Mircom lt- 6660 MS-400MP Installation Manual

File Preview
File Preview
Click below to download for free

File Data

Name mircom-lt-6660-ms-400mp-installation-manual-3681425970.pdf
Type PDF
Size 910.05 KB
Downloads

Text Preview

Mircom MS 400MP U Series Fire Alarm Manual Stations manual fire alarm activation These high quality extruded stations are available as one stage or two stage On the two stage model a keyswitch allows the of the stage two alarm Each station has a permanently MP Mircom Protocol addressable module which is with a tool see LT 6146 MIX 4090 Device for instructions Dimensions Operating Voltage 15 30 VDC with Mircom Fire Alarm Control Panels Rating Maximum alarm current 3.3 mA of aluminum body H x 3.3 W x 0.762 D current 2 mA Wire as shown so that supervision of connections is Maximum wire size 12 AWG All manual fire alarm stations shall be installed as per the requirements outlined in the UL ULC codes as well all other applicable national or local codes Final acceptance is subject to the local authority having the manual station guide covers these models MS 401MP U Intelligent Single Stage Manual Station MP MS 402MP Intelligent Two Stage Manual Station MP MS 407MP U Intelligent Single Stage Manual Station MP additional N C switch suffix U indicates a USA version of kit MS 401MP U MS 407MP U 2 mounting screws MS 402MP 2 mounting screws 2 stage two keys separately rod or break glass Mircom part number GL 004K Series Alarm Manual Station Wiring The maximum wire size is 12 AWG Connect the black wire from the previous station to terminal that is connected to the black wire from addressable module Connect the black wire leading the next station to the side of the terminal that is connected to the black wire from the addressable module The wires must be on opposite sides of the set screw to Figure 2 for the location of the wires Tighten the terminal Connect the red wire from the previous station to the that is connected to the red wire from the module Connect the red wire leading to the next station to the side of the terminal that is connected to the red from the addressable module The wires must be on opposite sides of the set screw to Figure 2 for the location of the wires Tighten the terminal NEXT STATION OR END LINE DEVICE FUNCTION CLOSED SWITCH ONLY 1 Wiring Diagram BOTH ON SIDES THE SET SCREW BOTH ON THE SIDE OF SET SCREW BLACK RED ADDRESSABLE ADDRESSABLE Interchange Way ON L4K 5W3 1 888 647 2665 Witmer Industrial Estates Falls NY 14305 1 888 647 2665 2 Close up of terminals showing correct wiring LT 6660 Rev 3 July 2020 Series Alarm Manual Station the stage two alarm MS 402MP only the stage two key into the keyhole inside the station then turn the key This keyhole is accessible only after alarm handle has been pulled stage two alarm activates immediately The stage two alarm will activate automatically a certain of time after the handle has been pulled if no is taken This time is set in the Fire Alarm Control the manual station Resetting the station does not cancel the alarm at the a small flathead screwdriver into the hole in the front of handle Make sure that the end of the screwdriver is on top of the latch inside the station The screwdriver push down this latch order for the handle to close Close the handle and at the same time move the handle of screwdriver up See Figure 4 you close the handle the screwdriver acts as a lever to the latch down allowing the handle to close will hear a click when the handle is closed and the station reset the plastic rod break glass into the hole on the right See Figure 4 Reset the Fire Alarm Control Panel to cancel the alarm Setting the addressable module the instructions in LT 6146 MIX 4090 Device Programmer factory default address is 255 Mounting Pull down the handle so that the station is open Mount the station to a surface mounted box with the 2 screws Refer to Figure 3 Close the station Follow the instructions under the manual station on this page STATION GANG BOX 3 Mounting the manual station the manual station in of fire the alarm down the handle handle is now hanging down A qualified person must the station See Resetting the manual station 4 Resetting the manual station LT 6660 Rev 3 July 2020

Related Files