Notifier ONYX FirstVision Data Sheet

File Preview
File Preview
Click below to download for free

File Data

Name notifier-onyx-firstvision-data-sheet-5439718026.pdf
Type PDF
Size 2.09 MB
Downloads

Text Preview

ONYX FirstVision Interactive Firefighters Display FirstVision is a revolutionary wayfinding navigational tool for and other emergency responders ONYX FirstVision screen interface graphically displays critical information on the and spread of a fire allowing firefighters to quickly locate and the fire ONYX FirstVision emergency responders can immediately the information needed to accurately pinpoint the source of fire and the rate at which it spreading Crucial information is to access with a spatial graphical depiction of the location of detectors and detector sequence of activation for one or buildings In addition ONYX FirstVision is an interactive It displays a summary of building floor plans with detailed about the building Details can include locations for all alarm devices water supplies evacuation routes access routes and structural hazards in the building and shutoffs for gas and HVAC 22 LCD touch screen with ONYX Series panels or NOTI version or higher through the NFN Gateway over Ethernet Compatible with standard and high speed NOTI Supports the following additional languages French Canadian Korean Portuguese Spanish Thai and Chinese Tradi and Simplified Supports multiple gateways for large networks and campuses INTERFACE Large intuitive display shows building floor plans in a campus with respective active fire alarm devices water supplies routes access routes gas power and HVAC shut and chemical and structural hazards in the building Detailed information for active devices or critical building icons on floor plan Easy access to building emergency contacts site plan and event information Able to print screenshots Materials Safety Datasheet MSDS attachment User download of event log file NOTIFICATION Graphic and text event notification of fire supervisory security medical events events Fast automatic navigation to floors and locations of the emer Priority based event list display First alarm display to identify where the emergency started Time sequence display of activated detectors to track smoke pro Configurable sound notification with silence selection Configurable to unlock door based on events SETUP Shared configuration tool with ONYXWorks can easily import floor plan CAD drawings as a dxf wmf bmp or jpg and VeriFire Tools databases Standard icon library indicates fire alarm and critical building Ethernet and USB ports available for transferring screen data information ONYX FirstVision display is an ideal component of a NOTIFIER system providing real time fire system status to firefighters and emergency responders ONYX FirstVision interfaces directly ONYX Series control panels and an entire NOTI net ONYXWorks equipment options requirements are avail on the NFN Gateway data sheet 1 13 21 Page 1 of 4 Diagram Example connection Ethernet version 5.0 or FirstVision Network Control FirstVision Software This is not a complete list of all the icons The following icons are a representative sample ICONS of Page 2 of 4 DN 7051 G 1 13 21 Floor Plan View Event List Information Window 1 13 21 Page 3 of 4 Dimensions are subject to change Contact NOTIFIER for further Enclosure 24.53 W X 21.92 H X 3.47 D cm H x 55.68 cm W x 8.81 cm D Door 26.70 W X 23.06 H X 0.41 D cm H x 58.57 cm W x 1.0 cm D Requirements Regulated filtered 24 VDC 3.0 A via non power supply UL Listed for fire protective signaling use Temperature 32 to 120 0 to 49 and Approvals listings and approvals apply to ONYX FirstVision Consult for latest listing status UL ULC Listed S5697 CSFM 7300 1525 0103 FDNY NFS2640 320 NFS2 3030 Information This product is warrantied from date of purchase for a of 15 months Refer to NOTIFIER Limited Warranty Policy additional information ONYX FirstVision user interface software and package Includes 22 LCD touch screen onboard Ether and USB ports Also includes one software license and screen software FIRSTVISION SCT Does not include back order separately ONYX FirstVision backbox enclosure and door required components NOTI Gateway P N NFN GW EM 3 or NFN GW PC Series Network Control Module NCM W NCM F or HS NCM WMF 2 for connection to Standard Ethernet network cable with RJ45 connectors Standard Ethernet network cable with RJ45 connectors and hub or Standard Ethernet crossover cable PC with Windows Professional compatible and available or USB port used for programming Clintonville Road CT 06472 document is not intended to be used for installation purposes try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice ONYX and VeriFire are registered trademarks and and FirstVision are trademarks of Honeywell Inter Inc Microsoft and Windows are registered trademarks of Mic Corporation by Honeywell International Inc All rights reserved Unauthorized of this document is strictly prohibited of Origin USA

Related Files