Notifier XAS-1 & XAS-2 XAS Smoke Detector

File Preview
File Preview
Click below to download for free

File Data

Name notifier-xas-1-xas-2-xas-smoke-detector-9260341587.pdf
Type PDF
Size 877.02 KB
Downloads

Text Preview

XAS 1 XAS 2 Smoke Detector XAS Air sampling Smoke Detection system provides a detection solution to meet unique needs of challenging found in typical commercial and industrial sites XAS solution is well suited to installations where access to monitored areas is restricted and provides tamper proof unobtrusive detection The ability to mount the device out the protected area makes it ideal for use in applications as correctional facilities transformer vaults cable tun elevator shafts and HVAC ducts XAS systems actively draw air from the protected area sampling holes in a pipe network Sampled air is then before being analyzed by the analog point detectors in the systems The XAS system is available in a zone Order as XAS 1 US or dual zone Order as XAS and can be used with one or two detectors per system systems utilize a high performance aspirator and pro flow monitoring circuitry Air flow level is displayed a ten element bar graph that can be adjusted for high and flow thresholds and flow failure is reported as a device via relays to the monitoring system Compatible with ONYX FireWarden and CLIP series Fire Alarm Panels Single or dual zone fire detection Multiple piping options Multiple detection strategies 164 ft 50 m max per unit 50 ft 15 m max per flexible tube Microprocessor controlled High performance aspirator Field serviceable air filter Adjustable aspirator speed with airflow monitoring systems may be configured for a number of detection including single or dual addressable area detection redundant detection coincident or double knock detection display and programmer DETECTORS FSP 851 Addressable photo detector FSA 851A Addressable photo detector for use with ULC B501 B501A Flangeless mounting base NP 100 Addressable photoelectric detector ELECTRICAL SPECIFICA Range 15 32 volts DC peak Current max avg 300 24VDC one every five seconds with LED enabled Device Current max 6.5mA 24 VDC The spot point detectors are powered from the Signaling Circuit SLC ELECTRICAL SPECIFICATIONS VOLTAGE VDC nominal ULC S527 listed power supply S24829 approved WHD in x 12.6 in x 6.5 in 259 mm x 321 mm x 166 mm 350 mA max 680 mA 7.27 lbs 3.3 kg 7.5 lbs 3.4 kg CONDITIONS Operating Temperature range 32 to 120 0 49 Air 32 to 120 0 to 49 10 to 93 noncondensing INLET PIPE both metric and American standard pipe sizes 25mm 1.05 in Pipe in I D 21mm 5 23 17 Page 1 of 2 Dual Zone water trap kit Baffles for Spot Detector Package of 10 PARTS Replacement Filter Element FT series pack of 10 20 ppi Black IAS 1 Display Kit IAS 2 Display Kit IAS Aspirator EN IAS Cover removal tool IAS Corner Studs Pack of 4 IAS Flow Sensor Assembly and Approvals listings and approvals apply to the modules specified in document In some cases certain modules or applications not be listed by certain approval agencies or listing may in process Consult factory for latest listing status UL ULC S24829 tubing in O D 19mm NETWORK Length Up to 164 ft 50 m total per device Tube Length Maximum 50 ft 15m RATING Wiring Enclosure Enclosure IP65 filter filter optional MONITORING AND REPORTING and Low programmable flow limits 10 programmable speeds 250 Pa OUTPUTS 1 fault relay output 2 fault relay outputs WIRING Terminals to 10 AWG 0.9 to 5.5 sq mm solid to 12 AWG 0.6 to 3.5 sq mm stranded information When ordering the XAS add US after the part number Air sampling Smoke Detector with single zone Air sampling Smoke Detector with dual zone Addressable photo detector Addressable photo detector for use with ULC Flangeless mounting base Addressable photoelectric detector Single Zone Duct Installation Kit Dual Zone Duct Installation Kit 50 Flexible Dual Tube 25 Flexible Dual Tube 50 Flexible Single Tube 25 Flexible Single Tube 18 Probe Kit one 18 sample one 8 exhaust 36 Probe Kit one 36 sample one 8 exhaust 60 Probe Kit one 60 sample one 8 exhaust 18 Probe Kit two 18 sample one 8 exhaust 36 Probe Kit two 36 sample one 8 exhaust 60 Probe Kit two 60 sample one 8 exhaust Single Zone water trap kit by Honeywell International Inc All rights reserved use of this document is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Notifier Phone 203 484 7161 FAX 203 484 7118 2 of 2 DN 60790 D cid 129 5 23 17

Related Files