Mircom MIX-4040 Dual Input Module Installation Manual

File Preview
File Preview
Click below to download for free

File Data

Name mircom-mix-4040-dual-input-module-installation-manual-7415962803.pdf
Type PDF
Size 1.36 MB
Downloads

Text Preview

INSTALLATION AND MAINTENANCE INSTRUCTIONS DUAL INPUT MODULE Interchange way Vaughan Ontario L4K 5W3 905.660.4655 Fax 905.660.4113 www mircom com You must disconnect power from the system before installing module If this unit is being installed in a system that is currently it is necessary to inform the operator and the local that the system will be temporarily out of service MIX 4040 module is intended to be mounted in a standard 4 back box see Figure 2 The box must have a minimium of 2 1 8 inches Surface mounted electrical boxes BB 400 available from Mircom 2 MODULE MOUNTING THIS MANUAL manual is included as a quick reference for installation For fur information on the use of this device with a FACP please refer to panel manual This manual should be left with the owner operator of this DESCRIPTION MIX 4040 Dual Input module is designed to operate with a listed intelligent fire system control panel The module can sup one Class A or 2 Class B inputs When configured for Class A the module provides an internal EOL resistor When con for Class B operation the module can monitor two indepen input circuits while using only one module address The of each module is set using the MIX 4090 programmer tool up to 240 units may be installed on a single loop The module a panel controlled LED indicator 1 MODULE FRONT to 30VDC with two 22k EOL Ohms Operating Voltage Current Current Resistance Input Wiring Resistance 150 Ohms total Range to 120F 0c to 49C to 93 Non condensing 5 8 x 4 1 4 W x 1 1 8 D square by 2 1 8 deep box Programmer Electrical Box EOL on mounting plate to 12 AWG range on all terminals This device should be installed as per applicable requirements the authorities having jurisdiction This device shall be connected power limited circuits only Install the module wiring as indicated by the job drawings and wiring diagrams see Figure 3 for an example of wring for Class A connected device and Figure 4 for an example of Class B Use the programmer tool to set the address on the module as on the job drawings Mount the module in the electrical box as shown in figure 2 LT RESISTOR THE MODULE 22k 22k 3 SAMPLE CLASS A WIRING PANEL OR DEVICE PANEL OR DEVICE 4 SAMPLE CLASS B WIRING PANEL OR DEVICE PANEL OR DEVICE LT

Related Files