Notifier N-ANN-LED Annunciator Module
File Preview
Click below to download for free
Click below to download for free
File Data
Name | notifier-n-ann-led-annunciator-module-9403625817.pdf |
---|---|
Type | |
Size | 699.40 KB |
Downloads |
Text Preview
N ANN LED Module N ANN LED annunciator module provides LED annuncia of general system faults and input zones points when used a compatible Fire Alarm Control Panel FACP The N ANN module provides alarm red trouble yellow and supervi yellow indication for up to ten input zones or addressable N ANN RLED has red LEDs only for alarm communica of up to 30 addressable points N ANN LED is supplied standard with Canadian Firewar FACPs as required by ULC The Canadian part number are below with a C N ANN LED and the FACP communicate over a two wire interface employing the ANN BUS communication format additional two wires are used for 24 volt DC power A single unshielded cable may be used for both power data communications to eight ANN BUS devices may be connected to the ANN of each FACP N ANN LED connects to the ANN BUS terminal on the FACP requires minimal programming three LEDs for each zone Alarm Trouble and N ANNRLED includes all red LEDs for alarm annunciation Compatible with NFW 50 C NFW2 100 C SFP SFP 10UD C RP 2001 C RP 2002 C Can be remotely located up to 6,000 feet 1,829 m from the May be powered by 24 VDC from the host FACP or by remote supply requires 24 VDC Maximum ANN BUS Voltage 24 VDC Maximum Current Alarm 68 mA Standby 28 mA Maximum wiring distance from FACP 6,000 ft 1,829 m Ambient Temperature 32 to 120 0 to 49 Relative Humidity 93 2 RH noncondensing at 32 90 3 For use indoors in a dry location Connections to FACP are power limited and supervised 5.160 13.11 cm high x 10.043 25.51 cm wide x 1.77 cm deep Listings and Approvals listings and approvals below apply to the N ANN LED In cases certain modules may not be listed by certain agencies or listing may be in process Consult factory latest listing status UL S635 ULC S635 N ANN LED only FM approved CSFM 7120 0028 0259 MEA 333 07 E Fire Dept of NY COA 6177 ANN BUS THE DEVICES ON THE ANN BUS FROM POWER SUPPLY devices can be powered by an auxiliary power supply available panel power is exceeded See FACP manual for DEVICE ADDRESSING ANN BUS device requires a unique address ID Number order to communicate with the FACP A maximum of eight can be connected to the FACP ANN BUS communica circuit See the FACP manual for more information REQUIREMENTS N ANN LED connects to the FACP ANN BUS communica circuit To determine the type of wire and the maximum wir distance calculate the total worst case current draw for all on a single 4 conductor bus Use the table on the fol page to determine the maximum distance the modules be located from the FACP In general the wire length is lim by resistance but for heavier wire gauges capacitance is limiting factor These cases are marked in the chart with an Maximum length can never be more than 6,000 feet m regardless of gauge used to the appropriate FACP manual for wiring details and settings Information annunciator module with alarm red trouble yel and supervisory yellow indication for up to ten input zones addressable points includes module mounting bracket metal and clear plastic screen rubber display label holder for securing the metal cover and the backbox black same as above with red enclosure annunciator module with alarm red indicators up to 30 input zones or addressable points includes black annunciator module with alarm red indica for up to 30 input zones or addressable points includes red 10 7 14 Page 1 of 2 max Pair Wiring Distance FACP to last ANN BUS Module Worst Case Draw amps Gauge Gauge Gauge Gauge ft 565 m ft 282 m ft 188 m ft 141 m ft 113 m ft 94 m ft 81 m ft 70 m ft 63 m ft 56 m ft 1,429 m ft 715 m ft 476 m ft 357m ft 286 m ft 238 m ft 204 m ft 179 m ft 159 m ft 143 m 6,000 ft 1,829 m ft 1,137 m ft 758 m ft 569 m ft 455 m ft 379 m ft 325 m ft 284 m ft 253 m ft 227 m 6,000 ft 1,829 m ft 1,800 m ft 1,200 m ft 900 m ft 720 m ft 600 m ft 514 m ft 450 m ft 400 m ft 360 m is a registered trademark of Honeywell International Inc by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Notifier Phone 203 484 7161 FAX 203 484 7118 in the U S A 2 of 2 DN 60242 D 10 7 14