Mircom CAT-5946 FleX-Net™ FX-2003-12NXTDS - English

File Preview
File Preview
Click below to download for free

File Data

Name mircom-cat-5946-flex-net-fx-2003-12nxtds-english-9567312408.pdf
Type PDF
Size 1.32 MB
Downloads

Text Preview

NETWORK FIRE ALARM CONTROL UNIT Alarm Control 1 SLC loop expandable up to 21 Each SLC Loop is capable of supporting 159 Analog Sensors 159 Addressable Modules which can be wired in Style or 7 Class A or Style 4 Class B Four Style Z Y Class A B Notification Appliance Circuits at 1.7 Amps each System has the ability to mix CLIP and AP devices on the loop Display Large easy to use and readable 4 by 20 character Back lit English French Arabic and Hebrew language support by RAXN LCDG Annunciator in place of main Correlatable Switch Inputs which allow for multi functional Four Status Queues for Alarm Supervisory Trouble and Auxiliary relay contacts for Common Alarm Supervisory Trouble Group bypass with built in false alarm prevention technology RS 232 output for remote system printer or CRT Two event History Logs one for Alarm related events and for all events Supports 3 configuration files with swap support Conventional Hardwire Adder Module expandability Built in Walk Test operation Canadian Two Stage operation Provision for two programmable modules Configurable for Coded Operation Intelligent Smoke Detector sensitivity levels 3D graphical monitoring and control using Mircom Open Navigator BACnet support Advanced Boolean logic functions Built in Ethernet port Remote diagnostics via a built in web server Audio Voice Evacuation with 520Hz capability UL listed for Smoke Control HVAC Fan and Damper Control Features Up to 63 nodes Peer to peer network communications Style 4 Class B or Style 6 or 7 Class A wiring configuration Proprietary Arcnet Network Communications protocol Supports copper and or fiber optic network cable Dept 6064 NUMBER in a BBX 1024XTR enclosure two optional RAX 1048TZDS modules FleX Net Series is a powerful intelligent networkable alarm solution designed with many levels of flexibility to virtually any application of detection control notification emergency communications Features such as fire alarm audio voice evacuation BACnet Boolean networking and graphical work stations allow this modular to accommodate the simplest systems up to the most solutions the addition of the Advance Protocol AP Fire CO and 520 Hz support on both the addressable loop through the audio voice evacuation Mircom FleX Net is to take you even farther into the future with expanded for peer to peer network communications the allows for a maximum of 63 nodes while reliability flexibility and expandability base panel consists of one intelligent signaling line circuit capable of supporting 159 analog Sensors and 159 modules In addition the base panel includes Style Z Y Class A B Notification Appliance Circuits and easy to read and use large 4 x 20 back lit alphanumeric display network configuration allows the FX 2003 12NXTDS panel to be connected to a Mircom network to provide input circuits visual zones programmable notification circuits and relays The network interface module the panels to communicate on a peer to peer network a Proprietary Arcnet Network Communications protocol TO BE USED FOR INSTALLATION PURPOSES INFORMATION IS FOR MARKETING PURPOSES ONLY AND INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY FX 2003 12NXTDS Network Series Fire Alarm Control Units Network Main Control Unit FX 2003 12NXTDS Network Main Control Unit comes with one intelligent signaling line circuit Four Z Y Class A B Notification Appliance Circuits rated 1.7 Amps each a 4 line by 20 character back lit LCD and a 12 Amp Power Supply which charges 17 65 batteries The FX 2003 12NXTDS provides space for FNC 2000 Network Controller Module up to 8 adder and two programmable modules The FX 2003 mounts in the BBX 1024XT R enclosure Loop Controller Modules Isolated Quad Loop Controller Module ALCN 792MISO Isolated Quad Loop Controller Module two Signaling Line Circuits SLC to the FleX system consisting of 159 Analog Sensors and 159 Modules per loop The ALCN 792MISO can be with the use of the ALCN 792D Daughter Board The ALCN 792MISO occupies one module slot Daughter board for Isolated Quad Loop Module ALCN 792D Daughter Board provides an additional two loops when connected to the ALCN 792MISO Isolated Loop Controller Module The daughter board mounts top of the ALCN 792MISO Enclosure BBX 1024XT enclosure supports one FX 2003 12NXTDS up to 18 AH Batteries The enclosure features the universal lock and a removable door for easy installation and The enclosure is available in a white BBX 1024XT red exterior BBX 1024XTR The FA XT TRB Semi Flush Ring is required for semi flush mounting Dimensions 35 x 14 x 5 Network Controller Modules Fire Network Controller Module FNC 2000 provides network capability to the One Fire Network Controller Module is per network node In addition the FNC 2000 provides interface for adding an optional FOM 2000 SP Fiber Network Adder Module The FNC 2000 mounts in the Fiber Optic Network Adder Module FOM 2000 SP Fiber Optic Network Adder Module for the use of fiber optic cabling on the FleX Net It seamlessly connects to the interface on the Fire Alarm Network Controller Module Specifications Input Power Supply Ratings NAC Circuits Type Charging 60Hz 240V 50Hz Amps 2 Amp primary Amps max secondary unfiltered 10 Amps max Voltage Drop Permitted A 3.3V and Class B 3.7V Gel Cell Sealed Lead Acid AH batteries TO BE USED FOR INSTALLATION PURPOSES INFORMATION IS FOR MARKETING PURPOSES ONLY AND INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY 5946 2 of 7 Hardwire Modules Auxiliary Modules Eight Initiating Circuit Module DM 1008A provides 8 Style B Class B or 4 Style D Class Initiating Circuits configurable for Alarm Supervisory or zones The DM 1008A occupies one module slot in FX 2003 12NXTDS Digital Alarm Communicator Module UDACT 300A Digital Alarm Communicator Module the FX 2003 12NXTDS to transmit addressable point to a central station The UDACT 300A occupies module slot in the FX 2003 12NXTDS Four Notification Appliance Circuit Module SGM 1004A provides 4 Style Z Y Class A B Notification Circuits configurable as Silenceable or Non Each NAC circuit is rated at 1.7 Amps The SGM occupies one module slot in the FX 2003 12NXTDS Polarity Reversal City Tie Module PR 300 Polarity Reversal City Tie Module provides the with a supervised City Tie 24 VDC 200 mA max and Reversal connection 24 VDC open circuit 8 mA shorted The PR 300 occupies one module slot in the Modules Eight Relay Circuit Module RM 1008A provides the FX 2003 12NXTDS with eight configurable relays per module Each relay provides Form C contact rated at 28 VDC 1 Amp resistive load well as a Green LED to indicate that the relay is active The occupies one module slot in the FX 2003 12NXTDS Software Fan Damper Control Module FDX 008W Fan Damper Control Module provides programmed circuits which can be used for fan damper control The FDX 008W connects to the main unit the RAXN LCD and occupies one display position in the BB 1000 or BB 5000 Series enclosures Graphic Navigator OpenGN Graphic Navigator OpenGN is a centralized fire management system that provides building or campus As a powerful integration tool OpenGN allows to monitor remote sites from multiple workstations smart phones located anywhere in the world OpenGN monitored buildings and campuses in both 2D and representations and is highly

Related Files