Mircom CAT-5926 BEAM200 Series Intelligent Beam Smoke Detectors (English)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | mircom-cat-5926-beam200-series-intelligent-beam-smoke-detectors-english-2873540691.pdf |
---|---|
Type | |
Size | 1.06 MB |
Downloads |
Text Preview
INTELLIGENT BEAM SMOKE DETECTORS to 328 foot protection range Single ended reflective design Easiest alignment in the industry with digital display Optional integral NFPA 72 sensitivity test feature Removable plug in terminal blocks Built in automatic gain control compensates for signal field selectable sensitivity levels from dust build up Remote test station available Paintable cover Optional heater kits available BEAM200 device has four standard sensitivity selections with two Acclimate settings When either of the two settings are selected the detector automatically its sensitivity using advanced software algorithms to the optimum sensitivity for the specific environment BEAM200S model is equipped with an added feature an sensitivity test feature that uses a test filter attached a Servo motor inside the detector optics Using the remote station RTS151 the motor is activated and moves the in the pathway of the light beam thereby testing detector This integral sensitivity test feature allows the user quickly and easily meet the annual maintenance and test of NFPA 72 BEAM200 and BEAM200S single ended reflected beam detectors are uniquely suited for protecting open with high ceilings where other methods of smoke are difficult to install and maintain BEAM200 and BEAM200S intelligent reflected beam detectors are designed to be used with UL Listed control panels only Since all of the wiring is to one side the installation of the single ended design is much easier than dual ended projected detectors Alignment is accomplished quickly via an sight and a 2 digit signal strength meter incorporated the product Listed for operation from to 131 the detector can be used in open area applications to early warning in environments where temperature exceed the capability of other types of smoke BEAM200 smoke detector includes one wired transmitter unit and one reflector When smoke enters the area the unit and the reflector it causes a reduction in the The alarm is activated when the smoke level reaches predetermined threshold TO BE USED FOR INSTALLATION PURPOSES INFORMATION IS FOR MARKETING PURPOSES ONLY AND INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY NUMBER and BEAM200S Specifications Specifications Range Angle Levels Condition Aid Indicator Indicator Indicator Detector ft to 328 ft 5 m to 100 m Degrees horizontal vertical optics move independent of the unit 1 25 2 30 3 40 4 50 Level 1 30 to 50 Level 2 40 to 50 or more obscuration blockage alignment mode initial alignment limit reached gunsight signal strength indication digit display red LED and remote alarm yellow LED and remote trouble flashing green LED Sensitivity Test Filter BEAM200S only requires additional external power supply filter Incremental scale on reflector test switch reset switch test and reset switch Compatible with RTS151 and RTS151KEY test station smooth ceilings 30 to 60 feet between projected beams and not more than one half that spacing a projected beam and a sidewall Other spacing may be used depending on ceiling height characteristics and response requirements See NFPA 72 and CAN ULC S524 to 131 to 55 to 93 RH Noncondensing to 32 VDC mA Max Specifications Specifications Standby 24VDC Current Testing Current Current Mode 24VDC mA Max mA Max mA Max mA Max in H 7.5 in W 3.3 in D mm H 191 mm W 84 mm D in 9.1 in 200 mm 230 mm in 18.1 in 400 mm 460 mm Specifications to 230 230 Specifications BEAMHK Specifications BEAMHKR to 32 V mA at 32 V W at 24 V 3 W at 32 V to 32 V mA Max at 32 V per reflector W at 24 V 15 W at 32 V reflector TO BE USED FOR INSTALLATION PURPOSES INFORMATION IS FOR MARKETING PURPOSES ONLY AND INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY 5926 2 of 3 Parts Test Feature BEAM200S only GUNSIGHT MOTOR FILTER SIGNAL METER OPTICS KNOB OPTICS KNOB Only used for BEAM200S See electrical ratings PANEL OR DEVICE LINE VDC MAX PAIR IS NEXT Information Description beam smoke detector with 8 reflector beam smoke detector with 8 reflector and integral sensitivity test Add suffix for ULC model range accessory kit Includes 3 additional reflectors Required for applications in excess of 230 ft kit Provides ceiling or wall mount capability with increased angular adjustment for either the or the reflector When installed with the transmitter receiver unit BEAMSMK must be used as well mount kit for use with BEAMMMK duty multi mount kit for installations prone to vibration or where there is difficulty in maintaining the angle When installed with the transmitter receiver unit 6500 SMK must be used as well mount kit for use with the 6500 MMK kit for transmitter receiver unit See electrical requirements above kit for reflector See electrical requirements above test station used to initiate the NFPA sensitivity test function test station with key lock Interchange Way Ontario L4K 5W3 905 660 4655 905 660 4113 Witmer Industrial Estates Falls NY 14305 Free 888 660 4655 Toll Free 888 660 4113 INFORMATION IS FOR MARKETING PURPOSES AND NOT TO DESCRIBE THE TECHNICALLY complete and accurate installation testing and certification refer to technical This document contains intellectual property of Mircom information is subject to change by Mircom without notice does not represent or warrant correctness or completeness relating 5926 3