Mircom MIX-2351APA Installation Manual - English

File Preview
File Preview
Click below to download for free

File Data

Name mircom-mix-2351apa-installation-manual-english-8410659723.pdf
Type PDF
Size 884.94 KB
Downloads

Text Preview

I Technologies Ltd Interchange Way Vaughan ON L4K 5W3 905 660 4655 FAX 905 660 4113 AND MAINTENANCE INSTRUCTIONS to 32 VDC uA one communication every 5 seconds with green LED blink on communication mA 24 VDC one communication every 5 seconds with red LED solid on mA 24 VDC one communication every 5 seconds with amber LED solid on to 93 Relative Humidity Non condensing to 122 0 to 50 to 4000 ft min 0 to 1219.2 m min 51 mm installed in B300A 6 Base 156 mm installed in B300A 6 Base 4.1 104 mm installed in B501 Base oz 95 g Protocol Photoelectric Smoke Sensors Voltage Range Current 24 VDC Alarm Current Current Humidity Range Temperature Range Velocity Load Rating refer to your isolator base module manual for isolator calculation instructions S529 listed for Open Air Protection sensor must be installed in compliance with the control panel system manual The installation must meet the requirements of the Au Having Jurisdiction AHJ Sensors offer maximum performance when in compliance with CAN ULC S524 DESCRIPTION is a plug in type smoke sensor that combines a photoelectronic chamber with addressable analog communications sensors transmit an analog representation of smoke density over a com line to a control panel Rotary dial switches are provided for set the sensor address See Figure 1 1 ROTARY ADDRESS SWITCHES GUIDE wiring must be installed in compliance with the Canadian Electrical Code local codes and any special requirements of the Authority Having Proper wire gauges should be used The installation wires should color coded to limit wiring mistakes and ease system troubleshooting Im connections will prevent a system from responding properly in the of a fire power from the communication line before installing sensors Wire the sensor base supplied separately as shown in the wiring See Figure 2 Set the desired address on the sensor address switches See Figure 1 Install the sensor into the sensor base Push the sensor into the base while it clockwise to secure it in place After all sensors have been installed apply power to the control panel and the communication line Test the sensor s as described in the TESTING section of this manual covers provide limited protection against airborne dust particles during Dust covers must be removed before the sensors can sense smoke sensors prior to heavy remodeling or construction 2 WIRING DIAGRAM Do not loop wire under 1 or 2 Break wire run to connections A OPTIONAL WIRING photoelectric smoke sensors include a tamper resistant capability prevents removal from the base without the use of a tool Refer to the manual for details on making use of this capability C0129 11 0 0 LEDs on the sensor are controlled by the panel to indicate sensor status output is provided for connection to an optional remote LED annunciator RA100ZA panels offer different features sets across different models As a result features of the photoelectric sensors may be available on some control but not on others MIX 2351APA supports Advanced Protocol and CLIP Loop Interface Protocol mode possible features available if supported by the control panel are The sensor LEDs can operate in three ways off and blinking can be set to red green or amber This is controlled by the panel The remote output may be synchronized to the LED operation or con independent of the LEDs Devices are point addressable up to 159 addresses refer to the operation manual for the ULC listed control panel for spe operation The photoelectric sensors require compatible addressable to function properly Connect these sensors to listed compat control panels only recommends spacing sensors in compliance with CAN ULC S524 In air flow applications with smooth ceilings space sensors 30 feet apart m For specific information regarding sensor spacing placement and applications refer to CAN ULC S524 or the System Smoke Detector Guide available from Mircom Intelligent photoelectric smoke sensors are also listed for use inside duct smoke detectors Applications MIX 2351APA is listed for use in ducts See Duct Smoke Applications Guide HVAG53 for details on pendant mount applications Intelligent photoelectric smoke sensors are also listed for use inside duct smoke detectors Vacuum the screen carefully without removing it If further cleaning is continue with Step 4 otherwise skip to Step 7 Remove the chamber cover screen assembly by pulling it straight out Use a vacuum cleaner or compressed air to remove dust and debris from sensing chamber Reinstall the chamber cover screen assembly by sliding the edge over the chamber Turn until it is firmly in place Replace the cover using the LEDs to align the cover and then gently push it until it locks into place Reinstall the detector Test the detector as described in TESTING Reconnect disabled circuits Notify the proper authorities that the system is back on line NOTE REGARDING SMOKE DETECTOR GUARDS detectors are not to be used with detector guards unless the combina has been evaluated and found suitable for that purpose 3 FEATURES OF THE PHOTO DETECTOR Alignment Notch 4 CLEANING THE PHOTO DETECTOR Test Marker C2021 00 Cover Chamber and Screen Chamber C2022 00 testing notify the proper authorities that the system is undergoing and will temporarily be out of service Disable the system to unwanted alarms sensors must be tested after installation and periodically thereafter Test methods must satisfy the Authority Having Jurisdiction AHJ Sensors maximum performance when tested and maintained in compliance with S536 sensor can be tested in the following ways Functional Magnet Test P N M02 04 01 or M02 09 00 Hold the test magnet in the magnet test area as shown in Figure 3 This sensor can be functionally tested with a test magnet The test magnet simulates smoke in the sensing chamber testing the sensor and connections to the control panel The sensor should alarm the panel Two LEDs on the sensor are controlled by the panel to indicate sensor Coded signals transmitted from the panel can cause the LEDs to latch on or latch off Refer to the control panel technical documen for sensor LED status operation and expected delay to alarm Smoke Entry Sensitivity readings are available through the FACP Refer to the manufac published instructions for proper use Additionally canned aerosol simulated smoke canned smoke agent may used for smoke entry testing of the smoke detector Tested and ap aerosol smoke products include Fire and Safety Climb 30S PURCHECK CENTURIAN SOLOA4 TRUTEST 2000 When used properly the canned smoke agent will cause the smoke detec to go into alarm Refer to the manufacturer published instructions for use of the canned smoke agent aerosol simulated smoke canned smoke agent formulas will vary manufacturer Misuse or overuse of these products may have long term effects on the smoke detector Consult the canned smoke agent manu published instructions for any further warnings or caution statements sensor that fails any of these tests may need to be cleaned as described CLEANING and retested testing is complete restore the system to normal operation and notify proper authorities that the system is back in operation removing the detector notify the proper authorities that the smoke system is undergoing maintenance and will be temporarily out of Disable the zone or system undergoi

Related Files