Mircom LT-6146--MIX-4090 Device Programmer Installation Manual - English
File Preview
Click below to download for free
Click below to download for free
File Data
Name | mircom-lt-6146-mix-4090-device-programmer-installation-manual-english-9754381062.pdf |
---|---|
Type | |
Size | 1.39 MB |
Downloads |
Text Preview
AND MAINTENANCE INSTRUCTIONS DEVICE PROGRAMMER THIS MANUAL manual is included as a quick reference for use of the device to addresses on sensors and modules in the MIX 4000 series is easily accessible through a sliding cover at the bottom of unit shown in figure 2 2 PROGRAMMER BACK Interchange way Vaughan Ontario L4K 5W3 905.660.4655 Fax 905.660.4113 www mircom com This manual should be left with the owner operator of this MIX 4090 programmer is used to set or read addresses of MIX devices It can also read devices parameters such as device firmware version condition and thermal settings The is small and lightweight and has a built in base for heat smoke detectors see figure 2 A plug in cable is supplied to permanently wired devices see figure 4 Basic functions are accessible through four keys Read Write Up and Down A 2 8 characters LCD will display all required information without need an external screen or PC see figure 1 1 PROGRAMMER FRONT 9V Battery cover programming Devices with bases Do not disconnect a device during address storing This may damage the device the device in the programmer base with the bar on the about 3 8 7mm to the right of the bar on the base The should drop in the base without effort Push on the device and it clockwise until the two bars are aligned see figure 3 3 ALIGN BARS unit uses an inexpensive 9V PP3 size 6LR61 1604A alkaline and will automatically shut down when the unit is unused for than 30 seconds Start up time is only 5 seconds Remaining capacity will be displayed each time the device is used The 5 CABLE ATTACHMENT TO DEVICE on any key to start the process see figure 1 for key locations programmer will start up and will display the last address that read or written To read the current device address press on the key showing a magnifier and red X If the address has to be use the up and down keys at the left To program the address in the device press on the Write key showing a paper symbol and a green check mark the address is programmed in the device remove it from the by twisting it counter clockwise Most projects require a device address must be visible for inspection MIX 4000 bases a breakable tab that can be inserted on the outside of the base show the address See MIX 40XX installation sheet for details programming Permanently installed devices Do not disconnect a device during address storing This may damage the device the programming cable in the MIX 4090 using the connector on shown in figure 4 Locate the programming connector on the see figure 5 If the device is already installed it may be to remove the wall plate covering the device to access the 4 PROGRAMMER CABLE ATTACHMENT device parameters device parameters can be read though the MIX 4090 First the device must be connected to the programmer described for address setting After the programmer is turned on is showing the address screen press on the key for five seconds The message Analog should appear Conv is shown use the up down keys to get to Analog When done press on the key to enter the sub following parameters can then be accessed using the up and keys type followed by device type See table for a full list of devices Mircom should be displayed This parameter is not used remaining battery capacity Date followed by date of device testing in Date followed by date of device the device has to be replaced there is no need to disconnect from it However the whole SLC line should be disconnected the loop driver when devices are programmed while in place If SLC line is powered the programmer may be unable to read or the device data the cable to the device see figure 5 Please note that the plug is polarized to ensure that it is inserted in the cor position Then proceed as above to read and set addresses done use a pen or labels to indicate the device address as by the project Significant for Photo detectors only Brand new should be around 000 A value near 100 that device must be cleaned or replaced value followed by a number for detectors only normal value is around 32 0 or a value over 192 alarm threshold may indicate defective or dirty device version followed by number mode Mode followed by Enter Pressing the key will display a number showing the mode of the device This parameter should be accessed when requested by a Mircom Tech operator Modifying this parameter may make the unusable messages programmer can display the following messages during Error Device or programmer has failed and may replacement A parameter is written into the device not disconnect a device during this operation Stored Address has been successfully stored device Current operation first line of display has failed Dev The device has not responded to current Check connections or replace device Addr No address is programmed This may happen brand new devices address is read without prior write Batt Battery should be replaced 1 Device type returned by MIX 4090 programmer Module Module Zon B L Electric smoke detector detector Electric smoke and heat detector module output module output module zone module I O device point or ceiling audible NAC audible NAC and strobe visible indicator message can be returned for newer not yet in the programmer list 2 Compatible devices smoke detector smoke Heat Multi sensor detector output module input module input mini module zone module and 4 20mA relay module number