Mircom MIX-4003-S Sounder Base Installation Manual

File Preview
File Preview
Click below to download for free

File Data

Name mircom-mix-4003-s-sounder-base-installation-manual-2056814937.pdf
Type PDF
Size 1.85 MB
Downloads

Text Preview

Interchange way Vaughan Ontario L4K 5W3 905.660.4655 Fax 905.660.4113 www mircom com ATTENTION NOT PAINT OR ALTER APPLIED FINISH IN ANY WAY PAS PEINDRE OU MODIFIER FINITION ORIGINALE 1 MODEL FRONT AND SIDE VIEW MIX 4000 SERIES DETECTOR 1 SPECIFICATION temperature range voltage Standby Current Alarm Current Diameter Height wire gauge to 49 to 120 to 93 24VDC VFWR mA 7 3 16 in 1 1 4 in AWG AND MAINTENACE INSTRUCTIONS Sounder Base THIS MANUAL manual is included as a quick reference for installation should be left with the owner operator of this For further information on the use of this with a FACP please refer to the panel manual This manual should be left with the owner operator this equipment BASE DESCRIPTION MIX 4003 S sounder base horn is designed to meet S529 requirements for smoke detector S530 requirements for heat detector and S525 requirements for audible notification MGC MIX 4003 S is providing localized alarm sounding for the MIX 4000 family of fire detection devices can be used in place of external sounders to minimize cost and footprint while allowing individual of signal rate and on off state for each device The must be used with a compatible MGC control Operational mode and levels are selected at the Fire panel through the MGC MP configuration tool MIX 4003 S produces an alarm signal at SPL of Table 2 Rev 1.1 November 10 2021 COMPONENT 2 SOUNDER BASE ASSEMBLY COMPONENTS 4 WIRING TABS plate x 3 4 x2 base x25 mm x2 3 MIX 4000 SEREIS DETECTOR series mounting plate in figure 2 is mounted first on the box and all wiring is done on integral screw The connections are apparent and can be inspected before the sounder base itself is Then the enclosure containing the electronics sounder and the detector base can plugged in and This device should be installed as per applicable of the authorities having jurisdiction installing this device seek guidance from the control panel instructions for the device modes and the configuration requirements It is to remove power from SLC and NAC lines performing installation the information in this document to determine the current draw of the devices The total current draw of devices must not exceed the NAC output capacity of panel In all cases the installer should consider the drop to ensure that the last device on the circuit within its rated voltage Please consult fire panel manual for guidance on wire resistance and For maximum strobe operating current please to Table 4 not loop signal circuit field wires around terminals supervision requires wire run to be broken at end Wire run is broken Wrong Wire is looped 5 DEVICE CONNECTION Wiring must be in accordance with CSA C22.1 Electrical Code Part I Safety Standard for Installations section 32 and or NFPA 70 SYSTEM SUPERVISION FOR ALL TERMINAL TAPS DO USE LOOPED WIRE UNDER TERMINALS BREAK WIRE TO PROVIDE SUPERVISION OF CONNECTIONS PAS UTILISER DE FILS EN BOUCLE SOUS LES BORNES FOURNIR UN BON SUIVI DES CONNEXIONS LA CONTIUIT DES C recommends spacing speaker strobe appliances in with CAN ULC S524 and or NFPA72 mounting plate is compatible with 3 by 2 single gang boxes 3 3 4 by 4 double gang boxes 4 by 2 gang utility boxes standard 4 by 4 boxes and 4 octagon boxes Attach the mounting plate to electrical box with two mounting 8 32 x 3 4 screws Slide down the sounder base enclosure until the blades touch the clips on the mounting plate Secure the mounting plate with securing M3 x25 mm 6 MOUTING DIAGRAM 1 2 3 DETECTOR the detector type and address has be visible from the break the address tab inside the detector base insert it in the outer rim of the base See figures 7 9 DETECTOR ALIGNMENT MARK 7 ADDRESS TAB INSERT tab detector can then be placed on the top base using the steps figure 8 Position the detector centrally on its adapter base it is level Rotate clockwise applying gentle pressure The detector drop into its keyed location Continue to rotate clockwise a few degrees until the has fully engaged in the adapter base When the detector is firmly engaged check the of the raised reference marks on the detector on the base figure 9 8 MOUNTING DETECTOR clockwise lock counter unlock RATINGS 2 SOUND PRESSURE LEVEL OUTPUT Reverberant dBA 10ft VDC VDC VDC VFWR VFWR VFWR VDC VDC VDC VFWR VFWR VFWR Anechoic dBA 3m BPM BPM 3 DIRECTIONAL SOUND CHARACTERISTICS 34 41 90 36 42 90 dBA in horizontal in vertical RMS CURRENTS 4 OPERATING RMS CURRENTS mA BPM sounder base is capable of producing a variety of tone patterns including the distinctive three pulse temporal ANSI Temporal 3 fire alarm signal now required by NFPA 72 for commercial and residential applications and is in this default mode The device offers two volume levels low and high The available tones are Continuous Temporal 3 20 BPM and March Refer to the appropriate fire alarm control panel manual for more information on of these tones NOTE For NFPA 72 Installations the Temporal 3 tone at high volume should be used for and public mode evacuation The use of other tone styles and low volume level will be at the discretion of local Authority Having Jurisdiction AHJ photoelectric detector photoelectric detector Rev7 Numbers 4000 SERIES SOUNDER BASE SERIES DETECTORS Isolated photoelectric detector Isolated photoelectric detector Rev7 Non isolated photoelectric heat detector Non isolated photoelectric heat detector Rev7 Isolated photoelectric heat detector Isolated photoelectric heat detector Rev7 Isolated heat detector heat detector shorting clip

Related Files