Mircom LT-847 MGD-32 and AGD-048 Installation and Operation Manual (English)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | mircom-lt-847-mgd-32-and-agd-048-installation-and-operation-manual-english-6520143978.pdf |
---|---|
Type | |
Size | 3.96 MB |
Downloads |
Text Preview
MGD 32 and AGD 048 Multiplex Graphic Driver Annunciators and Adder Boards and Installation Manual Rev 9.1 2019 of Contents Features Instruction Instruction Models 5 Models 5 Specifications 5 Wiring 8 DC Power Wiring 8 Switch Settings Cabling for the AGD 048 Adder Annunciator 11 for the MGD 32 Master Graphic Driver Annunciator 11 Drivers And Adder Wiring For The MGD 32 Graphic Driver Annunciator 12 for the AGD 048 Adder Annunciator Board 18 Drain Calculations Current Draw 21 A Layout for Connectors on MGD 32 and AGD 048 22 and Warning Information modularly designed Remote Multiplex Graphic Driver Annunciators provide a large of annunciation up to 224 points with FA 200 FA 300 SFC 200 MR 2300 FR 320 FX 350 MR 2350 SFC 500 FX 3500 MR 3500 FA 1000 SFC 300 FX 2000 and MMX Series Fire Alarm Control Panels The MGD 32 Main Annunciator is a 32 Circuit Annunciator which may be expanded with up to four AGD 048 Adder Chassis to a maximum of 224 Circuit Display Points The MGD 32 has no button LEDs on the board Each Circuit Output will drive off board Indicators such as LEDs or on a GRAPHIC DISPLAY to form a graphic annunciator The drivers may be mounted using the metal plate included in the package to any of the approved backboxes or within graphic display It is intended that the MGD 32 and the AGD 048 are combined with a DISPLAY to make a graphic annunciator These graphic drivers have individual supervision circuitry which helps to identify burned out lamps Features Enclosure Models Steel enclosure finish painted semi gloss off white Material BB 5008 16 GA 0.060 thick CRS GA 0.060 thick CRS are available in 14 GA 0.075 thick CRS painted or Anodized Aluminum Enclosure Dimensions BB 5008 30 w x 36 H x 7 D 30 w x 60 H x 7 D Module Models MGD 32 Annunciator Chassis 32 Display Points DC nominal range 20 to 39 V DC filtered or full wave rectified for Indicators Lamp Fail Common Trouble Remote Failure A C General Acknowledge and Signal Silence and Controls System Reset Lamp Test Fire Aux Disconnect General Alarm Buzzer Silence Acknowledge and Signal Local Buzzer of up to 32 Points by using up to four AGD 048 Adder Modules 35 mA Alarm 1.6A Max AGD 048 Graphic Annunciator Chassis 48 Display Points DC nominal range 20 to 39 V DC filtered or full wave rectified of up to 48 Points to four AGD 048 Adder Modules may be driven from one MGD 32 25 mA Alarm 2.4A Max Environmental Specifications annunciator is intended for indoor use only Instruction Figure 1 Figure 2 and Figure 3 below the MGD 32 and AGD 048 may be mounted into BB 5008 and BB 5014 The MGD 32 and the AGD 048 are packaged with a metal plate and are mounted into the backbox View to mount Annunciator 6 display positions Dimensions x 22 W to mount a Driver to mount any metal plate for x HD 050 for x HD 050 1 Sample Layout in BB 5008 View 2 of brackets in BB 5008 Instruction View x HD 050 x HD 050 3 of Modules in BB 5008 Wiring Instruction RS 485 Wiring VDC VDC RS 485 Wiring to MGD 32 Driver needs to be Shielded Pair shown in the The wire may be AWG up to ft AWG up to ft RS 485 wiring the Fire Alarm Panel to the must point to point from FA Panel to the Annunciator then next Annunciator so on No star or T tapping allowed FROM FIRE ALARM OR PREVIOUS TWISTED SHIELDED PAIR TO NEXT ANNUNCIATOR SHIELDED PAIR VDC POWER FROM FIRE ALARM CONTROL PANEL PREVIOUS ANNUNCIATOR ONE PAIR VDC POWER TO NEXT ONE PAIR All circuits are power limited and use type FPL FPLR or FPLP power cable 4 RS 485 and 24V DC Power Wiring DC Power Wiring MGD 32 Annunciator Driver module has a 120 ohm End of Line Resistor on its RS 485 terminals This is removed on all except the last wired Module 24 V DC field wiring needs to be of an appropriate gauge for the number of annunciators the total wiring run length Refer to section 7.0 on page 21 to calculate the maximum for all annunciators summed together then use chart below to calculate size of wire for length of wire run Instruction Loop 1 Annunciator 24V DC Power Wiring Table Maximum Current all Annunciators Accidentally connecting any of the 24 VDC wires to the RS 485 wiring will in damage to the annunciator and or to the fire alarm control panel to it is connected Switch Settings Cabling Master Graphic Driver MGD 32 needs to be assigned a unique sequential Address via Main Chassis DIP Switch SW1 The AGD 048 does not require addressing Annunciator address refer to the manual for the specific fire alarm control panel being is set according to the table below 2 MGD 32 Annunciator Addresses Switch A0 A1 A2 A3 Address when used with FX 2000 version 2 X X or higher FX 350 MR 2350 MR 3500 FleX Net MMX and SFC 500 16 bit checksum when used with FX 2000 FA 1000 FA 300 MR 2300 FR 320 FA 200 and SFC 200 8 bit checksum Annunciators on a common RS 485 connection must be numbered sequentially 1 2 3 4 and not randomly such as 5 3 2 1 all Annunciator addresses are valid for all fire alarm control panels Address all switches off is not allowed and will generate an annunciator remote trouble Refer to the Fire Alarm Control Panel Manual for further information Switch Settings Cabling BOARD Cabling for the AGD 048 Annunciator Connects to the MGD 32 Main Chassis or to the AGD 048 Adder Chassis The AGD 048 its power from the Master Driver Connects to the next AGD 048 Annunciator Chassis Terminals L1 to L48 are zones Cabling for the MGD 32 Graphic Driver Co