Notifier ND-100 and ND-100R Low-Flow Photoelectric Duct Smoke Detectors for FireWarden Series Panels

File Preview
File Preview
Click below to download for free

Text Preview

52398pho1 jpg and ND 100R Photoelectric Duct Smoke for FireWarden Series Panels ND 100 and ND 100R Photoelectric Duct Detectors provide duct smoke detection throughout a broad range of air environments in HVAC applications The low flow technol can detect smoke at air speed velocities of 100 feet per 0.5 m sec or greater while continuing the same reliable to 4,000 feet per minute 20.32 m sec The intelli low flow duct detectors sample air currents passing a duct and gives dependable performance for shutdown fans blowers and air conditioning systems preventing the of toxic smoke an fire gases through the protected area and ND 100R are used exclusively with the NOTIFIER Series addressable control panels ND 100 and provide a remote alarm output for use with auxiliary such as the RA400Z A remote LED annunciator as as RTS451 A or Remote Test Stations The ND 100R features a relay capability with smoke detectors have specific limitations they are NOT a substitute for open area smoke detectors NOT a substitute for early warning detection NOT a replacement for a building regular fire detection sys call NOTIFIER for a copy of System Sensor application Proper Use of Smoke Detectors in Duct Applications Air velocity rating from 100 to 4,000 feet per minute 0.5 to m sec Patented telescopic sampling tube Easily accessible code wheels for addressing detector Outside mounting tabs Mounts to round or rectangular ducts from 1 to 12 0.3 to 3.7 wide Transparent cover for convenient visual inspection Powered outputs for remote LED and remote test and Two Form C auxiliary contacts ND 100R Patented cover tamper trouble signal ND 100R ND 100R requires both com line power and one of the follow 24 VAC VDC or 120 220 VAC for operation to installation manuals for control panel and duct detector detailed information or to install equipment Installation man for detectors I56 2853 000R for ND 100 I56 2854 000R ND 100R For signal wiring the wiring between detectors or from to auxiliary devices it is recommended that single wire be no smaller than 18 AWG 0.821 mm The smoke detector terminals accommodate wire sizes up to 12 3.31 mm Flexible conduit is recommended for the last A1 340 30.48 cm of conduit solid conduit connections may be if desired detectors and alarm system control panels have specifica for Signaling Line Circuit SLC wiring Consult the control specifications for wiring requirements before wiring the loop The detectors are designed for ease of wiring their provides a terminal strip with clamping plates Features If programmed with the system control panel LEDs on each duct smoke detector light to provide local vis indication specifications requirements for intelligent control panels The number of devices that can have LEDs programmed to illuminate is limited by the features of panel and the individual devices The actual number of is determined by the control panel and its ability to sup LED current Refer to the control panel installation manual details 01 14 09 Page 1 of 2 Line Information Addressable low flow duct detector housing with pho smoke detector Addressable low flow duct detector housing with smoke detector with DPDT relay Replacement photoelectric sensor board Replacement power board without relay Replacement power board with relay Metal sampling tube duct widths 1 to 2 see Inlet Tube table on page 2 for metric lengths Metal sampling tube duct widths 2 to 4 Metal sampling tube duct widths 4 to 8 Metal sampling tube duct widths 8 to 12 Remote annunciator alarm LED Remote test station Mounts in single gang box red alarm LED and magnet test switch Key activated remote test station Replacement filters Test magnet Test magnet with telescoping handle Replacement photo insect screen Replacement end cap for plastic sampling tube Replacement end cap for metal sampling tube Replacement plastic sampling tube ND 100 voltage range 15 to 30 VDC current 300 24 VDC one communication every seconds with LED blink enabled temperature range 32 to 131 0 to 55 humidity range 10 to 93 relative humidity non temperature range to 158 to 70 air velocity 100 to 4,000 feet min 0.5 to 20.32 m s weight 3.35 lbs 1.5 kg 14.75 37 cm length x 5.50 14 cm width x 7 cm deep accessory current loads 24 VDC PA400 refer to data sheet DN 2405 RA400Z 0 mA standby 10 mA in alarm RTS451 and RTS451KEY 0 mA standby mA maximum in alarm ND 100R voltage range 20 to 30 VDC 24 VAC VDC 120 240 auxiliary power requires a separate auxiliary source current 300 24 VDC one communication every seconds with LED blink enabled temperature range 32 to 131 0 to 55 humidity range 10 to 93 relative humidity non temperature range to 158 to 70 air velocity 100 to 4,000 feet min 0.5 to 20.32 m s weight 3.90 lbs 1.8 kg 14.75 37 cm length x 5.50 14 cm width x 7 cm deep CONTACT RATINGS auxiliary contacts DPDT 10 A 30 VDC 10 A VAC 0.75 power factor 240 VA 249 VAC 0.4 power 1 8 HP 120 VAC 1 4 HP 240 VAC switching current for auxiliary contact must be mA DC minimum 5 VDC contact SPST 2.0 A 30 VDC resistive accessory current loads 24 VDC PA400 refer to data sheetDN 2405 RA400Z 0 mA standby 12 mA in alarm RTS451 and RTS451KEY 0 mA standby mA maximum in alarm NO CURRENT REQUIREMENTS 30 VDC power supply voltage 26 mA maximum standby 87 mA maximum alarm current 3 to 10 second alarm time 2 second power up time VAC 50 60 Hz power supply voltage 65 mA RMS maxi standby current 182 mA RMS maximum alarm current 3 10 second alarm response time 2 second power up time VAC 50 60 Hz power supply voltage 44 mA RMS maxi standby current 52 mA RMS maximum alarm current 3 to second alarm response time 2 second power up time VAC 50 60 Hz power supply voltage 25 mA RMS standby current 30 mA RMS maximum alarm current to 10 second alarm response time 2 second power up time Listings and Approvals listings and approvals below apply to ND 100 and ND 100R Low Flow Photoelectric Smoke Duct Detectors In cases certain modules may not be listed by certain agencies or listing may be in process Consult factory latest listing status UL Listed files S635 ND 100 S1115 ND 100R CSFM approved files 3240 0028 232 ND 100R and 3240 ND 100 FM approved MEA approved 320 02 E Vol 2 Maryland State Fire Marshal approved Permits 2173 ND 2174 ND 100 Tube Selection Duct Width to 2 feet 0.6096 m to 4 feet 0.6096 to 1.21292 m to 8 feet 1.21292 to 2.4384 m to 12 feet 2.4384 to 3.6576 m Tube tube is required and must be purchased seperately Order one inlet tube for each duct smoke detec ordered and System Sensor are registered trademarks of Honeywell Inc by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Notifier Phone 203 484 7161 FAX 203 484 7118 2 of 2 dn 7006 A

Related Files