Notifier AFP1010 with the DIA-1010 (A1ROM6 6N & AROM6 6N)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | notifier-afp1010-with-the-dia-1010-a1rom6-6n-arom6-6n-9072841563.pdf |
---|---|
Type | |
Size | 932.42 KB |
Downloads |
Text Preview
NOTIFIER Pittway Company Clintonville Road CT 06472 1610 FAX 203 484 7118 Release Summary the Notifier AFP1010 Security Control Panel with the Display Interface Assembly AROM6.6N document covers AFP1010 Release 6.6 Software as it affects the ROMs System Reacceptance Test after Software Changes To ensure proper operation this product must be tested in accordance with NFPA 72 1993 Chapter after any programming operation or change in site specific software Reacceptance is required after any change addition or deletion of system components or after modification repair or adjustment to system hardware or wiring components circuits system operations or software functions known to be affected a change must be 100 tested In addition to ensure that other operations are not affected at least 10 of initiating devices that are not directly affected by change up to a maximum of 50 devices must also be tested and proper system verified 50360 Revision 50360 B ECN 97 018 List following replacement ROMs must be ordered individually according to your system requirements AROM6.6Ns and A1ROM6.6Ns cannot be in conjunction with earlier ROMs All system ROMs must be upgraded at the same time see Compatibility Warning standard AMG operation at Annunciator address 29 30 31 or 32 EPROM for AMG 1 AMG E 15744 15889 Change Procedure for the AM2020 and AFP1010 Alarm Multiplex 2020 73284 73295 73529 73534 73759 73895 73760 73761 73790 73736 73737 P N 73895 Label a quick reference to the ROM soft level currently installed in the AFP1010 Assembly Place this label on the of the DIA 1010 door during installation the A1ROM6.6N DIA Mylar Security LED Overlay software is upgraded to this level the shown above must be placed over the DIA 1010 LED legend if the existing differs from the above for use with 5th through 8th AMG in one system at EPROM forAMG 1 AMG E 15744 15889 Change Procedure for the AM2020 and AFP1010 Alarm Multiplex 2020 address 25 26 27 or 28 zone coded AMG operation occupying addresses 2 3 4 and 5 EPROM for AMG 1 AMG E 15744 15889 Change Procedure for the AM2020 and AFP1010 Alarm Multiplex 2020 zone coded AMG operation occupying addresses 2 3 4 and 5 EPROM for AMG 1 AMG E 15744 15889 Change Procedure for the AM2020 and AFP1010 Alarm Multiplex 2020 EPROM for CPU 2 15744 15337 EPROM for DIA 1010 Label 15744 15987 15088 15088SUP Change Procedure for the AM2020 and AFP1010 AM2020 AFP1010 Fire Alarm Control Panel Instructions Change Procedure for the AM2020 and AFP1010 Instruction Sheet AM2020 AFP1010 Manual to Document 15088 EPROM for LIB 200 15744 Change Procedure for the AM2020 and AFP1010 EPROM for SIB 2048 15744 EPROM for XPP 1 15744 15888 EPROM for XPP 1 15744 15888 50190 50360 B 02 6 97 Change Procedure for the AM2020 and AFP1010 Change Procedure for the AM2020 and AFP1010 XP Series Transponder System use in Canada when the second stage evacuation must be activated steadily not at 120 PPM Change Procedure for the AM2020 and AFP1010 XP Series Transponder System to the XP Series Transponder System and A1ROM6.6N Special Features Notes Trouble Inhibit AM2020 AFP1010 monitors the primary RX line for error conditions This inhibits the generation of a trouble for Paper Out or Printer Off Line for VGAS UNINET applications only to Document 50251 Digital Alarm Transmitter feature allows the AM2020 AFP1010 to to and utilize the full functionality of the module refer to Document 50050 UDACT is not suitable for use when security are employed in the AM2020 AFP1010 33333 02 6097 AFP1010 Software Releases following features are included in the current software release Rev A Selectable Drift Compensation UL1076 UL1610 Security Rev B E Revised Standard for DACT Rev F G Zone Coded Voice Female Rev A B Rapid XP Transponder All Call Rapid Polling Algorithm Pre Alarm Option Remote Terminal Mode Supervisory Type ID Piezo Disabled During Alter Status Programming Pager Mode Rev B D Canadian Upgrade Kit Provides Second Stage Signal Rev B Printer Trouble Inhibit Universal Digital Alarm Transmitter Rev A Battery Charger Control Block Acknowledge Control By Time Control Module Reporting Day Night Sensitivity Device Blink Disabled Zones Event Reminder Expanded Read Status Functions Expanded AMG Addressing Expanded Status Line Expanded User Reports LED Latching Local Printer New Type IDs NIB 96 Trouble Reporting Non Alarm Module Reporting Periodic Detector Test Prior Next Autostep Keys Remote Page Verification Counter Reset Walk Test Zone Coded Synthesized Chime Zone Coded Voice Male Rev B New AMG Boards Rev C E NFPA 72 1993 Chapter 6 Sensitivity Test Drift Compensation Manual Reset of Automatically Activated Control Modules Warning Combinations All software part numbers are not compatible with each other Improper of software part numbers may compromise LifeSafety functions If in doubt about the compati of a particular software combination consult the factory AMNET AUTOPLEXOR and VGAS UNINET software is not compatible with earlier versions of CGAS AMNET AUTOPLEXOR and VGAS UNINET systems Software in these items must upgraded for compatibility 50360 B 02 6 97