Mircom CAT-5910 FX-2000 Series Intelligent Fire Alarm Control Panel (English)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | mircom-cat-5910-fx-2000-series-intelligent-fire-alarm-control-panel-english-8362470915.pdf |
---|---|
Type | |
Size | 2.43 MB |
Downloads |
Text Preview
INTELLIGENT FIRE ALARM CONTROL PANEL SERIES to UL 864 9th edition system capacity Modular design Each Analog Loop is capable of supporting 99 Analog and 99 Addressable Modules which can be in Class A Style 6 or 7 or Class B Style 4 Base system supports 16 conventional hardwired with the provision to add more using the Hardwire Loop Controller Module or 12 Amp power supply Four Class A B Style Z Y Indicating Circuits rated at Amps each Configurable for Two Stage operation Three level password protection with field definition which enables the installer determine what functions are accessible for each level Panel Security to protect site configurations Manual Control Enable which allows password for all front panel function switches Correlatable Switch Inputs which allows for multi outputs Four Alarm Queues with selector switches and LEDs Alarm Supervisory Monitor and Trouble Auxiliary relay contacts for Common Alarm Common and Common Trouble RS 232 output for remote system printer or CRT Two Event History Logs comprised of a 1000 Alarm Log for alarm related events and a 2000 Event for all events Front Panel Auto Configure and or Computer laptop 4 by 20 character Back lit LCD Display with user menu Common Control switches and or indicating LEDs for Reset Signal Silence Fire Drill Acknowledge Alarm Lamp Test A C On Pre Alarm and Fault Built in One Man Walk Test operation Configurable for Coded Operation Supports an RS 485 interface to the QX 5000 Voice System Panel selection for Canadian ULC or U S A UL for smoke sensors sensitivity via laptop Capability to adjust Intelligent Smoke Detector level of I Con E15095 II Con E15096 I Add E15097 II Add E15098 FX 2000 Series Microprocessor Based Fire Alarm Control Panel is designed provide maximum flexibility of analog system while also providing easy installation operation at a cost effective price FX 2000 base panel consists of one intelligent loop controller capable of supporting 99 Analog and 99 Addressable Modules which can be in Class A Style 6 or 7 or Class B Style 4 The can be expanded by adding additional Analog Controller Modules In addition the base panel 16 conventional hardwire adder modules as the DM 1008A Initiating Circuit Module SGM Indicating Circuit Module and the RM 1008A Circuit Module Additional conventional hardwire modules can be added with the ALC H16 Adder Loop Controller Module which allows the to support an additional 16 conventional adder The base panel also consists of 4 Class A B Z Y Indicating Circuits rated at 1.7 Amps each either a 6 or 12 Amp Power Supply with a large 4 x 20 Back lit Alphanumeric display the FX 2000 utilizes a simple Menu complete with a directional keypad common switches and LEDs Alarm Queue switches and and two configurable input switches reserves the right to make changes at any time without notice in prices colours materials components equipment specifications and models and also to discontinue models TO BE USED FOR INSTALLATION PURPOSES NUMBER FX 2000 is field programmable via the front auto configuration or a laptop computer addition it allows for a three level password that can be field defined via a laptop This unique feature allows the installer determine what functions are accessible for each level system is also equipped with two Event History one for Alarm and the other for full panel events The Alarm History Log 1000 contains all alarm related functions while the Log 2000 events provides a full sequence of all operations as well as alarms and troubles Event History Logs can be used during the One Walk Test operation This allows the event to be downloaded to a laptop or printer for a record FX 2000 is a very flexible system which both internal and external annunciation The internal annunciation modules consist the RAX 1048TZDS Programmable Zone LED the IPS 2424DS Programmable Input Module the FDX 008 Fan Damper Module the AGD 048 Adder Graphic Driver Module Correlations input circuits addressable or hardwired can be for non verified alarm verified alarm latching non latching supervisory monitor only or remote switch inputs All of the input types listed above with the exception remote switch can be programmed to operate signal and strobe circuits for hardwired or devices Please refer to the chart below correlations The input circuits configured as non will cause the output circuits configured to to follow the state of the input device This allows for the connection of multiple panels for signal operation of these modules mount within the panel and driven from the main LCD display The external modules include the RAM 1032TZDS RAX 1048TZDS LED Remote Annunciators MGD 32 Master Graphic Driver Module and RAX LCD Remote LCD Shared Display The Remote LCD Shared Display provides the features as the main display on the FX 2000 addition the RAX LCD also acts as a driver module allows for the RAX 1048TZDS IPS 2424DS and AGD 048 to be connected to it The is required as a driver module any time of the above mentioned external annunciator are programmed differently from those the main panel or are mounted remote from the panel addition to these adder modules the FX 2000 also the UDACT 300A Digital Communicator and the PR 300 Polarity Reversal City Tie The FX 2000 also supports an RS 485 to the QX 5000 Emergency Zoned Audio Remote Switch input which must be momentary any input type device addressable or to be configured as a common control such as fire drill system reset signal etc The remote switches operate in a mode like the control switches on the FX main panel For functions such as fire drill the switch functions in a toggle mode with one for and one press for The remote is supervised for in on positions where switch input is activated stuck for more than 30 If this occurs a trouble is generated and when the input goes away Switches or Conventional Types Alarm Supervisory Supervisory Only Switch Input TO BE USED FOR INSTALLATION PURPOSES 5910 2 of 10 Standard Series Mid Size Main Control Unit FX 2017 12ADS Mid Size Main Control Unit comes complete with intelligent Signaling Line Circuit SLC Four Style Z Y Class A B NAC Circuits Amps each a 4 line by 20 character back lit LCD display and a 12 Amp Supply which charges 17 55 AH batteries The FX 2017 12ADS space for up to 17 adder modules and 3 internal annunciator adder The FX 2017 12ADS mounts in the BBX 1072ADS enclosure Compact Main Control Units FX 2003 6DS and FX 2003 12DS Compact Main Control Units come with one Intelligent Signaling Line Circuit Four Style Z Y Class Notification Appliance Circuits rated at 1.7 Amps each and a 4 line by 20 back lit LCD display The FX 2003 6DS is equipped with a 6 Amp Supply which charges 10 24 AH batteries while the FX 2003 12DS a 12 Amp Power Supply which charges 17 55 AH batteries The provides space for 3 adder modules and internal annunciator adder modules The FX 2003 6DS FX 2003 12DS in a UB 1024DS backbox Large Size Main Control Unit FX 2009 12DS Large Size Main Control Unit comes complete with Analog Loop Controller 99 Analog Sensors and 99 Addressable 4 Class A B Style