Mircom MIX-4045 Dual Relay Module Data Sheet - English

File Preview
File Preview
Click below to download for free

File Data

Name mircom-mix-4045-dual-relay-module-data-sheet-english-7164539028.pdf
Type PDF
Size 1.15 MB
Downloads

Text Preview

DUAL RELAY MODULE Any combination of MIX 4000 series devices up to 240 be connected on a single SLC Mounts in a standard 4 square or double gang electrical box Indicating LED provides module status Two individually controllable contacts per module Each contact provide access to normally closed and open sides Contact position is verified by the module Stuck or contacts are reported as a trouble The SLC and externally powered connections are on sides of the device for easy installation no need install an additional barrier Supports group activation capability for fast reaction time Provides two 2 outputs using only one 1 module to 30 VDC Specifications Operating Value Alarm Current 3.1 mA Current mA to 120 0 to 49 Range to 93 Non condensing Range to 12 AWG all terminals H x 4.25 W x 1.125 D mounted on a standard square box INFORMATION IS FOR MARKETING PURPOSES ONLY AND INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY complete and accurate technical information relating to performance testing and certification refer to technical literature This document intellectual property of Mircom The information is subject to change Mircom without notice Mircom does not represent or warrant correctness completeness NUMBER 9508 2 MIX 4045 Dual Relay Module is an intelligent addressable designed to be used with an MGC compatible control providing high rates of information exchange and fast secure responses MIX 4045 Dual Relay Module controls two independent while using only one module address module provides two form C SPDT contacts rated at 30VDC or 0.5A at 125VAC and the Fire panel can each contact individually are electrically isolated from the Fire alarm panel at times Refer to MIX 4046 if a supervised output is required contact position is verified by the module at all times If a is not at the required position during standby or active a trouble will be reported by the panel address of each module is set using the MIX 4090 tool module has a panel controlled LED indicator The LED during normal operation and stays ON steadily when device is in alarm condition Information Relay Module Addressable Device Programmer Mount Electrical Box Interchange Way Vaughan ON L4K 5W3 905 660 4655 Fax 905 660 4113 Witmer Industrial Estates Niagara Falls NY 14305 Free 888 660 4655 Fax Toll Free 888 660 4113

Related Files