Name | notifier-monitor-modules-nmm-100-a-nmm-100p-a-nzm-100-a-and-ndm-100-a-for-firewarden-series-0846125379.pdf |
---|---|
Type | |
Size | 811.00 KB |
Downloads |
Text Preview
Monitor Modules NMM 100P A NZM 100 A NDM 100 A for FireWarden Series different monitor modules are available for Notifier Series intelligent control panels for a variety of Monitor modules supervise a circuit of dry con input devices such as conventional heat detectors and stations or monitor and power a circuit of two wire detectors NZM 100 A is a standard sized module typically mounts to 4 10.16 cm square box that supervises either a Style D A or Style B Class B circuit of dry contact input is a miniature monitor module a mere 1.3 cm H x 2.75 6.985 cm W x 0.65 1.651 cm D that a Style B Class B circuit of dry contact input Its compact design allows the NMM 100P A to be in a single gang box behind the device it monitors is a standard sized module that monitors and compatible two wire 24 volt smoke detectors on Style D Class A or Style B Class B circuit is a standard sized dual monitor module that and supervises two independent two wire Style B B dry contact initiating device circuits IDCs at two consecutive addresses in intelligent two wire sys greatly the speed of communication between analog intel devices Intelligent devices communicate in a grouped If one of the devices within the group has new infor the panel CPU stops the group poll and concentrates single points The net effect is response speed greater five times that of other communication protocols a communication protocol Monitor Module Built in type identification automatically identifies this as a monitor module to the control panel Powered directly by two wire SLC loop No additional required High noise EMF RFI immunity SEMS screws with clamping plates for ease of wiring Direct dial entry of address 01 99 on FireWarden 100 01 50 on FireWarden 50 LED flashes during normal operation and latches on to indicate alarm NMM 100 A Monitor Module is intended for use in intel two wire systems where the individual address of module is selected using the built in rotary switches It either a two wire or four wire fault tolerant Initiating Circuit IDC for normally open contact fire alarm and devices The module has a panel controlled LED APPLICATIONS to monitor a zone of four wire smoke detectors manual alarm pull stations waterflow devices or other normally dry contact alarm activation devices May also be used Addressable Devices Type H monitor normally open supervisory devices with special indication at the control panel Monitored circuit be wired as an NFPA Style B Class B or Style D Class Initiating Device Circuit A 47K Ohm End of Line Resistor terminates the Style B circuit No resistor is for supervision of the Style D circuit OPERATION NMM 100 A uses one of the available module on an SLC loop It responds to regular polls from control panel and reports its type and the status open of its Initiating Device Circuit IDC A flashing indicates that the module is in communication with the panel The LED latches steady on alarm subject to limitations on the loop SPECIFICATIONS operating voltage 15 to 32 VDC current draw 5.0 mA LED on operating current 375 LED flashing 1 com every 5 seconds 47k EOL IDC wiring resistance 1500 Ohms IDC Voltage 11 Volts resistance 47K Ohms range 32 to 120 0 to 49 range 10 to 93 noncondensing 4.5 11.43 cm high x 4 10.16 cm wide x 3.175 cm deep Mounts to a 4 10.16 cm square x 5.398 cm deep box Mini Monitor Module Built in type identification automatically identifies this as a monitor module to the panel 07 30 2015 Page 1 of 4 Powered directly by two wire SLC loop No additional length 6 15.24 cm minimum required High noise EMF RFI immunity Tinned stripped leads for ease of wiring Direct dial entry of address 01 99 on FireWarden 100 2 50 on FireWarden 50 Interface Module Supports compatible two wire smoke detectors Supervises IDC wiring and connection of external power High noise EMF RFI immunity SEMS screws with clamping plates for ease of wiring Direct dial entry entry of address 01 99 on FireWarden 01 50 on FireWarden 50 LED flashes during normal operation LED latches steady to indicate alarm on command from panel NZM 100 A Interface Module is intended for use in addressable systems where of each module is selected using built in rotary This module allows intelligent panels to interface monitor two wire conventional smoke detectors It trans the status normal open or alarm of one full zone of detectors back to the control panel All two wire being monitored must be UL compatible with the APPLICATIONS the NZM 100 A to monitor a zone of two wire smoke The monitored circuit may be wired as an NFPA B Class B or Style D Class A Initiating Device Cir A 3.9 K Ohm End of Line Resistor provided terminates end of the Style B or D class B or A circuit maximum loop resistance is 25 Ohms Install ELR across termi 8 and 9 for Style D application OPERATION NZM 100 A uses one of available module on an SLC loop It responds to regular polls from control panel and reports its type and the status open of its Initiating Device Circuit IDC A flashing indicates that the module is in communication with the panel The LED latches steady on alarm subject to limitations on the loop SPECIFICATIONS operating voltage 15 to 32 VDC current draw 5.1 mA LED on IDC wiring resistance 25 Ohms operating current 270 1 communication and LED flash every 5 seconds 3.9k eol resistance 3.9K Ohms supply voltage between Terminals T10 and DC voltage 24 volts power limited Ripple voltage 0.1 Vrms maximum Current 90 mA per module maximum range 32 to 120 0 to 49 range 10 to 93 noncondensing 4.5 11.43 cm high x 4 10.16 cm wide x 3.175 cm deep Mounts to a 4 10.16 cm square x 5.398 cm deep box NMM 100P A Mini Monitor Module can be installed in a junction directly behind the monitored unit Its size and light weight allow it to be installed without rigid The NMM 100P A is intended for use in intelli two wire systems where the individual address of each is selected using rotary switches It provides a two initiating device circuit for normally open contact fire and security devices NMM 100P A APPLICATIONS to monitor a single device or a zone of four wire smoke manual fire alarm pull stations waterflow devices other normally open dry contact devices May also be to monitor normally open supervisory devices with spe supervisory indication at the control panel Monitored cir is wired as an NFPA Style B Class B Initiating Circuit A 47K Ohm End of Line Resistor provided the circuit OPERATION NMM 100P A uses one of the available module on an SLC loop It responds to regular polls from control panel and reports its type and the status open of its Initiating Device Circuit IDC SPECIFICATIONS operating voltage 15 to 32 VDC operating current 350 1 communication 5 seconds 47k EOL 600 Max Communicating Shorted IDC wiring resistance 1500 Ohms IDC Voltage 11 Volts IDC Current 450 resistance 47K Ohms range 32 to 120 0 to 49 range 10 to 93 noncondensing 1.3 3.302 cm high x 2.75 6.985 cm wide x 1.651 cm deep 2 of 4 DN 6999 E 07 30 2015 Dual Monitor Module NDM 100 A Dual Monitor Module is intended for use in two wire systems It provides two indepen