Mircom MIX-FC351AP(A) Advanced Multi-Criteria Fire Co Detector Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

ADVANCED MULTI CRITERIA FIRE CO DETECTOR Unique ability to detect all four major elements of a fire Separate CO detection signal Highest nuisance alarm immunity Automatic drift compensation of smoke sensor and CO cell RealTest CO testing capability UL 268 7th edition UL 521 and UL 2075 listed Separates audible signal for fire or CO alarm when used the APB200 bases year CO cell with end of life warning and fault Compatible with Mircom Intelligent control panels in AP mode such as FlexNet Series CLIP mode not supported APB200 WH APB200 LF WH recognize the protocol This enables it to be used as a of the general evacuation signal along with other horn strobes and chimes when connected to a power or Fire Alarm Control Panel FACP output capable generating the synchronization pulses With each sounder carrying a unique address the FACP can then command indvidual sounder or a group of sounders to activate The set from the panel can be tailored to the specific allowing selection of volume tone and group Advanced Protocol AP devices use a high speed protocol that greatly increases the speed of between the intelligent devices Mircom Protocol uses a superior group polling method as as an interrupt feature that provide for a faster response to alarm condition In addition the Advanced Protocol allows greater system capacity with support for up to 159 sensors 159 modules totaling to 318 devices per SLC circuit NUMBER Multi Criteria Fire CO Detector installed APB200 WH sounder base MIX FC351AP is an intelligent multi criteria detector photoelectric thermal infrared and Carbon CO detection principles that provide both fire and detection For fire sophisticated algorithms maximize the of all four sensor types creating our best detection offering heightened immunity to nuisance particulate enhanced sensitivity to real fire sensors and communication can greatly reduce alarms compared to single sensing methods ability to reject certain nuisance alarm triggers such as smoke supports the use of the fire CO detector in where moderate to heavy nuisance conditions that might cause single sensing detectors to false alarm through the incomplete burning of various fuels is a colorless odorless and deadly gas that is virtually to detect with the human senses Because the exists for dangerous levels of CO to accumulate almost any building legislation mandating the use of CO in commercial spaces continues to increase across U S and Canada The MIX FC351AP meets both UL 268 edition and UL 521 listing requirements for fire detection as as the UL 2075 standard for system connected life safety monoxide detection MIX FC351AP is recommended for use in conjunction the APB200 WH or APB200 LF WH intelligent sounder which can generate either a Temp 3 pattern for fire or a 4 pattern for CO alarm indication The APB200 LF WH frequency sounder base is designed to meet the NFPA sleeping space requirement to produce a fundamental of 520 Hz 10 with a square wave or its TO BE USED FOR INSTALLATION PURPOSES INFORMATION IS FOR MARKETING PURPOSES ONLY AND INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY to 32 VDC at 24 VDC one communication every 5 seconds with LED blink enabled 69mm installed in APB200 WH style base installed in APB200 WH style base 95gm to 90 relative humidity non condensing to 100 0 to 38 to 4000 ft min 0 to 20 m sec Specifications Weight Humidity Range Temperature Range Velocity Specifications Voltage Range Standby Current Alarm Current LED on 4.5 mA at 24 VDC Settings and Suggested Applications 1 2 3 1 2 3 1 2 1 Setting of smoke of smoke Application clean environments laboratories environments offices of smoke No Delay Moderately clean environments hotel rooms dorm rooms near a shower boiler rooms 4 2 4 of smoke Maximum 10 minutes delay from photo output 5 3 of smoke Alarm Heat Only at 135 57 or rate of rise limits 5 6 the CO cell has reached end of life the CO sensor no longer provides life safety protection however when the fire enters Photo Thermal Infrared PTIR mode the following sensitivities apply 1 2 4 clean environments laboratories environments offices rooms near a shower boiler rooms rooms kitchens paint shops of smoke of smoke 1 2 4 1 2 2 of smoke Maximum 10 minutes delay from photo output 6 Monitoring UL Standard Reference Alarm Thresholds are as Follows Alarm Heat Only at 135 57 or rate of rise limit Per Million Response Time 5ppm 5ppm 10ppm 240 min 50 min 15 min UL standard 2075 the MIX FC351AP has been tested to the sensitivity limits defined in UL standard 2034 TO BE USED FOR INSTALLATION PURPOSES INFORMATION IS FOR MARKETING PURPOSES ONLY AND INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY 5901 2 of 3 Multi Criteria Fire CO Detector UL Multi Criteria Fire CO Detector ULC Base White UL ULC Base Ivory UL ULC Base White UL ULC Base Ivory UL ULC Sounder Base White UL Sounder Base Ivory UL Sounder Base White ULC Sounder Base Ivory ULC low frequency sounder base White UL low frequency sounder base Ivory UL Sounder Base Includes CO detector markings in English and French White ULC Sounder Base Includes CO detector markings in English and French Ivory ULC Information MIX FC351AP A detectors are also backward compatible with the bases APB200 APB200COA and APB200 LF for applications with Mircom Intelligent control panels operating in AP mode such as FlexNet Series CLIP mode is not supported specifications subject to change without notice Ring White Ring Ivory Kit with IR opening White Includes cover and Trim ring Kit with IR opening Ivory Includes cover and Trim ring Kit with IR opening Black Includes cover and Trim ring Interchange Way Ontario L4K 5W3 905 660 4655 905 660 4113 Witmer Industrial Estates Falls NY 14305 Free 888 660 4655 Toll Free 888 660 4113 INFORMATION IS FOR MARKETING PURPOSES AND NOT TO DESCRIBE THE TECHNICALLY complete and accurate installation testing and certification refer to technical This document contains intellectual property of Mircom information is subject to change by Mircom without notice does not represent or warrant correctness or completeness relating 5901 0

Related Files