Mircom Fire-Link3 Datasheet

File Preview
File Preview
Click below to download for free

File Data

Name mircom-fire-link3-datasheet-6214590738.pdf
Type PDF
Size 1.47 MB
Downloads

Text Preview

WIRELESS EXTENSION FOR EMERGENCY AND FIRE ALARM SYSTEM Compatible with the following Mircom fire alarm control FleX Net FX 2000 FX 3500 FX 3318 FX 4000N and Secutron MMX MR 3500 and MR 3318 have addressable SLC loops using addressable in CLIP mode only Connects to any fire alarm panel with conventional Wireless connection to notification devices Supports Single and Two stage notification Battery backup Configurable Trouble AC Fail and alarm relay outputs UL 864 ULC S527 Listed Zone Controller ZC Zone Controller ZC manages the wired connection the FACP Fire Alarm Control Panel and the wireless with the Wireless Input Output units The ZC plugs any 120 240 VAC receptacle or the one determined by the Authority Having Jurisdiction Zone Controller relays messages between the Wireless unit and the Fire Control Panel It plugs into any 120 240 VAC receptacle the one determined by the AHJ Authority Having and has a battery backup Zone Controllers can daisy chained and installed one per zone Connection to fire panel is establish through conventional or addressable methods Frequency 2.4 GHz number of Zone Controllers per system 16 with the ZC 301W is Black back box Main board Inner chassis Front door NUMBER Fire Link3 offers a fast clean and cost effective fire alarm audible signaling solution for multi residential that are in need of a fire alarm audibility upgrade In Fire Link III is a wireless upgrade solution that installs fire alarm output devices strobes horns etc without the to add wiring to the building communications is accomplished wirelessly using extremely robust and secure mesh network technology The main system components are the Zone Controller ZC and Wireless Input Output unit WIO The Zone Controllers can daisy chained and installed one per floor in the building Controllers can be connected using either addressable or NAC bell circuits to the Fire Panel Wireless Input Output unit is a wireless base and is to be connected to Mircom and other third party appliances TO BE USED FOR INSTALLATION PURPOSES INFORMATION IS FOR MARKETING PURPOSES ONLY AND INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY WIO Input Output Unit white Wireless Input output unit is a wireless device that connects notification appliance to the Zone Controller network Wireless Input Output unit communicates wirelessly with Zone Controller and drives one notification appliance notification appliances are the following wire notification appliances manufactured by Mircom two stage is not supported System Sensor Gentex Wireless Input output unit is powered by 120 or 240 VAC has a backup battery Frequency 2.4 GHz number of Wireless Input output units per Zone is 49 number of Wireless Input output units per system 784 Dual Input Module MIX 4040 Dual Input Module is an intelligent addressable designed to be used with a MGC compatible control providing a high rate of exchanged information with fast secure responses module can be used for alarm supervisory or monitor applications MIX 4040 Dual Input module provides two 2 independent monitoring circuits only utilizing one 1 address on the loop module supports one 1 Class A or two 2 Class B inputs configured for Class A operation the module provides an EOL resistor When configured for Class B operation module monitors two 2 independent input circuits using one 1 module address address of each module is set using the MIX 4090 tool module has a panel controlled LED indicator The LED during normal operation and stays ON steadily when device is in alarm condition Dual Relay Module MIX 4045 Dual Relay Module is an intelligent addressable designed to be used with an MGC compatible control providing high rates of information exchange and fast secure responses MIX 4045 Dual Relay Module controls two independent while using only one module address module provides two form C SPDT contacts rated at 2A 30VDC or 0.5A at 125VAC and the Fire panel can control contact individually are electrically isolated from the Fire alarm panel at times contact position is verified by the module at all times If a is not at the required position during standby or active a trouble will be reported by the panel address of each module is set using the MIX 4090 tool module has a panel controlled LED indicator The LED during normal operation and stays ON steadily when device is in alarm condition Modules intelligent monitor modules are designed to meet wide range of applications The monitor modules provide interface to contact devices such as manual stations smoke or heat detectors waterflow switches more The monitor modules are addressed with easy to rotary code switches Advanced Protocol AP devices use a high speed protocol that greatly increases the speed of between the intelligent devices Mircom Protocol uses a superior group polling method as as an interrupt feature that provide for a faster response to alarm condition In addition the Advanced Protocol allows greater system capacity with support for up to 318 devices SLC circuit The AP devices are backwards compatible to in CLIP mode for legacy system applications TO BE USED FOR INSTALLATION PURPOSES INFORMATION IS FOR MARKETING PURPOSES ONLY AND INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY 6002 2 of 4 Diagram Strobe Strobe Strobe Strobe Controller Wireless Input Output unit Connection Connection Alarm Control Panel ALL EXTENDED CIRCUITS ARE SUPERVISED The Minimum Signal Strength measured by LQI Link Quality Indicator which is the quality of the received signal strength in the presence ambient noise for each WIO and ZC 301W link must be 60 A 60 LQI or higher is acceptable This measurement can be viewed via the LCD display at each Zone Controller Wireless Input Output unit WIO ratings to 49 4 to 120 93 32 non condensing Load on circuit line voltage Frequency power sensitivity BT 026 Standby Time VAC 60 Hz 193mA 240 VAC 50 Hz 124mA SUPERVISED GHz dBm dBm nominal voltage SUPERVISED 9000mAH Lithium Ion Pack Protection Circuit Transfer to battery voltage when there is AC power hours 2 hours of operation based on the connected notifi appliance candela setting 29 hours and 5 minutes of at 30mA AH batteries capability charging current 1.8 A at 24VDC REGULATED Standards and ULC S527 Control Units and Accessories in indoor and dry environment only TO BE USED FOR INSTALLATION PURPOSES INFORMATION IS FOR MARKETING PURPOSES ONLY AND INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY 6002 3 of 4 continued Zone Controller ZC ratings to 49 4 to 120 93 32 non condensing line voltage Circuits VAC 60 Hz 121mA 240 VAC 50 Hz 75mA SUPERVISED ine impedance for SLC loop is 40 ohms and for a con detection zone 100 ohms Maximum current is 2mA 1 Maximum current is 29mA GHz dBm dBm nominal voltage SUPERVISED 9000mAH Lithium Ion Pack Circuit Transfer to battery voltage when there is no AC hours AH batteries A and ULC S527 Control Units and Accessories in indoor and dry environment only Frequency power sensitivity BT 026 Standby Time capability charging Standards Information Controller Input Output Unit WHITE

Related Files