial Estates Falls NY 14305 Free 888 660 4655 Toll Free 888 660 4113 INFORMATION IS FOR MARKETING PURPOSES AND NOT TO DESCRIBE THE TECHNICALLY complete and accurate installation testing and certification refer to technical This document contains intellectual property of Mircom information is subject to change by Mircom without notice does not represent or warrant correctness or completeness relating 5810 8