Potter 550-0671-AAE PAD200-IB-RB-SB-Series

File Preview
File Preview
Click below to download for free

File Data

Name potter-550-0671-aae-pad200-ib-rb-sb-series-6058497312.pdf
Type PDF
Size 1.86 MB
Downloads

Text Preview

550 0671 000 Bases PAD100 RB and PAD100 SB PAD100 PHD PAD200 PD PAD200 PHD PAD200 PCHD PAD100 HD and PAD100 CD Field Wiring Diagram s for PAD100 RB field wiring diagrams for the Signaling Line Circuit SLC FIGURE 4 The SLC NFPA wiring Class B A and X FACP SLC NO Base SLC C NO Base SLC 4 Wiring Class B Using PAD100 RB NFPA Class B SLC S S Wiring using the PAD100 RB base FIGURE 4 Class A arrangement two separate conductors return from the last detector base a listed compatible Fire Alarm Control Panel FACP In Class X it is required to PAD100 IB Addressable Isolator Bases The typical field diagram is in Field Diagram s for PAD100 IB section of this manual Field Wiring Diagram s for PAD100 SB field wiring diagrams for the Signaling Line Circuit SLC FIGURE 5 The SLC NFPA wiring Class B A and X PWR Base SLC PWR Base SLC FACP SLC 5 Wiring Class B Using PAD100 SB ensure proper installation of the detector head to the base wires shall be properly at the time of installation NFPA Class B SLC S S Wiring using the PAD100 SB base FIGURE 5 In Class A arrangement two separate conductors would return from the last base to a listed compatible Fire Alarm Control Panel FACP In Class X it is to use PAD100 IB Addressable Isolator Bases The typical field diagram is Field Wiring Diagram s for PAD100 IB section of this manual Wiring Instruction When using PAD100 Bases observe the correct polarity of SLC wiring THE WIRING TO BE USED SHALL BE IN ACCORDANCE WITH THE Break wire runs to provide supervision for connections made to each pair Base Mounting PAD100 RB and PAD100 SB should be mounted directly on the box The PAD100 IB PAD100 RB and PAD100 SB mounting holes are for a single gang 4 octagon or 4 square box Use a box for each base run the power circuit to all base locations OF ARTICLE 300.3 B OF THE NATIONAL ELECTRICAL CODE 70 AS WELL AS ARTICLE 210 EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE FIRE PROTECTION ASSOCIATION STANDARD 72 Number 550 0671 Description document provides instructions for mounting and wiring the Detector Bases PAD100 RB and PAD100 SB The following detectors are compatible Detector Bases PAD100 IB PAD100 RB and PAD100 SB PAD200 PD PAD100 PD PAD200 PHD PAD100 PHD Photoelectric Smoke Heat Detector PAD200 PCD Smoke CO Detector Smoke CO Detector Heat Detector PAD200 PCHD Detector PAD100 HD PAD100 CD Monoxide Detector Field Wiring Diagram s for PAD100 IB field wiring diagrams for the Signaling Line Circuit SLC FIGURE 1 SLC supports NFPA wiring Class B A and X Smoke Detector SLC2 Base SLC2 SLC2 Base FACP SLC BASE BASE MODULE AREA TO BE ISOLATED BY THE SHORT CIRCUIT CIRCUIT 1 Wiring Class B Using PAD100 IB NFPA Class B SLC S S Wiring using the PAD100 IB base FIGURE 1 In A FIGURE 2 arrangement two separate conducts would return from the last base to a listed compatible Fire Alarm Control Panel FACP In X it is required to use PAD100 IB Addressable Isolator Bases FIGURE 3 BASE BASE AREA TO BE ISOLATED BY THE SHORT CIRCUIT CIRCUIT IB NEXT TO A FACP SHALL BE INSTALLED 20 FEET FROM THE TERMINAL OF THE FACP 2 Wiring Class A Using PAD100 IB AREA TO BE ISOLATED BY THE SHORT CIRCUIT CIRCUIT IB NEXT TO A FACP SHALL BE INSTALLED 20 FEET FROM THE TERMINAL OF THE FACP 3 Wiring Class X Using PAD100 IB 12 to 22 AWG conductors to connect to terminals of bases It is recommended the SLC conductors be color coded to avoid wiring errors and assist in system Improper SLC connections may prevent the