INSTALLATION AND MAINTENANCE INSTRUCTIONS Interchange Way Vaughan Ontario L4K 5W3 905.660.4655 Fax 905.660.4113 to 32 VDC LED On max 1 communication every 5 seconds 47k EOL resistor 485 uA max Communicating NAC shorted VDC Supervised Control Module Operating Voltage Alarm Current Operating Current NAC Line Loss Supply Voltage between Terminals T3 and T4 NAC Speakers NAC Current Ratings Range 24VDC V RMS 50 W class B wiring system the current rating is 3A For class A wiring system the current rating is 2A to 120 0 to 49 to 93 Non condensing H 4 W 11 4 D Mounts to a 4 square by 21 8 deep box Electrical Box CB500 Barrier 2A MODULE MOUNTINg fIgURE 2B BARRIER INSTALLINg information is included as a quick reference installation guide Refer to control panel installation manual for detailed system information If the will be installed in an existing operational system inform the opera and local authority that the system will be temporarily out of service Dis power to the control panel before installing the modules This manual should be left with the owner user of this equipment DESCRIPTION Supervised Control Modules are intended for use in intelli two wire systems where the individual address of each module is se using the built in rotary decade switches This module is used to switch external power supply which can be a DC power supply or an audio ampli up to 80 VRMS to notification appliances It also supervises the wiring the connected loads and reports their status to the panel as NORMAL or SHORT CIRCUIT The MIX M500SAP has two pairs of output ter points available for fault tolerant wiring and a panel controlled LED REqUIREMENTS ensure proper operation these modules shall be connected to listed com system control panels only 1 CONTROLS AND 1B jUMPER LOCA MIX M500SAP mounts directly to 4 inch square electrical boxes see 2A The box must have a minimum depth of 21 8 inches Surface electrical boxes SMB500 are available from System Sensor All wiring must conform to applicable local codes ordinances and When using control modules in nonpower limited applications System Sensor CB500 Module Barrier must be used to meet UL require for the separation of power limited and nonpower limited terminals and The barrier must be inserted into a 4 junction box and the module must be placed into the barrier and attached to the junction Figure 2A The power limited wiring must be placed into the isolated of the module barrier Figure 2B Install module wiring in accordance with the job drawings and appropri wiring diagrams Set the address on the module per job drawings Secure module to electrical box supplied by installer as shown in Fig 2A When using the MIX M500SAP for fire fighter telephone ap remove Jumper J1 and discard The Jumper is located on the as shown in figure 1B The module does not provide ring back when as a fire fighter telephone circuit 3 TyPICAL NOTIfICATION APPLIANCE CIRCUIT CONfIgURATION NfPA STyLE y NOT LOOP WIRE ON TERMINALS 10 11 BREAK WIRE TO PROVIDE SUPERVISION OF CONNECTIONS VDC CIRCUIT MODULES TO COMPATIBLE PANELS ONLY VDC POWER SUPPLY REGULATED LIMITED PER NFPA 70 FOR FIRE PROTECTION BATTERY BACKUP POLARITIES ARE IN ALARM EOL LISTED EOL RELAY ENERGIZED VDC COIL EOLR 1 NEXT CONTROL MODULE OR END OF LINE ONE RELAY REQUIRED FOR EACH SOME CONTROL PANELS HAVE RELAY IN AND DO NOT REQUIRE EXTERNAL REFER TO PANEL MANUAL OR LINE CIRCUIT SLC VDC MAX PAIR RECOMMENDED WIRING SHOWN IS SUPERVISED POWER LIMITED NEXT ANY FAULT IN THE POWER SUPPLY IS TO THAT ZONE AND DOES NOT IN A FAULT IN A SEPARATE ZONE MODULES TO LISTED CONTROL PANELS ONLY OR 4 TyPICAL fAULT TOLERANT NOTIfICATION APPLIANCE CIRCUIT CONfIgURATION NfPA STyLE Z VDC POWER SUPPLY REGULATED POWER PER NFPA 70 LISTED FIRE PROTECTION WITH BACKUP VDC CIRCUIT NOT LOOP WIRE ON TERMINALS 10 11 WIRE RUN TO PROVIDE SUPERVISION CONNECTIONS POLARITIES ARE IN ALARM RESISTOR INTERNAL AT 9 LISTED EOL SHOWN VDC COIL NEXT CONTROL MODULE OR RELAY ONE RELAY FOR EACH CIRCUIT CONTROL PANELS HAVE BUILT IN AND DO NOT EXTERNAL WIRING TO PANEL MANUAL LINE CIRCUIT SLC VDC MAX TWISTED PAIR RECOMMENDED WIRING SHOWN IS SUPERVISED POWER LIMITED ANY FAULT IN THE POWER SUPPLY LIMITED TO THAT ZONE AND DOES NOT IN A FAULT IN A SEPARATE ZONE 5 TyPICAL wIRINg fOR SPEAkER SUPERvISION AND SwITChINg NfPA STyLE y CIRCUIT WIRING MUST BE TWISTED PAIR AS A MINIMUM SEE PANEL INSTALLATION MANUAL FOR DETAILED INFORMATION CIRCUIT NOT LOOP WIRE AROUND TERMINALS 11 BREAK WIRE TO ENSURE OF CONNECTIONS AMPLIFIER 70.7 Vrms MAX MUST PROVIDE WIRING PER NFPA EOL POLARITIES ARE IN ALARM MUST BE PER NFPA MODULES TO LISTED COMPATIBLE PANELS ONLY PANEL OR DEVICE LINE CIRCUIT SLC VDC MAX PAIR RECOMMENDED NEXT NEXT CONTROL MODULE MODULE MUST RETURN FOR SUPERVISION MUST BE LISTED FOR FIRE REFER TO THE RELAY CONTACT TABLE FOR MAXIMUM LOAD ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE 6 TyPICAL fAULT TOLERANT wIRINg fOR SPEAkER SUPERvISION AND SwITChINg NfPA STyLE Z CIRCUIT WIRING MUST BE TWISTED PAIR AS A MINIMUM SEE PANEL INSTALLATION MANUAL FOR DETAILED INFORMATION MODULES TO LISTED COMPATIBLE CONTROL PANELS ONLY NOT LOOP WIRE AROUND TERMINALS CIRCUIT MUST BE 11 BREAK WIRE TO ENSURE OF CONNECTIONS PER NFPA OR AMPLIFIER 70.7 Vrms MAX MUST PROVIDE WIRING PER NFPA EOL RESISTOR INTERNAL AT 8 9 CAPACITORS 100 NONPOLARIZED LEAKAGE POLARITIES ARE IN ALARM NEXT CONTROL MODULE MODULE MUST RETURN FOR SUPERVISION ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE LINE CIRCUIT SLC VDC MAX PAIR RECOMMENDED WIRING SHOWN IS SUPERVISED POWER LIMITED NEXT MUST BE LISTED FOR PROTECTION REFER TO THE CONTACT RATING TABLE MAXIMUM LOAD relay switch contacts are shipped in the standby state open state but may have transferred to the activated closed state during shipping To ensure the switch contacts are in their correct state modules must be made to communicate with the panel before connecting circuits controlled by the module Mircom

Related Files