Notifier SpectrAlert® Advance Selectable Output CHRA, CHWA Chimes and CHSRA, CHSWA Chime Strobe

File Preview
File Preview
Click below to download for free

Text Preview

SpectrAlert Advance Output CHRA CHWA Chimes CHSRA CHSWA Chime Strobe Advance selectable output chimes and chime are private mode notification appliances used to alert personnel to investigate possible emergency situations to take appropriate action Security guard and nurse work are ideal locations for chime products Advance chimes and chime strobes are rich with guaranteed to cut installation times and maximize The SpectrAlert Advance series of notification appli is designed to simplify your installations with features as plug in designs instant feedback messages to correct installation of individual devices and seven candela settings for chime strobes specifically when installing Advance products first a universal mounting plate to a four inch 10.16 cm four inch octagonal single gang or double gang junc box connect the notification appliance circuit wiring to the terminals on the mounting plate attach the chime or chime strobe to the mounting plate inserting the product tabs in the mounting plate grooves device will rotate into position locking the product pins the mounting plate terminals The device will temporarily in place with a catch until it is secured with a captive screw Advance products allow you to choose 12 or 24 volts At 24 volts 15 15 75 30 75 95 110 or 115 candela by of rear mounted slide switch and front view window Chime tones and volume by way of rotary switch Plug in design Shorting spring on mounting plate for pre installation conti Captive mounting screw Torx screw for tamper resistance Field selectable candela settings 15 15 75 30 75 95 Automatic selection of 12 or 24 volt operation at 15 and 15 check 115 candela Minimal intrusion into the backbox Rotary switch for tone selection Two volume settings Electrically compatible with existing SpectrAlert products Specifications Advance chimes and chime strobes shall mount to standard 4.0 x 4.0 x 1.5 10.16 x 10.16 x 3.81 cm back 4.0 10.16 cm octagonal backbox single gang 2.0 x x 1.875 5.08 x 10.16 x 4.763 cm backbox or double backbox A universal mounting plate shall be used for products The notification appliance circuit wiring terminate at the universal mounting plate Also SpectrA Advance products when used with the Sync DN 60029 A J 75 Devices CHWA CHSRA accessory shall be powered from a non coded notifi appliance circuit output and shall operate on a nominal or 24 volts When used with the Sync Module 12 rated notification appliance circuit outputs shall operate 9 and 17.5 volts 24 volt rated notification appliance outputs shall operate between 17 and 33 volts Indoor Advance products shall operate between 32 and 0 and 49 from a regulated DC or full wave recti unfiltered power supply Chime strobes shall have field candela settings of 15 15 75 30 75 95 110 and COMBINATION chime strobe shall be a System Sensor SpectrAlert Model listed to CAN ULC S525 and S526 chime strobe shall comply with the Americans with Dis Act requirements for visible signaling appliances at 1 Hz over the strobe entire operating voltage The strobe light shall consist of a xenon flash tube and lens reflector system The chime shall have two options and an option to switch between a temporal and a non temporal continuous pattern These are set by a multiple position switch MODULE module shall be a System Sensor Sync to ULC 464 and shall be approved for fire protective ser The module shall synchronize SpectrAlert strobes at 1 and chimes at Temporal 3 Also while operating the the module shall silence the chimes on chime strobe over a single pair of wires The module shall mount to 4.688 x 4.688 x 2.125 11.906 x 11.906 x 5.398 cm back The module shall also control two Style Y Class B cir or one Style Z Class A circuit The module shall multiple zones Daisy chaining two or more syn modules together will synchronize all the zones control The module shall not operate on a coded power 2 21 07 Page 1 of 4 Specifications Standard operating temperature 32 to 120 0 to Humidity range 10 to 93 non condensing indoor Strobe flash rate 1 flash per second Nominal voltage regulated 12 VDC FWR or regulated 24 NOTE Full Wave Rectified FWR voltage is a time varying power source that is used on power supply and panel outputs Operating voltage range 8 V to 17.5 V 12 V nominal or V to 33 V 24 V nominal NOTE CHS products will at 12 V nominal only for 15 cd and 15 75 cd terminal wire gauge 12 to 18 AWG 3.31 to 0.821 Chime strobe dimensions including lens 5.6 H x 4.7 x 2.5 D 14.2 cm H x 11.9 cm W x 6.4 cm D Chime dimensions 5.6 H x 4.7 W x 1.3 D 14.2 cm H x cm W x 3.3 cm D Listings and Approvals listings and approvals below apply to SpectrAlert Advance Output Chimes and Chime Strobes In some cases modules may not be listed by certain approval agen or listing may be in process Consult factory for latest list status ULC Listed file S4011 FM approved Information Chime red Chime white Chime strobe red Chime strobe white Backbox skirt wall red Backbox skirt wall white Draw ULC Maximum mA RMS Pattern dB Out cd cd cd cd cd cd 17.5 Volts 33 Volts 1 Second Chime HIGH 1 Second Chime LOW 1 4 Second Chime HIGH 1 4 Second Chime LOW Temporal Chime HIGH Temporal Chime LOW 5 Second Whoop HIGH 5 Second Whoop LOW One Time Chime 1 Second Chime HIGH 1 Second Chime LOW 1 4 Second Chime HIGH 1 4 Second Chime LOW Temporal Chime HIGH Temporal Chime LOW 5 Second Whoop HIGH 5 Second Whoop LOW One Time Chime cd cd cd 2 of 4 Canadian DN 60029 A 2 21 07 Selection tone selection is accomplished by using the rotary switch on the back the product The current draw and sound measurements for various tones are listed below Patterns Rate Out Chime Chime Chime Chime Chime Chime Whoop Whoop Test Chime 17.5 Volts 33 Volts Current Draw Maximum mA RMS Pattern Chime Chime Chime Chime Chime Chime Whoop Whoop Test Chime Pattern Chime Chime Chime Chime Chime

Related Files