system from normally Disconnect power to the SLC until the detectors are installed Wire the detector bases according to Field Wiring Diagrams Use the dip switches SECTION 11 to set address es 1 127 for each detector THE PAD100 IB PAD100 RB AND PAD100 SB OBTAINS THE ADDRESS FROM THE DETECTORS AND THE PAD100 MODULES MUST HAVE INDIVIDUAL To install the detector head onto the base match the detector heads to the using the alignment feature and twist clockwise until the detector heads into place FIGURE 6 DETECTOR HEAD the two screws the base to bracket the detector bracket the back box using the screws 6 Assembly of Detector power to the FACP After all detector heads addressable bases and modules have been installed Test the detectors as described in the Testing Section of this manual DO NOT INSTALL DETECTOR HEADS UNTIL AREA HAS BEEN CLEANED TO REMOVE CONSTRUCTION DEBRIS DUST ETC REQUIRED BY NFPA 72 Spacing Limitations REFER TO NFPA 72 FOR SPECIFIC INFORMATION REGARDING DETECTOR MOUNTING LOCATION AND SPECIAL APPLICATIONS PAD200 PD PAD100 PHD PAD200 PCD PAD200 PCHD and PAD200 Photoelectric Smoke Detector PAD200 PD PAD200 PCD PAD200 PCHD PAD100 PHD and PAD200 are ANSI UL listed on maximum 30ft spacing limitation with alarm set point 135O 174O F on smooth ceiling Refer to NFPA 72 for specific information detector spacing placement and special applications Heat Detector ANSI UL listed spacing limitations of PAD100 HD smooth ceiling are on alarm set point Set Point of Rise Spacing Temperature Spacing to 174O F to 79O C to 185O F to 85O C to 160O F to 71O C 60 ft 60 ft 15 ft 15 ft 70 ft 70 ft Testing shall be performed periodically to determine if each detector operates Detectors will offer maximum performance when tested in compliance NFPA 72 REFER TO FIRE ALARM CONTROL PANEL FACP MANUAL FOR OF DIRTY VALUE READ PRINT ALARM SIMULATION AND WALK TEST Testing PAD100 PD PAD200 PD PAD100 PHD PAD200 PHD PAD200 PCD PAD200 PAD100 HD and PAD100 CD are under normal conditions in standby mode alarm indicator LEDs will pulse approximately once every 4 seconds WHEN A PANEL IS CONFIGURED TO NOT FLASH LEDS THE LEDS ON THE WILL NOT FLASH AT ANY TIME Testing Value Read Print sensitivity drift value Dirty Value of the smoke detector can be checked at the The Dirty Value can be read and printed out at the FACP DETECTOR COMPENSATES SENSITIVITY UNTIL LIMIT OF WHEN COMPENSATION RATE REACHES LIMIT A TROUBLE WILL BE INDICATED ON THE FACP Testing BE SURE TO DIS ENGAGE ALL ALARM SIGNAL SERVICES RELEASING AND EXTINGUISHING SYSTEMS PRIOR TO PERFORMING THE TEST EXCEPT AUTOMATIC TESTING BY THE FACP BE SURE TO THESE SYSTEMS WHEN ALL TESTING IS COMPLETE Test FACP must be placed into Walk Test Mode and follow the steps below the appropriate steps outlined below for the detector that is to be tested FAILURE TO ALARM DURING A TEST INDICATES A DEFECTIVE REPLACE DETECTOR IMMEDIATELY PAD100 PD PAD200 PD PAD200 PCD PAD200 PCHD PAD100 PHD and Smoke Detectors Use the Home Safeguard Model 25S or SDi Smoke Centurion as acceptable the Authority Having Jurisdiction AHJ Do not heat over 210oF 98.9oC PAD100 PHD PAD200 PCHD PAD200 PHD and PAD100 HD Heat Detectors TAKE CARE DURING THE HEATING OF THE DETECTOR TO AVOID THE PLASTIC HOUSING Use of a low powered heat gun is acceptable Maintain a minimum of 1 foot between the detector and the heat gun Heat the detector for a minimum of 10 seconds PAD100 CD PAD200 PCD PAD200 PCHD Carbon Monoxide Detector Use Home Safeguard Model HO CO2 Aerosol with Home Safeguard Model Head VT1 or the SDI Solo C6 Aerosol with SDI Solo 330 Dispenser as to the Authority Having Jurisdiction AHJ will indicate with alarm

Related Files