Paradox 616, 626, 636 and 646 Keypads User's Manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | paradox-616-626-636-and-646-keypads-user-s-manual-0895732416.pdf |
---|---|
Type | |
Size | 761.75 KB |
Downloads |
Text Preview
616 626 636 646 Manual OF CONTENTS BASIC OPERATION 2 ACCESS CODES 4 ARMING DISARMING 6 PANIC ZONES 13 KEY ACCESS PROGRAMMING 14 ADDITIONAL FEATURES 15 TROUBLE DISPLAY 16 FIRE ALARM OPERATION 18 SYSTEM MAINTENANCE 20 SYSTEM CHECKLIST 21 Keypads 1 BASIC OPERATION Esprit 616 626 636 and 646 keypads all in the same way but display the visual differently VISUAL FEEDBACK numbers symbols lights and keys on the keypad the status of your system as described 1 Overview of the 616 626 Keypads User Manual 2 Overview of the 636 646 Keypads Keypads 3 opened or breached ZONES Esprit control panel can support up to 24 zones a zone key will light up on the keypad For if zone 5 were to open the 5 key will light up the keypad The Esprit keypads will show the of the zones through keys 1 to 12 By default 1 to 12 will display the status of zones 1 to 12 the 2ND button and keys 1 to 12 will now the status of zones 13 to 24 respectively PARTITIONING Esprit system is equipped with a partitioning that can divide your alarm system into two areas System A and System B User access can arm or disarm one system or both systems In partitioning mode when System A armed the STAY key flashes If System B is the AWAY key flashes If both systems are both of these keys will be flashing ACCESS CODES PROGRAMMING USER CODES addition to the master code the Esprit control can be programmed to accept up to 48 user User Manual Avoid programming simple or access codes such as your number address or codes such 1234 create or modify access codes follow the steps in section2.2 The master code and user are identified by a 2 digit number CREATING USER CODES Press ENTER and then enter your master code 474747 or user 1 code You will hear beep and the ENTER key will Enter the two digit number 01 48 for the code you wish to program or 00 to change master beep and the ENTER key will stay You will hear Key in 4 or 6 digit user access code and press The beep will be heard The ENTER key will flash You may programming other user codes or CLEAR to exit programming mode 2ND key flashes if location is empty code programmed Keypads 5 DURESS CODES last user code user 48 can be programmed to a code If you are forced to arm or your system under threat a duress code can entered to produce a silent alarm at the monitoring Check with your installer to see if this option active on your system DELETING A USER CODE do I delete a user code Press the ENTER key Enter your MASTER CODE default 474747 Enter the 2 digit CODE NUMBER 01 48 to be deleted Press the 2ND key Press the ENTER key If you wish to delete another user code repeat steps 1 5 If you wish to exit press the CLEAR key ARMING DISARMING EXIT DELAY entering a valid arming sequence an exit delay will provide you with time to exit the protected before the system arms The keypad may beep the exit delay User Manual REGULAR SYSTEM ARMING do I Regular Arm the system The green light must be ON in order to arm system Enter your User Code the Confirmation beep the light and the and AWAY buttons will begin to flash The exit timer will begin the countdown to arming STAY ARMING arming allows you to remain in the protected while arming the system perimeter only such as doors and windows do I Stay Arm the system Press the STAY button Enter your User Code the Confirmation beep the light and the and AWAY buttons will begin to flash The exit timer will begin the countdown to arming ONE TOUCH ARMING touch system arming no code required Check your installer if these features are enabled Key 10 Regular Arming the light is on pressing key 10 for 2 seconds automatically arms the system Keypads 7 section3.3 on page7 Key STAY 11 Stay arming refer of stay arming Press the STAY 11 key for 2 seconds This will automatically the system an DOUBLE STAY ARMING Stay Arming and during the exit delay press hold the STAY 11 key to switch any delayed to zones Regular arming cancels stay arming FAST EXIT WHILE IN STAY MODE Fast Exit and Stay Arm exit the already Stay armed premises and remain armed press key STAY 11 for two seconds system will switch to exit delay mode flashes At the end of the exit delay period the will return to arming mode Fast Exit and Regular Arm exit the already Stay armed premises and switch regular arming press key 10 for two seconds system will switch to regular arming keys 11 12 flash with an exit delay At the end of the delay period the system is regular armed User Manual KEYSWITCH ARMING keyswitch can be used to arm your system If an is generated in your system or a zone that has been defined as a Stay zone is opened after arming the system can only be disarmed from keypad if keyswitch is defined as arming MANUAL BYPASS ARMING feature arms the system while bypassing zones wish to leave unarmed do I Manually Bypass Arm the system Press the BYP button and then enter your User Code BYP key will illuminate as well as any zones that already been bypassed Enter the number of the zone s you wish to bypass a bypassed zone enter the zone num of the bypassed zone Press ENTER Arm the system using desired method BYP key will remain illuminated to indicate that are bypassed zones using the recall feature you can reinstate latest zone bypass instructions saved in memory BYP in Step 2 see above and the previous status will be re established FORCE AWAY ARMING arm the system rapidly without waiting for the Keypads 9 light for all zones to close use Force arming Open zones will not be protected but be armed as soon as they are closed do I Force Arm the system Press the AWAY button and then enter your User AWAY key will flash ARMING BOTH SYSTEMS SIMULTANEOUSLY your code has access to both systems do I Arm Systems A and B simultaneously Enter your Access Code STAY AND AWAY key will flash The light also begin to flash and the exit timer will begin to ARMING SYSTEM A AND B SEPARATELY your Access Code has access to System A do I arm System A Press the STAY key Enter your Access Code STAY key will flash The light will also to flash and the exit timer will begin to count your Access Code has access to System B User Manual do I Disarm System B Press the AWAY key Enter your Access Code AWAY key will flash The light will also to flash and the exit timer will begin to count section3.3 on page7 STAY ARMING SYSTEM A refer of stay arming Press the STAY 11 key for 2 seconds With your system partitioned System A will be Stay armed when the STAY 11 is pressed an MOVEMENT SUPERVISION FEATURE panel can be progr