Mircom LT-1202 FX-3318 Installation and Operation Manual (English)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | mircom-lt-1202-fx-3318-installation-and-operation-manual-english-8319745026.pdf |
---|---|
Type | |
Size | 1.10 MB |
Downloads |
Text Preview
SINGLE LOOP INTELLIGENT FIRE ALARM CONTROL PANEL One onboard SLC communication circuit Optional City Tie Polarity Reversal module for central up to 318 intelligent devices in AP mode Clip support of up to 198 devices Dialer Module for remote monitoring x 20 LCD with 80 characters up to 7 annunciators monitoring field installable Power Limited Class B Style Y or Class A Style NAC circuits max 1.5 Amps each 5.0 amps total power is available in the form of 24V FWR and unsupervised 24VDC filtered and and resettable auxiliary power supply Alarm Sequence PAS provides an alarm of up to 180 seconds if an alarm is acknowledge the control panel within 15 seconds This action the responding personnel time to investigate alarm before evacuating a building sync strobe protocols from major alarm verification waterflow retard and alarm sequence operations Configurable Signal Silence Inhibit Auto Signal and One Man Walk Test FX 3318 Addressable Fire Alarm Control Panel an intelligent addressable multi zoned panel with value while not compromising the Mircom needed to satisfy small to medium jobs FX 3318 is shipped pre assembled with all main including main board power supply and main display in a red enclosure built in dialer is included to communicate panel status the remote central monitoring station using 2 dedicated lines Both SIA and Contact ID are supported to 7 annunciators can be added with enclosure options red white or NEW stainless steel has one built in signaling line circuit SLC With Mircom Protocol AP a superior group polling method well as an interrupt feature allows a faster response to alarm The AP or Advanced Protocol allows for greater capacity with support for up to 318 devices in AP and offers legacy CLIP support of up to 198 devices has four Power Limited Class B Style Y or Class Style Z NAC circuits NAC circuits may be configured as silenceable signal non signal silenceable strobes non silenceable or relay output The audible signal may be Steady Code California Code or March Time Sync protocols are supported from major manufacturers built in trim ring accommodates both retrofits and new reducing time with semi flush or surface mountable panel is UL 9th edition listed and has COA and CSFM Dept edition 864 6288 INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY NUMBER Interfaces and Controls control buttons with associated LEDs button Numeric Keypad with cursor buttons Display display is a four line 4 x 20 80 character back lit LCD It displays information regarding the panel its circuits and Report information provided by the LCD display includes Alarm Log Event Log Current Levels Device Information Verification and Maintenance Reports 12 AH and BAT 12V18A 18 AH will fit into the enclosure To house BAT 12V26A 26 AH batteries a Battery Cabinet is required Use of alternative batteries result in failure of the panel to meet agency and regulatory and may result in shortened battery life Batteries be tested regularly and replaced at least every three years PROTOCOL AND CLIP DEVICES Maximum Loop Current 350mA Maximum Loop Resistance 40 ohms Maximum Loop Capacitance 0.5uF Maximum number of isolators 20 Listings and Approvals Rev 9 NFPA 70 72 CSFM and COA Receivers FX 3318 is compatible with the following Digital Alarm Communicator Receivers Specifications Receiver MLR2 Multi Line Receiver ULI approved SLR Single Line Receiver ULI approved Quickalert II Receiver ULI approved OH 2000 Receiver ULI approved Knight Model 9500 Receiver ULI approved Model D6500 Receiver ULI approved Model D6600 Receiver ULI approved SurGard System III Receiver ULI approved SurGard System IV Receiver ULI approved Please refer to manual Protocols Format Protocol and SIA Contact ID Format Protocol and SIA Contact ID Format Protocol and SIA Contact ID Format Protocol and SIA Contact ID Format Protocol and SIA Contact ID Format Protocol and SIA Contact ID Format Protocol and SIA Contact ID Contact ID Contact ID Capacity Signaling Line Circuits device capacity Software Zones Annunciators Devices Specifications Power 120 VAC 60Hz 240 VAC 50 Hz Wire size minimum 14 AWG 2.08mm2 with 600v insulation Fire alarm systems be installed in compliance with local codes and standards and with the Authority Having Jurisdiction AHJ Power Auxiliary power is available in the form of 24V FWR unfiltered and unsupervised 24VDC filtered and regulated resettable auxiliary power supply Supply Rating 29VAC 6A secondary of transformer 120 VAC 60Hz 1.6 Amp maximum primary of transformer 240 50 Hz 0.9 Amp maximum primary of transformer Total load not to exceed 5A 24VDC Charger Capacity 10AH 24AH charging capability Charging current 1.575A maximum Protection 10A on board slow fuse not field replaceable Stand by current rating at full load 0.7A Loop Supervised and power limited Appliance Circuits Refer to manual for all details Limited NAC circuits max 1.5 Amps each 5.0 Amps total if no auxillary power is used circuits with multiple strobes horns in one open area needs to be synchronized INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY 5686 2 of 4 Specifications cont WIRING RUN TO LAST DEVICE ELR 30 15 Loops Device Wiring protocol mode with one loop with 159 addressable sensors and 159 addressable modules per loop CLIP mode with loop with 99 addressable sensors and 99 addressable modules per loop The addressable loop may be configured as Class or Class B operation Maximum loop resistance depends on number of devices and device type Power Limited 22VDC alarm maximum 0.5 Power Limited 22VDC 280mA normal standby maximum 0.5 Specifications of Enclosure built in trim ring Dimensions of for Flush or surface mounting with a built in trim ring W x 5.78 D x 23 L W x 4.25 D x 21 L and Humidity Ranges Temperature 32 to 120 0 to 49 to 93 relative humidity non INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY 5686 3 of 4 Information Adder Modules backbox and red door enclosure Comes complete with main board power supply and main display Annunciator with 4 line LCD display Annunciator with 4 Line LCD display Relay module with red enclosure Can support up to 12 relays Point remote annunciator chassis with 16 trouble LED Point Remote Annunciator with 32 Trouble LED Annunciator Annunciator Adder Driver board reversal and city tie module Supply interface board Use for powering 3G4010 and 3G4010CF universal wireless communicator for Remote Annunciators Enclosure Houses 1 module White Enclosure Houses 1 module Red Enclosure Houses 1 module Stainless Steel Enclosure Houses 2 modules White Enclosure Houses 2 modules Red