Notifier B501BH Intelligent Base with Sounder
File Preview
Click below to download for free
Click below to download for free
File Data
Name | notifier-b501bh-intelligent-base-with-sounder-3982706514.pdf |
---|---|
Type | |
Size | 769.57 KB |
Downloads |
Text Preview
March 29 2004 cid 127 H 320 Base with Sounder Base with Sounder Base with Sounder Base with Sounder Base with Sounder Intelligent Addressable Devices Fire E2 Coast Guard AFP 200 NFS 640 B501BH is a mounting base which includes a horn Any NOTIFIER analog intelligent detector may used with the B501BH When the detector alarms it the sounder to activate Model B501BH Base Sounder may be used with the NFS 3030 NFS 640 AFP1010 AFP 200 AFP 300 AFP 400 or Sys 5000 equipped with AIM 200 module B501BH is ideal for applications where a sounder is at each detector location such as hotel rooms and patient rooms AND OPERATION B501BH may be used in two modes of operation 1 When the detector LEDs are latched on for 10 seconds the associated horn sounds 2 A loop of B501BH Sounder bases may be acti simultaneously by reversing the polarity of the 24 supply This feature may be used in conjunction with 1 for a type of evacuation B501BH sounder always requires separate 24 VDC to the sounder see Sounder Electrical Ratings p 2 Sounder output is greater than 90 dBA measured in an room at 10 feet 3.048 m 24 volts 85 dBA measured in UL reverberant room An alarm delay of approximately 10 seconds is built into B501BH shown with a smoke detector 72 and NEMA guidelines should be observed For installation in Canada refer to CAN ULC S524 for the Installation of Fire Alarm Systems See Part 1 Sec 32 Units must be mounted directly to a 101.6 mm square electrical box minimum 1.5 38.1 deep using the supplied mounting kit A maximum of 0.125 3.175 mm from outside edge of electrical to the inside edge of the drywall or ceiling tile is allow diameter 6.0 15.2 cm height less base and sensor 0.75 1.9 cm 0.3 lbs 140 grams temperature range 14 to 140 to relative humidity range 10 to 95 is a Honeywell company document is not intended to be used for installation purposes We try to keep our information up to date and accurate We cannot cover all specific applications or all requirements All specifications are subject to change without notice more information contact NOTIFIER Phone 203 484 7161 FAX 203 484 7118 Clintonville Road Northford Connecticut 06472 03 29 04 Page 1 of 2 ELECTRICAL RATINGS Supply 17 to 32 VDC current 1.0 mA maximum current 15 mA maximum ripple voltage 10 of supply voltage capacitance 200 Loop Power Requirements Current draw from remote output of detector to turn horn Intelligent systems requires 700 maximum Auxiliary devices such as the RA400Z may not be used conjunction with the B501BH A high current switching relay is required for both po when used for the external power supply The requires 1 mA each in the Standby mode and mA each in an Alarm condition The current capacity monitoring normal can be up to 99 mA 1 mA base without any horns sounding plus an addi 75 mA to 150 mA from local sensor control or up 1.5 Amperes with a polarity reversal and 99 mA with sounding LINE INFORMATION base assembly Includes B501 base flangeless base for 500 Series detec 2 of 2 DN 3170 cid 127 03 29 04