Mircom CAT-5948 FleX-Net Isolated Quad Loop Adder Module (English)

File Preview
File Preview
Click below to download for free

Text Preview

Isolated Quad Loop Adder Module Dedicated Central Processor Unit CPU per Expands system capacity to 636 addressable on 2 loops 159 159 per loop With the addition of the ALCN 792D this expands an additional 2 loops bringing module to 1272 addressable devices ALCN 792MISO Isolated Quad Loop Adder Module two addressable loops plus an additional two as part of the daughter board ALCN 792D which mounted over the ALCN 792MISO The quad loop module provides Signaling Line Circuits SLC to Flex Net Addressable Fire Alarm system consisting 159 Sensors and 159 Addressable Modules per loop ALCN 792MISO Loop Controller Module has a Central Processor Unit CPU and will support fully loaded SLC lines which will provide up to 318 devices per SLC line for a total of up to addressable devices per ALCN 792MISO Quad Controller module ALCN 792MISO occupies one module space on FleX Net FX 2000N Series control panel chassis ALCN 792D daughter board provides two additional lines for up to 318 addressable devices per SLC for a total of up to 1,272 addressable devices per ALCN 792MISO with ALCN 792D reserves the right to make changes at any time without notice in prices colours materials components equipment specifications and models and also to discontinue models TO BE USED FOR INSTALLATION PURPOSES NUMBER Diagram mounting holes mount to board with screws spacers provided S 3 4 Normally set to can be set to 2 3 prevent noise from System Sensor bases on 3 Main Board Connector P6 Normally set to can be set to 2 3 prevent noise from System Sensor bases on 4 ribbon cable this board to the board P6 leave open leave closed flashing LED for on processor 1 2 USED S OUT 1 LED 2 LED PORT use only flashing heartbeat Board shaded holes are Daughter board 2 holes and 2 holes are for the ALCN Quad Loop module SWITCH SWITCHES ARE FOR THIS ADDRESS SW1 1 THE LEAST SIGNIFICANT BINARY ACTIVE IS ON CABLE OUT CABLE IN with ALCN 792D Electrical Specifications Limited 24VDC 400mA max 10kHz frequency Max loop resistance 40 ohms Consumption Standby 200mA Alarm 213 mA for ALCN 792MISO circuits are power limited and must use type FPL FPLR or FPLP power limited cable wiring maximum loop resistance is 40 ohms total These lines are power limited and fully supervised to wiring instructions in the Network Fire Alarm Manual Information Quad Loop Adder Module Board TO BE USED FOR INSTALLATION PURPOSES by Interchange Way Ontario L4K 5W3 905 660 4655 905 660 4113 Witmer Industrial Estates Falls NY 14305 Free 888 660 4655 Toll Free 888 660 4113 page http www mircom com Email mail mircom com 5948

Related Files