Notifier BACNET-GW-3 BACnet Gateway

File Preview
File Preview
Click below to download for free

File Data

Name notifier-bacnet-gw-3-bacnet-gateway-3586940721.pdf
Type PDF
Size 792.13 KB
Downloads

Text Preview

BACNET GW 3 Gateway BACNET GW 3 provides an interface between NOTIFIER fire panel network either the standard or the version and a network using the BACnet IP commu protocol BACnet protocol is an American National ANSI ASHRAE 135 1995 With the Gateway inter devices on NFN fire alarm control panels are represented BACnet objects to the BACnet client The user subscribes to Notification objects per FACP and the BACnet device events from objects on the FACP as a result of this sub BACNET GW 3 can be connected to a stand alone ONYX 9th edition with an available network port or it can be to NOTI via the network port on any net control module Connected to NOTI each BAC can support a maximum of 14 other nodes or 15,000 Multiple BACNET GW 3s can be used to interface with networks The BACNET GW 3 can monitor up to 14 NOTI with a maximum combined object count of 15,000 count includes all detectors monitor modules notifi appliance circuits etc Multiple BACNET GW 3s can be used for large networks than 15 nodes total Provides a built in configuration tool for simple browser con The NOTIFIER BACNET GW 3 can behave as a foreign BBMD when communicating with a Broadcast Management Devices ONYX Series Fire Panels NFS 320 NFS2 640 NFS2 ONYXWorks Workstation Other Devices Digital Voice Command NCA 2 NWS 3 NFN GW EM 3 PC NFN Gateways VESDA Standard and High speed NOTI NFN Power Input 24 VDC Power Supply The BACNET GW 3 must be powered by a Standard 1481 and or UL Standard 864 listed regulated VDC power supply Current 125 mA 24 VDC Temperature 0 to 49 32 120 Relative Humidity 93 non condensing at 32 F The BACNET GW 3 is connected to NOTI via a control module NCM or HS NCM The BACNET GW 3 is connected to the BACnet front end via standard RJ45 Ethernet connector A0 190 Systems The BACNET GW 3 installs in a single slot of a CAB 4 Series using a CHS 4 or CHS 4L chassis The PNET 1 suppressor is connected to the BACnet Ethernet via a Ethernet connector and Codes BACNET GW 3 complies with the following standards and BACnet Standard Annex J for IP and Support Device Binary Output Objects Life Safety Points Zones Multi State Inputs NFPA 70 National Electrical Code NFPA 72 National Fire Alarm Code NFPA 101 Life Safety Code UL 864 9th Edition Control Units for Fire Alarm Systems UL 2017 1st Edition General Purpose Signaling Devices Systems UL 2572 1st Edition Mass Notification Systems CAN ULC S559 04 1st Edition Standard for Equipment for Signal Receiving Centres and Systems Listings and Approvals listings and approvals below apply to the BACNET GW 3 In cases certain modules or applications may not be listed certain approval agencies or listing may be in process Con factory for latest listing status UL Listed S635 ULC Listed S635 CSFM 7300 0028 0250 New York Fire Dept COA 6158 Information ORDERED FROM NOTIFIER BACNET GW 3 Includes circuit board surge suppressor connection cables CAB 4 Series Enclosure Standard enclosure for NOTIFIER alarm control panels and peripherals available in four through Back box and door ordered sepa 08 04 2014 Page 1 of 2 Client A trim ring option is available for semi flush mounting DN 6857 CHS 4L Chassis for mounting N WEBPORTAL in a CAB 4 NCM For connecting to a standard NOTI net cabinet See DN 6861 HS NCM For connecting to a high speed NOTI See DN 60454 Power Supply Select a regulated 24 VDC power supply is listed to UL 1481 or UL 864 SUPPLIED BY CUSTOMER Computer Capable of running a web browser to configure BACNET GW 3 Web Browser Google Chrome preferred Firefox or Micro Internet Explorer version 10 or higher Ethernet Patch Cable RJ45 connectors For connecting to Local Area Network LAN for configura STATEMENT BACNET INFORMATION BACNET GW 3 PIC Statement available at Select products and then network systems information on the BACnet protocol see www bacnet org Architecture Network Panel Architecture Client Network Client Network Architecture ONYX and ONYXWorks are registered trademarks of and is a trademark of Honeywell International Inc BACnet is registered trademark of the American Society of Heating Refrigerating and Engineers ASHRAE Google is a registered trademark Chrome is a trademark of Google Inc FireFox is a registered of Mozilla Inc Microsoft and Windows are registered of Microsoft Corporation by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Notifier Phone 203 484 7161 FAX 203 484 7118 in the U S A 2 of 2 DN 6877 C 08 04 2014

Related Files