Mircom LT-1200 FA-103 and FA-106 Installation Manual (English)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | mircom-lt-1200-fa-103-and-fa-106-installation-manual-english-1254803976.pdf |
---|---|
Type | |
Size | 2.66 MB |
Downloads |
Text Preview
Advanced Life Safety Solutions and FA 106 Alarm Control Panels and Operation Manual Rev 2 2018 of Contents Fire Alarm Control Panel 1 Installation 1 for Wiring 4 4 SWITCH SELECTION 5 6 IDC Zones 6 NAC Zones 6 and Trouble Relays 6 Annunciation 6 Power and Batteries 6 Tables and Information 9 Indicators and Controls 11 Trouble LED 11 Silence Pushbutton 11 Zone Trouble LED 11 Fault LED 11 Fault LED 11 Zone Disable 11 of Operation 12 12 12 silence SIG SIL 12 12 Test 12 Checkout 12 up and Troubleshooting 12 A Electrical Specifications 13 B Compatible Devices 14 C Battery Calculations Selection Guide 16 and Warning Information 17 of Figures 1 Backbox and flush trim mounting details 2 2 Assembly of FA 106 and FA 103 Fire Alarm Panels 3 3 Conduits for Wiring 4 4 Setting the DIP Switch functions 5 5 A C Power and Battery Connection 6 6 Circuit Board Layout 7 7 Detection and signal wiring 8 8 Alarm and trouble relay contacts remote annunciation and four wire detector instructions 10 9 Front Panel Display 11 Installation and Operation Manual FA 106 is a supervised six zone 24VDC Fire Alarm Control Panel The FA 103 is a supervised three zone Fire Alarm Control Panel The panels are ULC listed and meet all performance and operational of ULC The FA 106 provides the following features Six Class B Style B detection IDC zones Two Class B Style Y signal zones NACs 1.25A max per zone 2A max total DIP switch selectable NAC outputs such as Temporal or Steady Alarm and trouble relay contacts Remote trouble buzzer and indication with the use of an RTI 1 Remote Indicator Buzzer silence button Subsequent alarm operation LED indicators for zone alarm and trouble A C Power On Common Trouble Ground Fault Battery Fault zone silence disable switch Fault Signal Silenced and Common Alarm FA 103 has the same features as above except there are only three detections zones The enclosures and are identical except the FA 103 is depopulated and has terminal connections for three detection zones Use of the reference panel will apply to both models FA 106 and FA 103 available are detection zones two NACs FACP with white door and black backbox detection zones two NACs FACP with red door and black backbox detection zones two NACs FACP with white door and black backbox detection zones two NACs FACP with red door and black backbox Installation panel can be surface or flush mounted Refer to Figure 1 on page 2 for dimensions Mounting Mark the location of the four mounting holes the top two screws into the wall and place the panel over the screws the bottom screws and tighten down all four screws Mounting Make the wall cut out according to the panel dimensions Remove the control panel door Mount the flush mounting trim model FA 102TR to the back box using the screws and nuts provided with Re install the door on top of the flush trim The cam lock may require a minor adjustment in order to flush mounting kit for the flush trim 1 Backbox and flush trim mounting details flush trim FA 102TR 11 16 3 4 3 8 7 dia holes 1 4 1 8 3 4 7 8 2 Assembly of FA 106 and FA 103 Fire Alarm Panels Dead Front Front Door power must be run through a dedicated conduit in knockouts A or B shown in Figure 3 All other circuits are limited and must be run through knockouts C or D Installation for Wiring 3 Conduits for Wiring controls shall be no less than 600 mm and no more than 1800 mm above the finished floor SWITCH SELECTION Installation and Operation Manual switch SW12 is used to set the preferred signal zone outputs the signal silence inhibit the detection zone and auxiliary functions DIP switch SW12 is located in the bottom right corner of the main printed board refer to Figure 6 on page 7 4 Setting the DIP Switch functions switch SW12 NAC Zone 1 Steady