Mircom I56-3313 MIX-5251AP RAP-HAP (English)

File Preview
File Preview
Click below to download for free

File Data

Name mircom-i56-3313-mix-5251ap-rap-hap-english-5713968240.pdf
Type PDF
Size 847.50 KB
Downloads

Text Preview

25 Interchange Way Vaughan Ontario L4K 5W3 FAX 905 660 4113 inches 155 mm installed in B210LP 4.1 inches 104 mm installed in B501 inches 51 mm ounces 137 gm to 100 to 38 MIX 5251AP and MIX 5251RAP to 150 to 66 MIX 5251HAP to 93 Relative Humidity Non condensing flanged base B501 flangeless base to 32 Volts DC Peak 24 VDC one communication every 5 seconds with LED blink enabled mA 24 VDC 57 MIX 5251AP and MIX 5251RAP 190 88 MIX 5251HAP to greater than 15 MIX 5251RAP AND MAINTENANCE INSTRUCTIONS MIX 5251RAP and MIX 5251HAP Plug In Temperature Sensors Temperatures Humidity Range Range Current Current Temperature Rating of Rise Detection INSTALLING sensor must be installed in compliance with the control panel system manual The installation must meet the requirements of the Au Having Jurisdiction AHJ Sensors offer maximum performance when in compliance with the National Fire Protection Association NFPA NFPA 72 read the system wiring and installation manual thoroughly This man provides detailed information on sensor spacing placement zoning and applications Copies of these manuals are available from Mircom DESCRIPTION MIX 5251AP MIX 5251RAP and MIX 5251HAP are intelligent sen that utilize a state of the art thermistor sensing circuit for fast response sensors are designed to provide open area protection with 50 foot capability as approved by UL 521 Model MIX 5251AP is a fixed tem sensor with 135 fixed temperature alarm Model MIX 5251RAP is rate of rise temperature sensor with 135 fixed temperature alarm Model is a high temperature sensor with 190 fixed temperature LEDs on each sensor light to provide 360 visibility of the sensor indica The LEDs can be latched ON by code command from the panel for an indication The LEDs can also be unlatched to the normal condition code command Remote LED annunciator capability is available as an accessory Part No RA400Z RA100Z MIX 5251AP MIX 5251RAP and MIX 5251HAP require compat addressable communications to function properly Connect these to listed compatible control panels only GUIDE wiring must be installed in compliance with the National Electrical Code local codes and the Authority Having Jurisdiction Proper wire should be used The installation wires should be color coded to limit mistakes and ease system troubleshooting Improper connections will a system from responding properly in the event of a fire power from the communication line before installing sensors Wire the sensor base supplied separately per the wiring diagram see 1 Set the desired address on the sensor address switches see Figure 2 Install the sensor into the sensor base Push the sensor into the base turning it clockwise to secure it in place After all sensors have been installed apply power to the control unit and the communication line Test the sensor s as described in the TESTING section of this manual RESISTANCE sensor bases have a tamper resistant capability When this capability is sensors cannot be removed from the base without the use of a small or other similar tool Refer to the sensor base installation instruc manual for details in using this capability testing notify the proper authorities that the system is undergoing and will temporarily be out of service Disable the system to unwanted alarms sensors must be tested after installation and periodically thereafter Test methods must satisfy the Authority Having Jurisdiction AHJ Sensors maximum performance when tested and maintained in compliance with 72 The sensor may be tested in the following ways TEST MAGNET MODEL NO M02 04 Place the magnet against the cover in the magnet test area as in Figure 3 to activate the test feature The LEDs should latch ON within 10 seconds indicating alarm and the panel Reset the detector at the system control panel DIRECT HEAT METHOD HAIR DRyER OF 1000 1500 WATTS From the side of the detector direct the heat toward the sensor Hold heat source about 6 inches 15cm away to prevent damage to cover during testing The LEDs on the detector should light when the temperature at the reaches the alarm set point If the LEDs fail to light check power to the detector and the wiring in the detector base Reset the detector at the system control panel that fail these tests should be cleaned as described under MAIN and retested If the detectors still fail these tests they should be for repair Before cleaning notify the proper authorities that the system is un maintenance and therefore the system will temporarily be out of Disable the loop or system undergoing maintenance to prevent un alarms is recommended that the sensor be removed from its mounting base for cleaning and that sensors be cleaned at least once a year Use a vac cleaner to remove dust from the sensing chamber 1 2 ROTARy DECADE ADDRESS SWITCHES DO NOT LOOP WIRE TERMINAL 1 OR 2 WIRE RUN TO PROVIDE OF CONNECTIONS 0 0 A OPTIONAL WIRING 3 VIEWS SHOWING POSITION OF TEST MAGNET 4 MAGNET CLASSIFICATION ratings are for installations which must comply with FM 3210 RTI RTI RTI refer to insert for the Limitations of Fire Alarm Systems STATEMENT device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installa If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Mircom

Related Files