Mircom CAT-5941 FleX-Net FX-2003 12N Network Fire Alarm Control Panel (English)

File Preview
File Preview
Click below to download for free

Text Preview

NETWORK FIRE ALARM CONTROL PANEL SLC loop expandable up to 9 Alarm Control Each SLC Loop is capable of supporting 159 Analog Sensors 159 Addressable Modules which can be wired in Style or 7 Class A or Style 4 Class B Style Z Y Class A B Notification Appliance Circuits at 1.7 Amps each System has the ability to mix CLIP and AP devices on the loop easy to use and readable 4 by 20 character Back lit Display English French Arabic and Hebrew language support by RAXN LCDG Annunciator in place of main Correlatable Switch Inputs which allow for multi functional Status Queues for Alarm Supervisory Trouble and Auxiliary relay contacts for Common Alarm Supervisory Group bypass with built in false alarm prevention Trouble RS 232 output for remote system printer or CRT Event History Logs one for Alarm related events and for all events Supports 3 configuration files with swap support Conventional Hardwire Adder Module expandability Built in Walk Test operation Canadian Two Stage operation Provision for two programmable modules Configurable for Coded Operation Smoke Detector sensitivity levels graphical monitoring and control using Mircom Open Navigator BACnet support Advanced Boolean logic functions Built in Ethernet port Remote diagnostics via a built in web server Audio Voice Evacuation with 520Hz capability UL listed for Smoke Control HVAC Fan and Damper Control Features Up to 63 nodes Peer to peer network communications Style 4 Class B or Style 6 or 7 Class A wiring Proprietary Arcnet Network Communications protocol Supports copper and or fiber optic network cable Dept 6064 NUMBER FleX Net Series is a powerful intelligent networkable alarm solution designed with many levels of flexibility to virtually any application of detection control notification emergency communications Features such as fire alarm audio voice evacuation BACnet Boolean networking and graphical work stations allow this modular to accommodate the simplest systems up to the most solutions the addition of the Advance Protocol AP Fire CO and 520 Hz support on both the addressable loop through the audio voice evacuation Mircom FleX Net is to take you even farther into the future with expanded for peer to peer network communications the allows for a maximum of 63 nodes while reliability flexibility and expandability base panel consists of one intelligent signaling line circuit capable of supporting 159 analog Sensors and 159 modules In addition the base panel includes Style Z Y Class A B Notification Appliance Circuits and easy to read and use large 4 x 20 back lit alphanumeric display network configuration allows the FX 2003 12NDS control to be connected to a Mircom network to provide additional circuits visual zones programmable notification appliance and relays The network interface module allows panels to communicate on a peer to peer network via a Arcnet Network Communications protocol TO BE USED FOR INSTALLATION PURPOSES INFORMATION IS FOR MARKETING PURPOSES ONLY AND INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY FX 2003 12NDS Network Series Fire Alarm Control Panels Compact Network Main Control Unit FX 2003 12NDS Compact Network Main Control Unit with one Intelligent Signaling Line Circuit Style 6 or 7 Four Style Z Y Class A B Notification Appliance rated at 1.7 Amps each a 4 line by 20 character LCD display and a 12 Amp Power Supply The provides space for the FNC 2000 Network Module two internal adder modules and two modules Loop Controller Modules Isolated Quad Loop Controller Module ALCN 792MISO Isolated Quad Loop Controller Module two Signaling Line Circuits SLC to the FleX system consisting of 159 Analog Sensors and 159 Modules per loop The ALCN 792MISO can be with the use of the ALCN 792D Daughter Board The ALCN 792MISO occupies one module slot Daughter board for Isolated Quad Loop Module ALCN 792D Daughter Board provides an additional two loops when connected to the ALCN 792MISO Isolated Loop Controller Module The daughter board mounts on of the ALCN 792MISO Universal Backbox UB 1024DS Universal backbox houses the and provides space to mount up to 17 AH A DOX 1024DS R door is ordered separately minus built in trim ring 26 x 14.5 x 4.2 Door DOX 1024DS mounts on the UB 1024DS backbox door features the universal CAT 30 lock and available in a white DOX 1024DS or red exterior Network Controller Modules Fire Network Controller Module FNC 2000 provides network capability to the panels One Fire Network Controller Module required per network node panel In addition the FNC 2000 an interface for adding an optional FOM 2000 SP Optic Network Adder Module The FNC 2000 mounts in FX 2003 12NDS Fiber Optic Network Adder Module FOM 2000 SP Fiber Optic Network Adder Module allows the use of fiber optic cabling on the FleX Net Series panels seamlessly connects to the interface on the FNC 2000 Fire Network Controller Module Specifications Input Power Supply Ratings NAC Circuits Type Charging 60Hz 240V 50Hz Amps 2 Amp primary Amps max secondary unfiltered 10 Amps max Voltage Drop Permitted A 3.3V and Class B 3.7V Gel Cell Sealed Lead Acid AH batteries TO BE USED FOR INSTALLATION PURPOSES INFORMATION IS FOR MARKETING PURPOSES ONLY AND INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY 5941 2 of 7 Hardwire Modules Auxiliary Modules Eight Initiating Circuit Module DM 1008A provides 8 Style B Class B or 4 Style D Class Initiating Circuits configurable for Alarm Supervisory or zones The DM 1008A occupies one module slot in FX 2003 12NDS Digital Alarm Communicator Module UDACT 300A Digital Alarm Communicator Module allows FX 2003 12NDS to transmit addressable point information a central station The UDACT 300A occupies one module in the FX 2003 12NDS Four Notification Appliance Circuit Module SGM 1004A provides 4 Style Z Y Class A B Notification Circuits configurable as Silenceable or Non Each NAC circuit is rated at 1.7 Amps The occupies one module slot in the FX 2003 12NDS Polarity Reversal City Tie Module PR 300 Polarity Reversal City Tie Module provides the with a supervised City Tie 24 VDC 200 mA max and Reversal connection 24 VDC open circuit 8 mA shorted The PR 300 occupies one module slot in the Modules Eight Relay Circuit Module RM 1008A provides the FX 2003 12NDS with eight configurable relays per module Each relay provides Form C contact rated at 28 VDC 1 Amp resistive load well as a Green LED to indicate that the relay is active The occupies one module slot in the FX 2003 12NDS Software Fan Damper Control Module FDX 008W Fan Damper Control Module provides programmed circuits which can be used for fan or control The FDX 008W connects to the main panel the RAXN LCD and occupies one display position in the BB 1000 or BB 5000 Series enclosures Graphic Navigator OpenGN Graphic Navigator OpenGN is a centralized fire management system that provides building or campus As a powerful integration tool OpenGN allows to monitor remote sites from multiple workstations smart phones located anywhere in the world OpenGN monitored buildings and campuses in both 2D and representations and is highly customizable Programmable Input Switches IPS 2424DS IPS 4848DS provides 24 48 programmable that can be configured f

Related Files