Mircom LT-894MP - FleX-Net FX-4000N Manual

File Preview
File Preview
Click below to download for free

File Data

Name mircom-lt-894mp-flex-net-fx-4000n-manual-2836095714.pdf
Type PDF
Size 4.89 MB
Downloads

Text Preview

FX 4000 Intelligent Fire Detection and Voice Evacuation System and Operation Manual Rev 1 2021 of Contents Installation and Dimensions and Adder Modules Mounting Locations Components Settings Wiring Checkout Controls and Operation FleX Net System Layouts with Audio Components for the Integrated Fire Audio Cabinet Mass Notification System BBX FXMNS Enclosure Installation for the QBB 5001 R Expansion Audio Cabinet Audio Module Placement and Internal Wiring Fire Alarm Connection Expansion Audio Cabinet Module Placement and Removing Amplifiers QBB 5001 R Cabinet Connections Network Card and Telephone Network Card Amplifier Wiring Displays Controls Amplifier Installation Configuration ANC 4000 Audio Network Controller Module Wiring Vertical Paging Control Module Network Master Paging Control Module Network Paging Wiring and QAZT 5302DS Zoned Paging Selector Panels Operation Telephone Network Controller Module Vertical Master Telephone Master Firefighters Telephone Connections and QAZT 5302DS Firefighters Telephone Selector Panel Operation A Specifications B Power Supply and Battery Calculations C DIP Switch Settings D Alarm Verification Timing E Wiring For Addressable Supervised Output Module F Power Supply Batteries for Audio G FXMNS Used as a Mass Notification System ACU H APB 200 COA Sounder Bases I Label Requirements for Zone Identification and Warning Information the FleX Net FX 4000 Intelligent Fire Detection and Voice System FleX Net FX 4000 Intelligent Fire Detection and Voice Evacuation System offers components for network systems providing a wide variety of applications Designed peer to peer network communications using industrial standard ARCnet protocol FleX allows for a maximum of 63 nodes a node can be a control center or a floor panel while reliability and flexibility base panel consists of one intelligent analog loop or signalling line circuit SLC capable supporting 240 MGC MIX 4000 Series addressable devices The base panel also consists 4 Class A or B Indicating Circuits or notification appliance circuit NACs rated at 1.7 each A large 4 x 20 back lit alphanumeric 8 line LCD display and a 24 line graphical are available Additional SLC loops are available with MGC Protocol Quad Loop Adder ALCN 960MISO for expanding addressable loops SLC by 2 together with daughter ALCN 960D expanding addressable loops by a total of 4 Also available is the Quad Adder module ALCN 4792MISO for expanding addressable loops SLC by 2 with board ALCN 792D expanding addressable loops by a total of 4 configuration allows the FleX Net Fire Alarm Control Panels to be connected to a network which provides additional input circuits visual zones programmable appliance circuits and relays In addition a FleX Net Integrated Fire and Audio can be used to provide a fully distributed audio and or integrated telephone system FleX Net FX 4000 provides zoned emergency multi channel audio providing paging and fire evacuation and an optional firefighters telephone communication and from CACF Central Alarm and Control Facilities location to all remote telephone The system consists of an Integrated Fire and Audio Network Panel or FX MNS Each Integrated Fire and Audio Network Panel or FX MNS contains an audio portion consists of a QMB 5000N motherboard and card cage which holds an ANC 4000 Audio Card a TNC 5000 Telephone Network Card and up to 4 amplifiers a fire alarm FX 4000MNS Main Chassis a PS 2040 power supply and batteries The QBB expansion audio cabinet connected to a Integrated Fire and Audio Network Panel or node contains a card cage motherboard which holds up to 7 amplifiers has an audio supply battery charger and batteries all housed in an audio backbox enclosure communication and annunciation there is a microphone for paging a paging selector a firefighters telephone and associated selector panels The master paging and modules are intended for installation in a CACF Note that the paging microphone firefighters telephone may be used together or independently connected to a FleX Net Central Alarm and Control Facility CACF Features System Capacity and Modular Design peer to peer network communications up to 63 nodes including lobby panel copper and or fiber optic network cable a request grant or deny system with all controls disabled on node ancillary displays only as per ULC 527 11 a degraded mode of operation more than one operating node and a mode of operation only one operating node as per ULC 527 11 MGC Protocol Quad Loop Adder module ALCN 960MISO for expanding addressable SLC by 2 with daughter board ALCN 960D expanding addressable loops by a of 4 Each SLC Loop is set to function with MGC MIX 4000 Series addressable 240 sensors and modules and can be wired as Class A Class X or Class B Protocol Quad Loop Adder module ALCN 4792MISO for expanding addressable SLC by 2 with daughter board ALCN 792D expanding addressable loops by a of 4 Ampere Power Supply Class A or B NACs rated at 1.7 Amperes each which can be configured as Audible Visual silenceable or non silenceable circuits Audibles may be steady Temporal California Code or March Time circuits NACs may be configured to provide additional auxiliary power or auxiliary power NAC expansion using the INX 10A INX 10ADS or INX 10AC isolators are present on all in panel addressable loops Signal Silence Inhibit Auto Signal Silence Two Stage Operation Assisted Test Outputs for 4 Wire resettable Smoke Power Supply Auxiliary Power Supply and an to the Mircom RTI 1 Remote Trouble Indicator Interface for Remote Annunciators Remote Annunciators do not occupy a node the network Up to seven annunciators can be connected per node Level Password Protection with field settable definition which enables the installer determine what functions are accessible for each level of password queues for acknowledge with Alarm Queue Supervisory Queue Trouble Queue BLDG Monitor Queue LED indicators and pushbuttons Form C Relay Contacts for Common Alarm Common Supervisory and Trouble Port for remote system printer or terminal Event History Logs one for Alarm related events and one for all events Controls and Indicators for System Reset Lamp Test Visual Indicator Test Drill Signal Silence General Alarm General Alarm Cancel Automatic Alm Sig AC On CPU Fault and Ground Fault Spare configurable switches and LED Indicators Zone configurable LED bi coloured Annunciator with slide in labels for Zone with the DSPL 420 16TZDS Display drift compensation for ionization and photoelectric smoke detectors Signal Coding of signal circuits for easy alarm identification code consists of 1 4 digits each digit consisting of 1 15 pulses on the signal for Canadian ULC or USA ULI requirements for Smoke Sensor sensitivity transient protection Mountable Enclosures with removable doors for easy installation and service trims available Terminal Blocks for easy wiring and service OPEN Graphic Navigator Software Package allows 3D graphic display of premises

Related Files