Notifier MODBUS-GW Modbus Gateway
File Preview
Click below to download for free
Click below to download for free
File Data
Name | notifier-modbus-gw-modbus-gateway-5019487263.pdf |
---|---|
Type | |
Size | 701.52 KB |
Downloads |
Text Preview
MODBUS GW Gateway Modbus Gateway provides a communication networks that use the Modbus TCP communication and Fire Alarm Control Panels FACPs resident on NFN network Modbus Gateway communicates with the NOTI FIRE network via the network port on any NCM The Modbus protocol is consistent with Modbus Applica Protocol Specification V1.1b Modbus Gateway is designed to need very little configu no separate configuration utility is required In most you will only need to enter the TCP IP settings your network and the nodes you would like to monitor The will automatically map all the configured points and you with a user friendly comma separated value that defines the mapping Compatible with standard and high speed NOTI FIRE Provide data such as event type active inactive enabled acknowledged unacknowledged device type value 4 20ma modules only and system troubles Support reads of up to 100 registers at a time Analog val can be read 10 registers at a time Log diagnostic information Send standard Modbus exception responses Reduce configuration time by auto discovering and map points MASTERS COMPATIBLE The Modbus Gateway was designed to be compatible with Modbus TCP masters Support one byte Unit IDs Have configurable polling times The Modbus Gateway supports one Modbus Master COMPATIBLE Modbus Gateway was designed to be compatible with following panels NFS 320 NFS 640 NFS2 640 NFS 3030 NFS2 3030 Monitor four compatible NFN or HS NFN nodes not includ the Modbus Gateway node itself Systems and Codes Modbus Gateway is recognized by UL as an ancillary reporting device It complies with the follow UL ULC Standards and NFPA 72 Fire Alarm Systems UL 864 Control Units for Fire Alarm Systems Ninth Edi UL 2017 General Purpose Signaling Devices and Sys First Edition CAN ULC S527 99 Standard for Control Units for Fire Systems Second Edition CAN ULC S559 04 Equipment for Fire Signal Receiving and Systems First Edition and Approvals listings and approvals apply to the modules specified this document In some cases certain modules or applica may not be listed by certain approval agencies or listing be in process Consult factory for latest listing status UL ULC Listed S635 CSFM 7300 0028 250 FDNY COA 6047 Architecture Requirements Internet or Intranet IP network connection is required to the Modbus Gateway and to connect it with Mod clients The Internet or Intranet IP network connection meet the following requirements Private of Business LAN Static IP address required Standard 100Base T connection Required Ports s 502 EQUIPMENT MODBUS GW NFN Modbus Embedded Gateway Network Control Module NFN Network Version 5.0 or above 03 10 2010 Page 1 of 2 Network COMPONENTS RJ45 to RJ45 standard Ethernet network cable cus internet or intranet connection to Modbus Gateway NFN network version 5.0 or above sold separately High Speed Network Communication Module HS NCM board used to facilitate network communication the Modbus Gateway and a High Speed NFN or Network Communication Module NCM W F to facilitate network communication between Modbus Gateway and an NFN network Cabinet and Hardware sold separately CAB 4 series cabinet CHS 4L chassis SUPPLIED EQUIPMENT Windows XP Professional with Internet Explorer running version 6 or higher Network System Modbus Gateway to Fire Alarm Control Panel System Modbus Gateway on NOTI FIRE Network is a registered trademark of and NOTI is a trademark Honeywell International Inc Modbus is a registered trademark of the Organization Inc document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Notifier Phone 203 484 7161 FAX 203 484 7118 in the U S A 2 of 2 DN 60533 B 03 10 2010