Notifier BEAM1224(A) and BEAM1224S(A) Conventional Beam Smoke Detectors

File Preview
File Preview
Click below to download for free

Text Preview

BEAM1224 A and Beam Smoke Detectors System Sensor BEAM1224 and BEAM1224S are four conventional reflected beam smoke detectors They are suited for protecting open areas with high ceilings spot type smoke detectors are difficult to install and BEAM1224 and BEAM1224S are to be used with UL compatible fire alarm control panels only Installation of single ended reflective design is much quicker than a dual projected beam detector Alignment is easily accom with an optical sight and a two digit signal strength incorporated into the beam detector Listed for operation to 131 the BEAM1224 and BEAM1224S can be in open area applications to provide early warning in where temperature extremes exceed the design for other types of smoke detection BEAM1224 and BEAM1224S are a transmitter receiver and a reflector When smoke enters the area between the and the reflector it causes a reduction in the signal When the smoke level signal strength reaches the threshold an alarm is activated The detectors four standard sensitivity selections as well as two Accli settings When either Acclimate setting is selected detector will automatically adjust its sensitivity using software algorithms to select the optimum sensitivity the specific environment BEAM1224S has an integral sensitivity test feature of a fil attached to a servomotor inside the detector optics Activa of the RTS151 or RTS151KEY remote test station moves filter into the pathway of the light beam testing the detec sensitivity This sensitivity test feature allows the user to and easily meet the annual maintenance and test of NFPA 72 without physical access to the Unless otherwise specified the term BEAM1224 is used in data sheet to refer to both the BEAM1224 and the Likewise BEAM1224S BEAM1224SA version Transmitter receiver built into same unit Six user selectable sensitivity levels 16 to 328 use BEAMLRK beyond 230 protection range Removable plug in terminal blocks Digital display for easy alignment Built in automatic gain control compensates for signal dete from dust buildup Paintable cover Optional remote test station Optional long range kit BEAMLRK for applications in of 230 70 m Optional multi mount kit BEAMMMK providing ceiling or mount capability with increased angular adjustment Optional heater kits BEAMHK and BEAMHKR for preven of condensation not intended to increase or reduce the operating temperature Optional heavy duty mounting bracket 6500 MMK cid 129 I 405 Initiating Devices Reflective Plate BEAMMMK separately SPECIFICATIONS range 16 to 230 feet 5 to 70 m 230 to 328 feet to 100 m using optional BEAMLRK kit angle horizontal and vertical Note that the move independently of the unit 6 levels Level 1 25 Level 2 30 Level 3 40 Level 4 50 Acclimate Level 5 30 to 50 Acclimate Level 6 40 to 50 condition trouble 96 or more obscuration blockage Self compensation limit reached aid Optical gunsight Two digit display Alarm local red LED and remote alarm Trouble local yellow LED and remote trouble Normal local flashing green LED features sensitivity test filter BEAM1224S only requires exter power supply Sensitivity filter incremental scale on reflector alignment mode initial alignment signal strength indication 08 26 2009 Page 1 of 2 Listings and Approvals listings and approvals apply to the modules specified in document In some cases certain modules or applications not be listed by certain approval agencies or listing may in process Consult factory for latest listing status UL Listed S911 ULC Listed S911 MEA Listed 54 04 E Maryland State Fire Marshal Permit 2165 CSFM 7260 1653 168 FM Approved Line Information suffix indicates ULC listed model Conventional beam smoke detector Conventional beam smoke detector with sensitivity test Long range accessory kit required for applica in excess of 230 ft 70 m Multi mount kit provides ceiling or wall mount with increased angular adjustment Surface mount kit Heavy duty multi mount kit for installations prone vibration or where there is difficulty maintaining the set When installed with the transmitter receiver unit is also required Surface mount kit for use with 6500 MMK Remote test station Replaces RTS451 Remote test station with key lock Replaces Heating kit for use with the transmitter receiver unit BEAM1224 S For prevention of condensation Heating kit For prevention of condensation reflector of use with Local alarm test switch Local alarm reset switch Remote test and reset switch compatible with RTS151 and test stations detector spacing On smooth ceilings 30 60 feet to 18.3 m between projected beams and not more than that spacing between a projected beam and a side Other spacing may be used depending on ceiling height characteristics and response requirements See NFPA SPECIFICATIONS to 131 to 55 10 93 RH noncondensing SPECIFICATIONS 10.2 to 32 VDC BEAM1224 15 to 32 VDC current 24 VDC 17 mA maximum current 24 VDC 38.5 mA maximum mode current 24 VDC 28 mA maximum mode current BEAM1224S only 500 mA maximum test contacts 0.5 A 30 VDC time 0.3 seconds maximum time after 2 min reset 60 seconds maximum verification time 5 seconds maximum output alarm or trouble Voltage 15 to 32 VDC Output voltage is the same as device input voltage 15 mA maximum 6 mA minimum NOTE Output cur is limited by 2.2K ohm resistor kit BEAMHK Voltage 15 to 32 V Current 92 mA 32 V heater only Power consumption nominal W 24 V maximum 3.0 W 32 V kit BEAMHKR Voltage 15 to 32 V Current 450 mA 32 V per reflector Power consumption per nominal 7.7 W 24 V maximum 15.0 W 32 V SPECIFICATIONS weight 3.9 lbs 1.77 kg Plug in terminal blocks 12 to 22 AWG 3.1 to 0.33 dimensions 10.0 H x 7.5 W x 3.3 D 254 mm H x mm W x 84 mm D dimensions for 16 to 230 5 to 70 m applica 7.9 x 9.1 200 x 230 mm dimensions for applications beyond 230 m x 18.1 400 x 460 mm Plus and System Sensor are registered trademarks of International Inc by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Notifier Phone 203 484 7161 FAX 203 484 7118 in the U S A 2 of 2 DN 6975 B cid 129 08 26 2009

Related Files