Mircom CAT-5971 - FDX-008W KI - FDG-008 -Fan Damper Control Modules
File Preview
Click below to download for free
Click below to download for free
File Data
Name | mircom-cat-5971-fdx-008w-ki-fdg-008-fan-damper-control-modules-2760145389.pdf |
---|---|
Type | |
Size | 1.04 MB |
Downloads |
Text Preview
FAN DAMPER CONTROL MODULES FDG 008 provides switch control and LED of 8 fan damper zones provides switch control of 7 fan zones with terminals for a keyswitch board is used as a graphic driver for control and takes up two module spaces the backbox enclosure s with FleX Net FX 2000 Fire Alarm Panels and approved under the following UL 864 NFPA 72 101 90A 92A 92B Control Category automatic control of fans and or based upon smoke detector input can be set up to monitor the progress of smoke in the same manner as on a standard alarm display the switch is moved to the position the fan damper is turned on or open If the fan or damper is off or closed it will turn on or open when the is moved to the position FDX 008W KI can be connected to the main or it can be connected to the RAX LCD or RAXN LCDG Remote Shared Display FDX 008W KI takes up one frame when connected the main or remote share display and occupies one in the BB 1000 BB 5000 BBX 1000 and enclosures are two models of the Fan Damper Control modules available FDX 008W Fan Damper Module provides output circuits for Fan Damper and Purge and has 8 switches FDX 008WKI provides 7 switches and a terminal is used to connect a key switch to enable the control function FDG 008 Fan Damper Graphics Control Module the same control eight switches and LED indicators as the FDX 008W except a graphics display circuit has a slide in label and a three selector switch with Green or Yellow LED The has a centre Auto position with White system running a left or closed position a right or open position the position the fan or damper follows the alarm programming when an alarm occurs When switch is turned to the position the fan or is turned off or closed the fan or damper is normally on or open it will off or close when the switch is moved to the position Red INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY Dept NUMBER FDX 008WKI Display Module DC nominal range of 20 to 39V DC via one ribbon cable to P2 of previous module 8 configurable output circuits or fan damper controls 15mA Max Alarm all LEDs ON 35mA Max Fan Damper Graphic Control Module DC internally provided by the FX 2000 FleX Net Alarm Control Panels via one ribbon cable to P2 of previous module 8 configurable output circuits or fan damper 15mA Max Alarm all LEDs ON 35mA Max Use the FX 2000 FleX Net Fire Alarm Control Panel Manual in conjunction with this document for complete information circuit has a slide in label and a three position selector with Green or open LED Red and a LED The three position selector switch a centre Auto position with White LED system running left or closed position and a right or open Information Damper Control Display Module 8 SWITCH Damper Control Display Module 7 SWITCH KEY Damper Graphic Control Module Interchange Way Ontario L4K 5W3 905 660 4655 905 660 4113 Witmer Industrial Estates Falls NY 14305 Free 888 660 4655 Toll Free 888 660 4113 www mircom com mail mircom com INFORMATION IS FOR MARKETING PURPOSES AND NOT INTENDED TO DESCRIBE THE PRODUCTS complete and accurate technical information relating performance installation testing and certification refer technical literature This document contains intellectual of Mircom The information is subject to change by without notice Mircom does not represent or warrant or completeness 5971 1