Notifier PSE-6 PSE-10 Series 6 10 Amp, 24 Volt Power Supply Expanders Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

PSE 6 PSE 10 Series 6 10 Amp 24 Volt Power Supply Expanders PS Series is a remote power supply line from NOTIFIER and is direct replacement for the FCPS 24S6 8 Series The PSE 6 C E a 6 amp and the PSE 10 C E is a 10 amp remote power supply battery charger that may be connected to any 12 or 24 volt fire control panel FACP or used as a standalone power supply PS Series provides 24 VDC power for NACs notification appli circuits configured as either Class B or Class A requires the option card with multiple sync protocol options The PS also provides auxiliary power constant or resettable suited detectors annunciators door holders and other fire alarm sys peripherals The PS Series cabinet can hold two 7 AH or 18 AH and can charge up to 33 AH batteries in a separate cabi The PSE 6E and PSE 10E are models rated for 240V opera Up to five 6 amp model or seven 10 amp model inde power limited output circuits for Class B and or Class A NACs Class B and or Class A resettable or non resettable 24V auxil power door holder power Converts from Class B to Class A wiring without losing any out using the ZNAC PS converter card sold separately Optimal for powering four wire smoke detectors annunciators other system peripherals requiring regulated power Configurable for ANSI Temporal 3 or Temporal 4 coded output UL Listed NAC synchronization using System Sensor Whee Gentex or AMSECO appliances Synchronization can be triggered from FACP NAC remote sync cascaded power supply or a control module single or which may be housed within the power supply cabinet Ability to cascade up to four power supplies Two 6 amp model or three 10 amp model fully isolated input circuits which can be programmed to any output Two Form C normally closed trouble relays for AC Trouble and Trouble Ground Fault relay available on Canadian mod only 6 or 10 amp full load output respectively with 3 A maximum cir NAC power and trouble LEDs for diagnostic efficiency Trouble history modes for diagnostic support Wide range end of line supervision value normal 2K 27K ohms Selectable earth fault detection enable or disable AC trouble report delay timer Completely configurable via onboard DIP switches no extra soft required Self contained in compact locking cabinet constructed of heavy steel with a corrosion resistant powder coat chip and finish Cabinet designed with ten double knockouts and a removable for ease of installation and wiring integral battery charger capable of charging up to 33 AH Cabinet can house two 7 AH or 18 AH batteries Battery charger may be disabled via DIP switch for applications larger batteries and external battery charger blocks accommodate up 12 AWG Removable wire Works with any UL 864 FACP which utilizes an industry standard notification circuit Optional devices include addressable control monitor and relay and power supervision relay EOLR 1 and Codes PSE Series comply with the following standards NFPA 72 National Fire Alarm Code UL 864 Standard for Control Units for Fire Alarm Systems NAC mode 10th Edition UL 1481 Power Supplies for Fire Alarm Systems 2009 when using SEISKIT MULTI 1 CBC 2007 when using SEISKIT MULTI 1 Listings and Approvals listings and approvals apply to the modules specified in this In some cases certain modules or applications may not listed by certain approval agencies or listing may be in process factory for latest listing status UL Listed S635 S674 ULC Listed S635 PSE 6 10C CSFM Approved 7315 0028 0513 FDNY Approved FM Approved 3 10 2021 Page 1 of 2 AC Power PSE 6 C 120 VAC 50 60 Hz 5.0A maximum PSE 10 C 120VAC 50 60 Hz 6.2 A maximum PSE 6E 240 VAC 50 60 Hz 2.7A maximum PSE 10E 240 VAC 50 60 Hz 3.5A maximum Wire Size 12 14 AWG with 600 V insulation Input Circuit Trigger Input Voltage 9 to 32 VDC Trigger Current 2.0 mA 16 32 V Per Input 1.0 mA 9 16 V Contact Rating 4 A at 24 VDC Circuits 24 VDC filtered regulated PSE 6 TB8 TB9 1A Regulated 3A special applications TB10 0.3A Regulated 3A special applications PSE 10 TB8 TB11 1.5A Regulated 3A special applications 0.3A Regulated 3A special applications 6.0 A PSE 6 or 10.0 A PSE 10 maximum total continuous cur for all outputs Power Battery Charging Circuit Supports lead acid batteries only Float charge voltage 27.6 VDC Maximum current charge 1.5 A Maximum battery capacity 18 AH inside cabinet Maximum battery charging capacity 33 AH external cabinet Dimensions 20.0 x 14.5 x 3.5 cm 50.8H x 36.83W x Weight with two 7Ah batteries is 24 pounds 10.9 kg with two AH batteries is 39 pounds 17.7 kg Information 6.0 A 120 VAC remote charger power supply in a lockable enclosure Same as above ULC listed model Same as PSE 6 with red enclosure 6.0 A 240 VAC remote charger power supply in a lock metal enclosure 10.0 A 120 VAC remote charger power supply in a lock metal enclosure Same as above ULC listed model Same as PSE 10 with red enclosure 10.0 A 240 VAC remote charger power supply in a lock metal enclosure Optional Class A output converter module Addressable Control Module for one Class B or Class A of supervised polarized Notification Appliances Notification Circuit option requires external 24 VDC to power notifica appliances Addressable relay module containing two isolated sets of contacts which operate as a DPDT switch Addressable Monitor Module for one zone of normally open initiating devices Includes plastic cover plate and end resistor Module may be configured for either a Class B or A IDC Dual Monitor Module Same as FMM 1 except it provides inputs for Class B wiring only Provides two monitored inputs and two Form C relays in Class B wiring only Six circuit supervised control module Six Form C relay control module 12 24 VDC end of line relay for monitoring four wire detector power Battery 12 volt 7.0 AH 5 pack two required see Series data sheet DN 6933 Battery 12 volt 18AH 2 pack Battery 12 volt 33AH Seismic kit for the PSE Series Includes bracket hardware for two 7AH or two 18AH batteries Clintonville Road CT 06472 document is not intended to be used for installation purposes try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice and System Sensor are registered trademarks of Honeywell Inc Wheelock is a registered trademark of Cooper Tech Company Gentex is a registered trademark of Gentex Corpora AMSECO is a registered trademark of Potter Electric Signal LLC ANSI is a registered trademark of the American National Institute Inc by Honeywell International Inc All rights reserved Unauthorized of this document is strictly prohibited of Origin USA

Related Files