Mircom I56-3326 MIX-M502MAPA (English)

File Preview
File Preview
Click below to download for free

File Data

Name mircom-i56-3326-mix-m502mapa-english-0251837649.pdf
Type PDF
Size 1.30 MB
Downloads

Text Preview

INSTALLATION AND MAINTENANCE INSTRUCTIONS Interchange Way Vaughan Ontario L4K 5W3 905.660.4655 Fax 905.660.4113 DC Voltage Voltage VDC power limited Volts RMS maximum per module to 120 0 to 49 to 93 Non condensing H x 4 W x 11 D Mounts to a 4 square by 21 deep box Electrical Box Interface Module Operating Voltage to 32 VDC Alarm Current LED on Operating Current 1 communication and 1 LED flash every 5 seconds 3.9k eol Resistance Ohms IDC wiring resistance Ohms Supply Voltage between Terminals T3 and T4 Range Installing information is included as a quick reference installation Refer to the control panel installation manual for detailed information If the modules will be installed in an existing system inform the operator and local authority that system will be temporarily out of service Disconnect power to control panel before installing the modules This manual should be left with the owner user of this Description MIX M502MAPA Interface Module is intended for use in in two wire systems where the individual address of each is selected using the built in rotary decade switches This allows intelligent panels to interface and monitor two wire smoke detectors It transmits the status normal or alarm of one full zone of conventional detectors back the control panel All two wire detectors being monitored must ULC compatible with this module The MIX M502MAPA has a controlled LED indicator Requirements ensure proper operation these modules shall be connected to compatible system control panels only MIX M502MAPA mounts directly to 4 square electrical boxes Figure 2A The box must have a minimum depth of 21 Sur mounted electrical boxes SMB500 are available from Mir 2A Module mounting barrier wiring diagrams in Figure 2A 2B All wiring must conform to applicable local codes ordi and regulations This module is intended for power lim wiring only Install module wiring in accordance with the job drawings and Set the address on the module per job drawings Secure module to electrical box supplied by installer as 1 Controls and indicators Two wire System Sensor Smoke Detectors for Use with MIX M502MAPA with Zone Identifier A with Thermal with Thermal ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE 3 Interface two wire conventional detectors NFPA Style B TO THE INTERFACE MODULE MUST EXTERNALLY SWITCED TO RESET THE AN MIX M500RAPA RELAY MODULE CAN BE USED TO SWITCH FROM A STANDARD POWER SUPPLY FIGURE 5 BRANCH CIRCUIT NEXT INTERFACE MODULE SUPERVISES SUPPLY AND DETECTOR LOOP NEXT BATTERY BACKUP SWITCHED DC POWER SUPPLY PANEL OR DEVICE LINE CIRCUIT SLC VDC MAX PAIR RECOMMENDED EOL NOT LOOP WIRE UNDER TERMINALS BREAK ALL WIRE TO PROVIDE SUPERVISION OF CONNECTIONS MUST BE ULC LISTED COMPATIBLE WITH INSTALL DETECTORS PER MANUFACTURER INSTRUCTIONS MODULES TO LISTED CONTROL PANELS ONLY WIRING MUST BE POWER LIMITED NOT MIX FIRE ALARM INITIATING SUPERVISORY SECURITY DEVICES ON THE SAME MODULE 4 Interface two wire conventional detectors NFPA Style D TO THE INTERFACE MODULE MUST EXTERNALLY SWITCED TO RESET THE AN MIX M500RAPA RELAY MODULE CAN BE USED TO POWER FROM A STANDARD POWER SEE FIGURE 5 BRANCH CIRCUIT NEXT INTERFACE MODULE SUPERVISES SUPPLY AND DETECTOR LOOP NEXT PANEL OR DEVICE LINE CIRCUIT SLC VDC MAX PAIR RECOMMENDED MODULES TO LISTED CONTROL PANELS ONLY WIRING MUST BE POWER LIMITED NOT MIX FIRE ALARM INITIATING SUPERVISORY SECURITY DEVICES ON THE SAME MODULE BATTERY BACKUP REGUALTED POWER SUPPLY EOL RESISTOR AT TERMINALS 9 INCLUDED A2143 10 NOT LOOP WIRE UNDER TERMINALS BREAK ALL WIRE TO PROVIDE SUPERVISION OF CONNECTIONS MUST BE ULC LISTED COMPATIBLE WITH INSTALL DETECTORS PER MANUFACTURER INSTRUCTIONS 5 Relay control module used to disconnect a power supply ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE NEXT LIMITED DC SUPPLY FOR FIRE WITH BACKUP CONTROL PANEL OR DEVICE LINE CIRCUIT SLC VDC MAX PAIR RECOMMENDED MODULES TO LISTED CONTROL PANELS ONLY ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE 2008 Mircom

Related Files