Notifier NCD Network Control Display

File Preview
File Preview
Click below to download for free

File Data

Name notifier-ncd-network-control-display-5136489027.pdf
Type PDF
Size 795.71 KB
Downloads

Text Preview

NCD Network Control Display Network Control Display NCD is the next generation of net control annunciators for the NOTI network With new modern contemporary design the NCD meets todays build aesthetic needs The intuitive 1024 x 600 10 color touch provides color coded information of detailed system status point information It is compatible with ONYX Series nodes as the NFS2 3030 NFS 320 and NFS2 640 fire alarm con panels as well as the NCA 2 The NCD provides system con and display capabilities for all or for selected network nodes in a standalone configurations the NCD can be used the primary display for control and status capabilities on display node by utilizing Direct Connect connected to one or more networked panels the NCD pro network control and status history display capabilities Features Full supervision of all inputs and network integrity High definition 10 1024 x 600 color touchscreen display LED status indicators Requires 24 VDC and a network connection or direct connect Three USB 2.0 connections USB C USB Micro and USB A Trouble Relay Tamper and Trouble inputs Features Device information including point address and description can quickly identified Summary Event Count display and event handling user guidance program Network wide Acknowledge Silence Reset Lamp Test Fully programmable node mapping subsystem Environmental adjustment controls to maximize display legibility Color coded Icon based event notification Can be used as FACP primary display Supports standard and high speed network systems Event vectoring for quick viewing of event groups Virtual alphanumeric QWERTY keypad and numeric keypad dis when data input is needed Enable Disable or group Enable Disable for networked series panels Control ON OFF for networked ONYX series panel control points Read Status networked ONYX series panel points and zones History Buffer 10,000 events 3000 displayed Up to 50 unique users and 5 different user levels Read Status from event display History filters for report displaying Timer control for Auto Silence AC Fail Delay Custom wallpaper Indicators and Controls INDICATORS LED illuminates when 24 VDC power is applied When on backup the green LED will not illuminate LED illuminates when an off normal condition exists EVENT INDICATORS FIRE ALARM red illuminates when at least one fire alarm event CO Alarm blue illuminates when at least one CO alarm event SUPERVISORY yellow illuminates when at least one supervi event exists i e sprinkler valve off normal low pressure pump running guard tour etc TROUBLE yellow illuminates when at least one trouble event POINT DISABLED yellow illuminates when at least one disable on the network or in the system OTHER varies illuminates for SECURITY PRE ALARM CO and CRITICAL PROCESS SIGNALS SILENCED yellow illuminates if the NCD Silence point has been pressed or if any other node sent a Network command 3 5 19 Page 1 of 2 High speed network com modules Wire single mode fiber multi mode fiber media conversion models are available See DN 60454 Ten inch display annunciator Backbox Surface black NCD and one network control module Series Enclosure Available in four sizes through Backbox and door ordered separately requires BP2 4 battery See DN 6857 Graphic Annunciator Dress Plate Dress plate is used the 10 graphic display is mounted in CAB 4 Series cabinet top row Graphic Annunciator Dress Plate Dress plate is used the 10 graphic display is mounted in the top row of a CAB 4 cabinet Listings and Approvals listings and approvals apply to the NCD In some cases modules or applications may not be listed by certain agencies or listing may be in process Consult factory for listing status Listed S635 7300 0028 0507 Approved TOUCHPOINTS Menu Login Acknowledge Signal Silence System Reset Acknowledge Tap this touchpoint to acknowledge off all events Signal Silence Tap this touchpoint to turn off all control notification appliance circuits and panel output circuits have been programmed as Silenceable System Reset Tap this touchpoint to clear all latched and other events and clear event indicators FUNCTION TOUCHPOINTS function touchpoint are accessible though the menu dialogs ABOUT tap this touchpoint to view current firmware and hard revision numbers DISPLAY tap this touchpoint to adjust display settings LAMP TEST tap this touchpoint to test display pixels LED indi and piezo and humidity ranges This system meets NFPA for operation at 0 to 49 32 to 120 and at a humidity non condensing of 85 at 30 86 per However the useful life of the system standby batteries the electronic components may be adversely affected by temperature ranges and humidity Therefore it is recom that this system and all peripherals be installed in an envi with a nominal room temperature of 15 to 27 60 to Product weight is 3 lbs 1.36 kilograms REQUIREMENTS NCD may be powered from any UL Listed non resettable 24 source from a NOTIFIER compatible fire panel see panel sheets Power source 1 AMPS 24 120 VAC 50 60 Hz or 240 VAC 50 60 Hz power supply 2 the NFS2 640 NFS 320 on board power supply or 3 a supervised 24 VDC supply that is UL listed for fire protective service The cur consumption of the NCD is 360 mA Line Information Network Control Display Requires a network communica module for networking In direct connect applications the is not required NCM F Standard Network Communications Modules and multi mode fiber versions available See DN 6861 Clintonville Road CT 06472 document is not intended to be used for installation purposes try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice is a trademark of and NOTIFIER and are registered trademarks of Honeywell Interna Inc by Honeywell International Inc All rights reserved use of this document is strictly prohibited of Origin USA

Related Files