Mircom MIX-4042 Conventional Zone Module Data Sheet - English
File Preview
Click below to download for free
Click below to download for free
File Data
Name | mircom-mix-4042-conventional-zone-module-data-sheet-english-3409217586.pdf |
---|---|
Type | |
Size | 1.19 MB |
Downloads |
Text Preview
CONVENTIONAL ZONE MODULE Any combination of MIX 4000 series devices up to 240 be connected on a single SLC Mounts in a standard 4 square or double gang electrical box Indicating LED provides module status Compatible with conventional two wire or 4 20mA devices Can be configured for one 1 Class A or one 1 Class B with conventional devices A single stocked device type covers two applications Compatible with a large array of two wire devices See document LT 1023 Conventional Zone Input Module 4 20mA two wire devices MIX 4042 Analog interface module is designed to be with an MGC compatible control panel providing high of information exchange and fast and secure responses MIX 4042 Conventional Zone Module allows a zone conventional two wire detectors to be interfaced to an loop It can also be configured to work with 4 20mA external listed power supply can be connected to several 4042 modules to provide power to the devices while electrically isolated from the FACP MIX 4042 monitors the current used by the devices and alarms and troubles accordingly configured for conventional devices the module will handle Class A or Class B lines MIX 4042 has an internal EOL resistor for Class A lines MP 300 end of line resistor must be used for Class B address of each module is set using the MIX 4090 tool module has a panel controlled LED indicator The LED during normal operation and stays ON steadily when device is in alarm condition MIX 4042 supports 2 wire smoke detectors on a Class loop or alternatively the MIX 4042 can be configured to 4 20mA devices Trouble and monitor event current can be set at configuration time Due to UL listing alarm compatibility with 4 20mA devices will be on demand TO BE USED FOR INSTALLATION PURPOSES INFORMATION IS FOR MARKETING PURPOSES ONLY AND INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY NUMBER Specifications Specs Operating Value Current Current Specs Resistance Conventional Zone Wiring Resistance 4 20mA Wiring Resistance Conventional Zone Power Supply Supply Current Current Conventional Only Devices Current Short Circuit Current Range Range on all terminals to 30 VDC Ohms Ohms Ohms nominal 18 to 30 V maximum at 30 VDC E O L only maximum total or less on devices line to 120 0 to 49 to 93 Non condensing to 12 AWG x 4.25 W x 1.125 D mounted on a standard 4 square box Also compatible with electrical boxes or Mircom BB 400 surface mount box See Mircom document LT 1023 for compatible two wire devices Information Zone Module Addressable Device Programmer on mounting plate Mount Electrical Box Interchange Way Ontario L4K 5W3 905 660 4655 905 660 4113 Witmer Industrial Estates Falls NY 14305 Free 888 660 4655 Toll Free 888 660 4113 INFORMATION IS FOR MARKETING PURPOSES AND NOT TO DESCRIBE THE TECHNICALLY complete and accurate installation testing and certification refer to technical This document contains intellectual property of Mircom information is subject to change by Mircom without notice does not represent or warrant correctness or completeness relating 9510 3