Mircom CAT-5985 FLEXNET-MNS Mass Notification System (English)

File Preview
File Preview
Click below to download for free

Text Preview

INTELLIGENT FIRE ALARM EMERGENCY COMMUNICATIONS NETWORK Notification Storage and activation of pre programmed intelligible voice Supervision of all Mass Notification MNS equipment Auxiliary inputs for general paging background music or other Tamper resistant enclosures with password protected features for functions access control One Way and Two Way EVACS capability Automatic response to MNS inputs Local and remote controls and indicators Synchronized evacuation zone signalling Voice message priority according to risk analysis and emergency plan Visible notification and strobes support Local Operating Console FX LOC that provides on site monitoring of voice and notification appliances Large LCD displays Fire Alarm Control Panel Interface FACI Building Management System Interface BMSI Autonomous Control Unit providing real time status of all FX LOC UL 2572 Listed for Mass Notification Alarm Control Base system is expandable up to 20 SLCs Advanced Protocol AP supports up to 318 devices per SLC 159 MGC Protocol supports up to 240 MIX 4000 devices 240 sensors Four Style Z Y Class A B Notification Appliance Circuits rated at 159 modules modules per SLC Amps each Built in Ethernet port Remote diagnostics via a built in web server Control Multi channel operation Distributed audio Compatible with 520Hz low frequency signal by Mircom 5 hard wire fire fighter telephone channels that can be expanded intelligent fire phone modules 25 or 70 volt system Multiple amplifier sizes Max of 180 watts per Integrated Fire Audio panel Expansion to three 360 watts expansion cabinets for a total of 1260 of audio power per node Features Up to 63 nodes Peer to peer network communications Fully integrated digital network audio and control over a single pair copper wire or fiber optic cable Supports over 5,000 points per node Supports over 250,000 points on a single network Remote diagnostics via built in web server and standard Ethernet in every node Style 4 Class B or Style 6 or 7 Class A wiring configuration Proprietary Arcnet Network Communications protocol Dept NUMBER FleX Net Mass Notification System MNS is designed to real time information to all building occupants or personnel the immediate vicinity of a building during emergency situations system allows for real time information regarding the type of as well as safely instructing people on where to go and to do FleX Net MNS system offers building owners and facility with a simple solution to their safety requirements The is designed to automatically change as emergency situations In addition it is able to manage all mass notification allow responding authorities the ability to override fire alarm issue external voice announcements and simultaneously different emergency communications on any geographic required with the industry most advanced hardware and software FleX Net MNS system provides reliable and clear audible visual notification live voice instruction and Internet based text In addition it can be easily integrated to other public safety for emergency communications to wide area networks FleX Net MNS is UL 2572 listed for Mass Notification and with NFPA 72 2019 and UFC DOD standards for emergency systems Based on the proven and reliable FleX Net Network Fire Alarm Control Panel and Audio System the MNS provides a rich feature set that delivers an extensive of configurable options that allow for flexibility in any while reducing the installation and maintenance burden an easy to install modular setup TO BE USED FOR INSTALLATION PURPOSES INFORMATION IS FOR MARKETING PURPOSES ONLY AND INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY Mass Notification Control Modules Main Network Board FX 4000MNS main network board includes four Style Z Y Class NAC circuits The FX 4000MNS has provisions to mount up to internal adder modules and mounts in the BBX FXMNS enclosure Main Display Module DSPL 420 16TZDS Main Display Module provides a 4 line by character backlit LCD display Common Control buttons and Status Queues with selector switches and LEDs for Alarm Trouble and Monitoring with an additional 16 LED points annunciation The DSPL 420 16TZDS occupies one display position the BBX FXMNS enclosure Integrated Audio Network Chassis QMB 5000N includes the audio and telephone control which of an audio card cage designed for mounting the ANC 4000 Network Controller Module TNC 5000 Telephone Network Module and up to four QAA style audio amplifiers The connects to the FX 4000MNS Network fire alarm main and mounts in the BBX FXMNS enclosure Enclosure BBX FXMNS enclosure supports the Network main board DSPL XXXX LCD display QMB 5000N audio card QMP 5101NV Master Paging Microphone QMT 5302NV Master Telephone Handset addition the enclosure provides space for external modules and internal lobby modules The BBX FXMNS holds up to AH batteries and is available with white BBX or red BBX FXMNSR doors Dimensions 61.5 x 20 x 9 Graphical Main Display Module DSPL 2440DS Graphical Main Display Module provides the with a 24 line x 40 character backlit LCD display controls buttons and four status queues with selector and LEDs for Alarm Supervisory Trouble and Monitor The occupies one display position in the BBX FXMNS Network Master Paging Control Module QMP 5101N Network Master Paging Control Module includes the microphone and common control indicators The QMP 5101N Master Paging Control Module connects via a ribbon cable to first QAZT 5348DS or QAZT 5302DS Zoned Selector Panel and the previous display module The QMP 5101NV is vertical mount that mounts in the BBX FXMNS enclosure Main Display Module DSPL 420DS Main Display Module provides the with a 4 line by 20 character backlit LCD Common Controls buttons and Four Status Queues with switches and LEDs for Alarm Supervisory Trouble and The DSPL 420DS occupies one display position in the enclosure Network Master Firefighters Telephone Control QMT 5302NV includes the Master Telephone Handset and control indicators The QMT 5302NV supports the QAZT Paging and Telephone selector modules The QMT 5302NV a vertical mount unit that mounts in the BBX FXMNS enclosure TO BE USED FOR INSTALLATION PURPOSES INFORMATION IS FOR MARKETING PURPOSES ONLY AND INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY 5985 2 of 15 Network Controller Modules Hardwire Modules Fire Network Controller Module FNC 2000 provides network capability to the system One Fire Controller Module is required per network node panel In the FNC 2000 provides an interface for adding an optional Fiber Optic Network Adder Module The FNC 2000 in the FLEXNET MNS Eight Initiating Circuit Module DM 1008A provides 8 Style B Class B or 4 Style D Class A Circuits configurable for Alarm Supervisory or Trouble zones DM 1008A occupies one module slot Four Notification Appliance Circuit Module SGM 1004A provides 4 Style Z Y Class A B Notification Appliance configurable as Silenceable or Non Silenceable Each NAC is rated at 1.7 Amps and has individual signal silence inputs selectable The SGM 1004A occupies one module slot Fiber Card Universal Mode for single mode or multi mode fibre optic communication on a network Add FOM CONN SM and FOM CONN MM Fiber Optic Connector Multi Mode Optic Module Connector Multi mode pack of 2 Must use a Fiber Optic Connector Single Mode Optic Connector Single Mode pack of 2 Must use a Auxiliary Modules Eight Relay Circuit Module RM 1008A provides

Related Files