Mircom CAT-5938 FX-2003-6DS-16LED (English)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | mircom-cat-5938-fx-2003-6ds-16led-english-5201348769.pdf |
---|---|
Type | |
Size | 1.89 MB |
Downloads |
Text Preview
INTELLIGENT FIRE ALARM CONTROL PANEL FX 2003 6DS 16LED expandable to five Intelligent Signaling Line Circuits SLC SLC Loop is capable of supporting 99 Analog Sensors and Addressable Modules which can be wired in Class A Style 6 or or Class B Style 4 Class A B Style Z Y Notification Appliance Circuits rated at Amps each 4 by 20 character Back lit LCD Display with user friendly menu 16 bi colored LEDs for annunciation Amp power supply for two programmable modules and 3 adder modules for Two Stage operation level password protection with field programmable definition enables the installer to determine what functions are for each password level Security to protect site configurations Manual Control Enable which allows password protection for front panel function switches Switch Inputs which allows for multi functional Alarm Queues with selector switches and LEDs for Alarm Monitor and Trouble relay contacts for Common Alarm Common Supervisory Common Trouble output for remote system printer or CRT Event History Logs comprised of a 1000 Alarm History Log for related events and a 2000 Event Log for all events Panel Auto Configure and or Computer laptop Programmable Control switches and or indicating LEDs for System Signal Silence Fire Drill Acknowledge General Alarm Test A C On Pre Alarm and Ground Fault One Man Walk Test operation for Coded Operation selection for UL or ULC requirements for smoke sensors via computer laptop to adjust Intelligent Smoke Detector sensitivity level in a universal enclosure ordered separately FX 2003 6DS 16LED Intelligent Analog Fire Alarm Panel is designed to provide maximum flexibility of system requirements while also providing easy and operation at a cost effective price FX 2003 6DS 16LED base panel consists of one intelligent line circuit SLC capable of supporting 99 intelligent and 99 intelligent modules In addition the base panel Four Class A B Style Z Y Notification Appliance Circuits at 1.7 Amps each a 4 x 20 back lit alphanumeric LCD display 16 bi colored LEDs and a 6 Amp power supply FX 2003 6DS 16LED with 16 bicolored LEDs has provision mount two programmable modules such as a RAX 1048TZDS annunciator IPS 2424DS input switch module or an FDX 008 damper control module In addition the FX 2003 6DS 16LED up to 3 adder modules such as the ALC 396S SLC loop module or SGM 1004A indicating circuit module enclosure which is ordered separately consists of a black backbox with a beige DOX 1024DS or red DOX 1024DSR A Fire Retardant Lexan window in the hinged door allows for of the display and controls The enclosure comes with a CAT 30 lock and key and space is provided for up to 18 AH Cell batteries reserves the right to make changes at any time without notice in prices colours materials components equipment specifications and models and also to discontinue models TO BE USED FOR INSTALLATION PURPOSES NUMBER Standard Series Fire Alarm Control Panel Expanded Main Control Unit FX 2003 6DS 16LED Main Control Unit comes complete with one signaling line circuit 99 Analog Sensors and 99 Address Modules 4 Class A B Style Z Y Notification Appliance Circuits Amps each a 4 line by 20 character back lit LCD display with additional 16 LED for annunciation and a 6 Amp Power Supply charges 10 24 AH batteries The FX 2003 6DS 16LED has for two programmable modules and provides space for up 3 adder modules The FX 2003 6DS 16LED comes pre mounted a chassis that fits into the separately ordered UB 1024DS Backbox enclosure Loop Controller Modules Enclosure UB 1024DS enclosure supports one FX 2003 6DS 16LED and up 18 AH Batteries The enclosure features the universal CAT 30 lock a removable door for easy installation and servicing The enclosure available in a white DOX 1024DS or red DOX 1024DSR exterior The FA XT TRB Semi Flush Trim Ring is required for semi flush Dimensions 26 x 14.5 x 4.2 cm x 36 cm x 11 cm Single Analog Loop Controller Module ALC 198S Single Analog Loop Controller Module provides additional analog loop to the FX 2000 consisting of 99 Analog and 99 Addressable Modules The ALC 198S occupies module slot in the FX 2003 6DS 16LED Dual Analog Loop Controller Module ALC 396S Dual Analog Loop Controller Module provides two analog loops to the FX 2000 consisting of 99 Analog and 99 Addressable Modules per loop The ALC 396S one module slot in the FX 2003 6DS 16LED Hardwire Loop Controller Module ALC H16 Hardwire Loop Controller Module allows the FX 2000 support an additional sixteen 16 conventional hardwire adder The hardwire modules consist of the DM 1008 Eight Initiating Module SGM 1004 Four Indicating Circuit Module and the Eight Relay Circuit Module The ALC H16 occupies one slot in the FX 2003 6DS 16LED Standard Series System Maximums Input Circuits Output Circuits Intelligent Addressable Loops Remote LCD Annunciators Main LED Annunciators Manual Control Switches TO BE USED FOR INSTALLATION PURPOSES 5938 2 of 4 Hardwire Modules Modules Eight Initiating Circuit Module DM 1008A provides 8 Class B Style B or 4 Class A Style D Circuits configurable for Alarm Supervisory or Trouble The DM 1008A occupies one module slot in the FX 2003 Programmable LED Annunciator Module RAX 1048TZDS Programmable LED Annunciator Module provides programmable bi colored LEDs The RAX 1048TZDS connects the main panel or a RAX LCD or RAM 1032TZDS when mounted The RAX 1048TZDS occupies one display position in the BBX 1024XT BB 1000 or BB 5000 Series enclosures Four Indicating Circuit Module SGM 1004A provides 4 Class A B Style Z Y Notification Circuits configurable as Silenceable or Non Silenceable NAC circuit is rated at 1.7 Amps The SGM 1004A occupies module slot in the FX 2003 6DS 16LED Eight Relay Circuit Module RM 1008A provides the FX 2003 6DS 16LED with eight configurable relays per module Each relay provides Form C contact rated at 28 VDC 1 Amp resistive load well as a Green LED to indicate that the relay is active The occupies one module slot in the FX 2003 6DS 16LED Auxiliary Modules Digital Alarm Communicator Module UDACT 300A Digital Alarm Communicator Module allows the to transmit addressable point information to a central The UDACT 300A occupies one module slot in the FX 2003 Polarity Reversal City Tie Module PR 300 Polarity Reversal City Tie Module provides the system a supervised City Tie and Polarity Reversal connection The occupies one module slot in the FX 2003 6DS 16LED Fan Damper Control Module FDX 008 Fan Damper Control Module provides individually circuits which can be used for fan or damper control The connects to the main panel or the RAX LCD and occupies display position in the UB 1024DS BBX 1024XT BB 1000 or Series enclosures Programmable Input Switches Module IPS 2424DS provides 24 programmable switches that can be for ancillary functions such as zone bypass or added control functions The IPS 2424DS connects to main panel the RAX LCD when mounted remotely The IPS 2424DS occupies display position in the UB 1024DS BBX 1024XT BB 1000 or Series enclosures Electrical Specifications 60Hz 240V 50Hz Amps 1 Amps primary Amps Max secondary unfiltered Amps max Gel Cell Lead Acid AH batteries Capability Consumption Supply ratings Circuits Line Voltage mA mA TO BE USED FOR INSTALLATION PURPOSES 5938 3 of 4 Annunciators Remote LCD Annunciator RAX LCD Remote LCD Annunciator provides the same functions as main display on the fire alarm control panel The RAX LCD occupies display position in the BB 1000 or BB 5000 Series enclosures