Mircom LT-6661 MS-700MP(U) Series Installation Manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | mircom-lt-6661-ms-700mp-u-series-installation-manual-8479152360.pdf |
---|---|
Type | |
Size | 901.35 KB |
Downloads |
Text Preview
Mircom MS 700MP U Series Fire Alarm Manual Stations manual fire alarm activation These high quality die cast stations are available as single or dual action devices They reset with a key Each station has a permanently attached MP Protocol addressable module which is configured with a see LT 6146 MIX 4090 Device Programmer for instructions Dimensions with Mircom Fire Alarm Control Panels Operating Voltage 15 30 VDC Rating Maximum alarm current 3.3 mA current 2 mA MS 702MP 4.93 H x 3.56 W x 2.56 D MS 710MP U 4.93 H x 3.56 W x 2.9 D Wire as shown so that supervision of connections is Maximum wire size 12 AWG ADA compliant To be installed per ADA 4.27.1 to 4.27.4 All manual fire alarm stations shall be installed as per the requirements outlined in the UL ULC codes as well all other applicable national or local codes Final is subject to the local authority having the manual station guide covers these models MS 702MP Intelligent Key Resettable Two Stage Manual MP MS 710MP U Intelligent Key Resettable Single Stage Dual Manual Station MP suffix U indicates a USA version of kit MS 702MP 4 mounting screws 2 reset keys black 2 stage keys 2 plastic rods MS 710MP U 4 mounting screws 2 reset keys black 2 rods Series Alarm Manual Station Wiring The maximum wire size is 12 AWG Connect the black wire from the previous station to terminal that is connected to the black wire from addressable module Connect the black wire leading the next station to the side of the terminal that is connected to the black wire from the addressable module The wires must be on opposite sides of the set screw to Figure 2 for the location of the wires Tighten the terminal Connect the red wire from the previous station to the that is connected to the red wire from the module Connect the red wire leading to the next station to the side of the terminal that is connected to the red from the addressable module The wires must be on opposite sides of the set screw to Figure 2 for the location of the wires Tighten the terminal NEXT STATION OR END LINE DEVICE 1 Wiring Diagram BOTH ON SIDES THE SET SCREW BOTH ON THE SIDE OF SET SCREW BLACK RED ADDRESSABLE ADDRESSABLE 2 Close up of terminals showing correct wiring Interchange Way ON L4K 5W3 1 888 647 2665 Witmer Industrial Estates Falls NY 14305 1 888 647 2665 LT 6661 Rev 1 July 2020 Setting the addressable module the instructions in LT 6146 MIX 4090 Device Programmer factory default address is 255 Mounting Open the station with the reset key Mount the station to a surface mounted box with 2 of the screws Refer to Figure 3 the plastic rod the station there is an opening below the white PULL This is where the plastic rod sits Pull down the PULL handle part way Carefully insert the plastic rod into the opening below the handle Move the PULL handle back to the upright position The handle should now be holding the plastic rod in Close and lock the station OF MANUAL STATION HOLE STATION GANG HOLE 3 Mounting the manual station Series Alarm Manual Station the manual station in of fire the alarm the MS 702MP pull down the PULL handle the MS 710MP U push in the PUSH bar then pull down PULL handle handle is now hanging down A qualified person must reset station by opening it with the reset key See Resetting the station below the stage two alarm MS 702MP only the stage two key into the keyhole above the PULL and then turn the key stage two alarm activates immediately stage two alarm will activate automatically a certain of time after the handle has been pulled if no is taken This time is set in the Fire Alarm Control the manual station use the reset key to open the station in order to reset it the station does not cancel the alarm at the Open the station with the reset key The switch is now reset you want to insert a plastic rod see Inserting the plastic above Move the PULL handle back to its upright position Close and lock the station Reset the Fire Alarm Control Panel to cancel the alarm Dual Action Manual Stations to Single MS 710MP U only Using a reset key unlock and open the manual station Remove the smaller two screws and accompanying brackets the PUSH bar Hold the manual station vertically with one hand with the at the bottom Tilt the manual station towards you remove the PUSH bar LT 6661 Rev 1 July 2020