FA 300 Series Fire Alarm Control Panel Life Safety Solutions Normal WED 2003 10 01 ON ALARM CPU FAIL SERIES Alarm Control Panel and Operation Manual Rev 1 2017 of Contents this Manual 5 Support 5 Display Buzzer and LED Indicators 7 On LED 7 LED 7 LED 7 LED 7 Fail LED 7 Display Buttons RESET 8 SILENCE 8 DRILL 8 TEST 8 SILENCE 8 Up and Down Arrow Buttons 8 9 MENU and CANCEL 9 and Reconnecting a Circuit Zone Disconnect Bypass a Circuit 10 Reconnect Unbypass a Circuit 11 On screen Messages 1 detection circuit 12 2 indicating circuit 12 Messages 13 Power Fail 13 Trouble 13 Fault 14 num mismatch 14 Pwr Supply 15 Aux supply 15 tie Polarity reversal PR 300 Relay module 16 20 of Figures 1 Main Display 6 2 LED Indicators 7 3 Verified Alarm Example 12 4 Silenceable Signal Example 13 5 AC Power Fail 13 6 Battery Trouble 14 7 Ground Fault 14 8 RAU num mismatch 15 9 4Wire Pwr Supply 15 10 Aux Power Supply 16 11 CtyTie RM312 missing 16 12 City Tie trouble 17 20 About this Manual user guide provides information on the main indicators and controls of the FA 300 Fire Control Panel Specifically with this manual you will learn about What the LEDs on the main display indicate What the buttons on the main display do What certain common LCD screen messages mean to the Glossary on page 18 for an explanation of terms used in this manual Technical Support all technical support inquiries please contact Mircom Technical Support Department 8 A M and 5 P M EDT Monday through Friday excluding holidays Phone 905 695 3535 Phone 1 888 449 3535 Fax 905 660 4113 Fax 1 888 660 4113 techsupport mircom com 20 Main Display 1 shows the LCD display LED indicators and control buttons locations Normal MON 2003 04 05 ON FAIL 1 Main Display main display panel on the fire alarm control board consists of LED indicators located just below the LCD screen buttons left edge of display program buttons right part of display indicators may be amber red or green and may illuminate continuously steady or at of two flash rates flash supervisory 120 flashes per minute flash 20 flashes per minutes 20 Buzzer and LED Indicators ON FAIL 2 Indicators Buzzer A C On LED Alarm LED Supervisory LED Trouble LED CPU Fail LED buzzer sounds if there is a fire alarm a supervisory alarm or a trouble in the fire alarm It turns off if the condition causing the buzzer to sound is cleared or if the BUZZER button is pressed green A C On LED illuminates steadily as long as the main power is above minimum The indicator turns off when the level falls below the minimum level and the panel to standby battery power red Alarm LED illuminates steadily when there is a fire alarm This indicator will remain on the system is reset amber Supervisory LED illuminates at the fast flash rate when there is a supervisory in the fire alarm system For non latching supervisory alarms the SUPV LED will turn off the condition causing the alarm goes away For latching supervisory alarms this LED on until the panel is reset Trouble LED flashes amber at the trouble flash rate when the panel detects any trouble For non latching trouble conditions the Trouble LED turns off when the condition the alarm goes away For latching trouble conditions the LED remains on until the is reset CPU Fail LED flashes amber at the trouble flash rate to indicate a microprocessor failure the main board 20 Main Display Buttons SYSTEM RESET SYSTEM RESET button resets the fire alarm control panel and all SIGNAL SILENCE

Related Files