Notifier 5600 Series Mechanical Heat Detectors

File Preview
File Preview
Click below to download for free

File Data

Name notifier-5600-series-mechanical-heat-detectors-9756238041.pdf
Type PDF
Size 921.89 KB
Downloads

Text Preview

5600 Series Heat Detectors Sensor 5600 Series mechanical heat detectors offer protection against fire and for non life safety installa where smoke detectors are inappropriate configurations The 5600 Series offers a full line of to accommodate a broad range of applications single and dual circuit models are offered each avail for low and high temperature ratings with either fixed or combination activation The ROR element of the fixed ROR models restorable to accommodate field testing the unit flexibility To satisfy a variety of installations the Series easily mounts to single gang and octagonal back These models also accommodate 4 101.6 mm backboxes when used with a plaster ring The mount bracket is reversible to allow for flush and surface mount installations identification The 5600 Series provides clear mark on the exterior of the unit to ensure that the proper detec is being used Alphanumeric characters identify the method as well as the temperature rating in Fahrenheit and Celsius Fixed temperature models identified while combination fixed rate of rise units marked The 5600 Series also provides a col as a post activation indicator Once the detector has activated the collector drops from the unit to allow easy of the specific unit in alarm Multiple configurations available Fixed temperature non resettable or combination fixed self restoring Low temperature and high temperature ratings Single circuit and dual circuit Easy to read alphanumeric identification of detector type temperature rating External collector provides visual indication of activation Reversible mounting bracket for flush and surface mount I 304 Initiating Devices SPECIFICATIONS installation temperature models 5601P 5603 5621 5623 100 38 models 5602 5604 5622 5624 150 65.6 temperature models 5601P 5603 5621 5623 135 57 models 5602 5604 5622 5624 194 90 Threshold 15 8.3 per minute models 5602 5621 5622 only Humidity Range 5 to 95 RH noncondensing Terminals non polarized accept 14 to 22 AWG 2.0 to mm diameter with mounting bracket 4.57 116 mm with mounting bracket 1.69 43 mm 6 oz 170 grams Options 3.5 88.9 mm octagonal backbox 4 mm octagonal backbox single gang backbox 4 mm square backbox with a square to round plaster Flexible mounting capabilities single gang 3.5 or 4 octag 4 101.6 mm square with plaster ring SPECIFICATIONS Easy to use terminal screws provide a more positive wiring Voltage Ratings resistive Low profile design to coordinate with room aesthetics LISTINGS AND APPROVALS listings and approvals apply to the modules specified in document In some cases certain modules or applications not be listed by certain approval agencies or listing may in process Consult factory for latest listing status UL Listed S2101 ULC Listed S2101 all with suffix MEA 199 03 E CSFM 7270 1209 227 7270 1653 167 FM Approved 125 VAC 28 VDC VDC VDC A A A A heat detector shall be a System Sensor 5600 model number Listed to Underwriters Labora UL 521 for Heat Detectors for Fire Protective Signaling The detector shall be either a single circuit or a dual type normally open The detector shall be rated for acti at either 135 57 or 194 90 and shall acti by means of a fixed temperature thermal sensor or a sensor rate of rise element shall be activated by a rapid rise in approximately 15 8.3 per minute The shall include a reversible mounting bracket for mount 2 9 10 Page 1 of 2 to 3.5 inch 88.9 mm octagonal 4 inch 101.6 mm octag single gang and 4 inch 101.6 mm square backboxes a square to round plaster ring Wiring connections shall made by means of SEMS screws that shall accommodate 22 AWG wire The detector shall contain alphanumeric on the exterior of the housing to identify its tempera rating and activation method The rate of rise element of fixed temperature rate of rise models shall be to allow for field testing The detectors shall include external collector that shall drop upon activation to identify unit in alarm INFORMATION on Temperature 57 Fixed Temperature Rate of Rise 90 Fixed Temperature Rate of Rise 57 Fixed Temperature 90 Fixed Temperature 57 Fixed Temperature Rate of Rise 90 Fixed Temperature Rate of Rise 57 Fixed Temperature 90 Fixed Temperature Protected Spacing 3.048 m Ceiling ft x 50 ft 15.24 m x 15.24 m ft x 50 ft 15.24 m x 15.24 m ft x 25 ft 7.62 m x 7.62 m ft x 25 ft 7.62 m x 7.62 m ft x 50 ft 15.24 m x 15.24 m ft x 50 ft 15.24 m x 15.24 m ft x 25 ft 7.62 m x 7.62 m ft x 25 ft 7.62 m x 7.62 m Refer to NFPA 72 guidelines for spacing reductions when ceiling heights exceed 10 feet 3.048 m Add an to part number for ULC model DIAGRAMS Models Models by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Notifier Phone 203 484 7161 FAX 203 484 7118 in the U S A 2 of 2 DN 6931 A1 2 9 10

Related Files