Mircom LT-657 FX-2000 Installation and Operation Manual (English)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | mircom-lt-657-fx-2000-installation-and-operation-manual-english-0574138692.pdf |
---|---|
Type | |
Size | 2.99 MB |
Downloads |
Text Preview
FX 2000 Analog Fire Alarm Control Panel and Operation Manual Rev 15 2016 the latest compatability information visit www mircom com deviceguide of Contents Conventions Components and Chassis Installation Mounting Locations and Adder Modules Mounting Locations Compact Main Chassis 25 Mid size Main Chassis 25 Large Main Chassis 26 Expander Chassis for FX 2009 12DS 26 Settings Fire Alarm Modules MD 764 Part of Main Chassis 29 Fire Alarm Super Module MD 757 Part of Version Main Chassis 30 Zone Display Module 32 Programmable Input Switches Module 32 Damper Control Display Module FDX 008W WKI 33 Hardwire Detection Adder Module 36 Hardwire NAC Signal Adder Module 37 Hardwire Relay Adder Module 39 Reversal and City Tie Module Model PR 300 40 Main Board 41 Hardwire Loop Controller Module 47 Wiring Fire Alarm Module Terminal Connections 49 Loop Wiring 51 Signal Module SGM 1004A Terminal Connections 58 Main Board Terminal Connections 61 Tables and Information 63 Checkout and Controls Stage Operation 72 Stage Operation 73 Operation 74 feature 74 Circuit Delay Operation 74 Types 75 A Specifications B Compatible Devices Series Compatible Addressable Loop Devices UL 85 Series Compatible Two Wire Smoke Detectors UL 86 Series Compatible Four Wire Smoke Detectors UL Listed 88 Series Compatible Signalling Devices UL Listed 88 Series Compatible Addressable Loop Devices ULC 89 Series Compatible Hardwire Smoke Detectors ULC 90 Series Compatible Synchronized Modules and Strobes 91 C Power Supply and Battery Calculations D Remote Annunciator Panels E DIP Switch Settings Summary F Alarm Verification Timing G Wiring For Supervised Output Module H Label Requirements for Zone Identification 100 Introduction About the FX 2000 cost effective FX 2000 Intelligent Analog Fire Alarm Control Panel FACP is a and easy to use analog system The FX 2000 base panel consists of one intelligent loop controller capable of supporting 99 analog sensors and 99 addressable modules can be wired in Class A Style 6 or 7 or Class B Style 4 Analog sensors and modules consist of all compatibility listed devices including Advanced Protocol Loop adder modules are available for additional addressable SLC loops The ALC provides one additional addressable loop and the ALC 396S provides two addressable each capable of supporting 99 analog sensors and 99 addressable modules In addition base panel supports up to 16 conventional adder modules such as the DM 1008A Initiating Module SGM 1004A NAC Circuit Module and the RM 1008A Relay Circuit Module base panel also includes 4 Class A B Style Z Y NAC circuits rated at 1.7 amperes each either a 6 or 12 ampere power supply The ALC H16 adder board provides expansion for additional conventional hardwire modules Overall Features system capacity and modular design Analog Loop is capable of supporting 99 analog sensors and 99 addressable which can be wired as Class A Style 6 or 7 or Class B Style 4 base system supports 16 conventional hardwire adder modules or 12 Ampere Power Supply Class A B Style Z Y NAC Circuits rated at 1.7 Amperes each which can be as Audible or Visual silenceable or non silenceable circuits Audibles may steady Temporal Code California Code or March Time NAC circuits may be configured to provide additional auxiliary power or resettable power isolators are present on all in panel addressable loops Configurable Signal Silence Inhibit Auto Signal Silence Two Stage Operation One Walk Test Outputs for 4 Wire resettable Smoke Power Supply Auxiliary Power Supply and an to the Mircom RTI Remote Trouble Indicator RS 485 Interface for Remote Multiplex Annunciators Level Password Protection with field settable definition which enables the installer determine what functions are accessible for each of the three levels of pass queues for Alarm ACK Supervisory ACK Trouble ACK and BLDG Monitor ACK LED indicators and selector keys Form C Relay Contacts for Common Alarm Common Supervisory and Trouble RS 232 Port for remote system printer or terminal Event History Logs one for Alarm related events and one for all events Panel Auto Configure and or Personal Computer Configuration 4 line by 20 character alphanumeric back lit LCD Display with user friendly menu Common controls and indicators for System Reset Lamp Test Fire Drill Signal Silence Alarm General Alarm Cancel AC On Pre Alarm and Ground Fault Spare configurable Keys and LED Indicators configurable LEDs bi coloured with slide in labels available with the DSPL 420 display drift compensation for photoelectric smoke detectors Signal Coding of signal circuits for easy alarm identification code consists of 1 4 digits each digit consisting of 1 15 pulses on the signal for Canadian ULC or USA ULI requirements for Smoke Sensor sensitivity transient protection Mountable Enclosures with removable doors for easy installation and service Trims available Removable Terminal Blocks for easy wiring and service Adder modules ALC 198S and ALC 396S for expanding addressable loops by 1 2 respectively module ALC H16 hardwire loop interface board for expanding conventional input relay capability Document Conventions Circuits and Zones Conventions term circuits refers to an actual electrical interface initiating detection NAC signal or term zone is a logical concept for a fire alarm protected area and will consist of at least circuit the terms zone and circuit are used interchangeably but in this